istr_P560_VARIOmat_09_14:istr_P444 28/08/14 14.29 Pagina 20 18. Replacing the fuse In case of fuse intervention,disconnect power supply from the frequency converters, remove the screws and the cover of the frequency converter. Pull out the spare fuse, remove the two screws and the electrical board protection, pull out the faulty fuse and replace with the spare fuse, reinstall the protection tighten the two screws and at the end reinstall the cover of the frequency converter and tighten all the screws. P531 If the operation is working correctly, after some seconds the frequency converter will turn on automatically. Restart the frequency converters and check if the pumps, the frequency converters and the system are working properly. 15. Alternation of the running continuously To remove the electrical board protection and to access to the faulty fuse unscrew the 2 screws. pump 19. Accessories In the case which, for any reason, one or more pumps is working continously without alternating with the pumps in stand-by, to guarantee an homogeneus wear of the pumps. Every sixty minutes of continuous duty of one pump the system automatically forces the change of the stand-by pump. The change of the pump respects the alternating sequence of the converters. 19.1. RA 100 Control panel for remote alarm Dimensions: 110x150x70 Power supply: 220-230 V single-phase Signals all pump assembly malfunctions detected: - No water intake. - Assembly malfunction. - Converter failure. 5-Watt flashing red light plus 75 dB – 3600 Hz acoustic alarm, for use in areas loud noise, positioned in such way as to be visible from a distance. The control panel is fitted to an energized panel led and an alarm reset pushbutton. 16. Cascade anti-lock function In the case that, for any reason, one or more pumps remains stopped for 24 consecutive hours the frequency converter will start the motor of the pump for approximately 5 seconds (anti-lock function) without modification on the alternating sequence of the system. 17. Use of megaohmeter RA 100 Megging of an installation incorporating the frequency converter is not allowed, because the electronics may be damaged. If megging is necessary, disconnect the frequency converter and use the megaohmeter directly on the terminal box of the pump. 20. Disposal Observe the local regulations and dispose of any control gear accordingly. This product contains electrical and electronic components and should be disposed of accordingly. 20