Download DMM 230 - Multimetrix
Transcript
Chapter II 1. Set the function switch to the Ω position. 2. Insert the black test lead banana plug into the negative COM terminal. 3. Insert the red test lead banana plug into the positive + terminal. 4. Press the MODE key to indicate "Ω". 5. Apply the test probes to the points of the circuit to be tested. It is best to disconnect one side of the part to be tested so the rest of the circuit will not interfere with the measurement. The value measured is displayed. 3.8 Continuity test To avoid electric shock, never measure continuity on circuits or wires that have voltage on them. 1. Set the switch to the Ω position. 2. Insert the black lead banana plug into the negative COM terminal. Insert the red test lead banana plug into the positive + terminal. 3. Press the MODE key to display and "Ω" on screen. 4. Apply test probes to the points of the circuit to be tested. 5. All resistance higher than 100 Ω will stop the instrument’s sound alert. If the circuit is open, “OL” is displayed on screen. ) The temperature probe is fitted with a type K mini connector. A mini connector to banana connector adaptor is supplied for connection to the input banana terminals. 3.9 Diode test To avoid any risk of deterioration, remove power from the circuit to be tested before making any diode measurements. 1. Set the function switch to the Ω position. 2. Insert the black test lead banana plug into the negative COM terminal and the red test lead banana plug into the positive + terminal. 3. Press the MODE key to display on screen. 26 and V DMM230