Download wireless smoke detector sd90
Transcript
WIRELESS SMOKE DETECTOR SD90 OWNER’S MANUAL For use with Haibrain security systems of the types: • • • • • • SafeGuard TotalGuard HomeGuard MS8000 Security System MS9470, MS9770, MS9970 Security System Protector 28 Home Automation Controller SC2200, SC2700, SC2800, SC9000 Please read these instructions carefully and completely before initial activation; they contain information for the correct installation of this wireless smoke alarm. SAFETY WARNINGS • • • • • • • • • The SD90 is a smoke alarm that is exclusively designed for use in the home. The smoke alarm emits a piercing sound when smoke is detected. Ensure that the smoke alarm is positioned in an area where the built-in siren can be clearly heard, also when you are sleeping. Place additional smoke alarms if necessary. You can also use the smoke alarm with Haibrain security systems to add extra functionality. In this way it is possible to receive a telephone warning if the smoke alarm is activated. Please be aware: the manufacturer is not responsible for use of this extra function. Test your smoke alarm once a month. To prevent short circuits, this product should only be used inside and only in dry spaces. Do not expose the components to rain or moisture. Do not use the product close to a bath, swimming pool etc. Do not expose the components of your systems to extremely high temperatures or bright light sources. Do not open the product: the device contains live parts. The product should only be repaired or serviced by a qualified repairman In case of improper usage or if you have opened, altered and repaired the product yourself, all guarantees expire. Haibrain does not accept responsibility in the case of improper usage of the product or when the product is used for purposes other than specified. Haibrain does not accept responsibility for additional damage other than covered by the legal product responsibility. Do not use cleaning products when cleaning the alarm. Clean the alarm with a dry or slightly damp cloth. Batteries: keep batteries out of the reach of children. Dispose of batteries as chemical waste. Never use old and new batteries or different types of batteries together. Remove the batteries when you are not using the system for a longer period of time. Check the polarity (+/-) of the batteries when inserting them in the product. Wrong positioning can cause an explosion. TABLE OF CONTENTS 1. 2. 3. 4. 5. 6. 7. General and function Application Positioning Installation Preparing for use Registering the smoke detector with the SC9000 base station of the SafeGuard / TotalGuard Registering the smoke detector with the base stations of the types MS9470, MS9770, MS9970, SC2200, SC2700, SC2800, Protector 28 8. Registering the smoke detector with the base station of the type Homeguard MS8000 9. What happens when the alarm goes off? 10. Changing the battery SD90 4 4 4 5 5 5 6 6 6 6 3