Download Centronic TimeControl TC511A
Transcript
Operating Instructions Problem Cause The sun and twilight parameters cannot be changed, and/or are not displayed. No light sensor is Check the light sensor, connected or the light connecting cable and sensor, and/or the con- connector plug. necting cable is faulty. Roller shutter does not move to the end limit. 1. The set running time is not long enough. 2. No end limit position is set. Remedy 1. Adjust the running time in the function menu. 2. Set the end limit position using the setting menu PROG1/2. Transmission control light flashes. Batteries are running low. The transmitter does not react after the batteries have been changed. Power supply has been Press the RESET butinterrupted for too long. ton. Check settings. The display is showing “BATTERY”. Battery power is low. 62 Insert new batteries. Replace battery.