Step 3 – Plugging in the AC Power Cord ENGLISH 4. Circle the tie of the Retainer around the power cord and into the locker of the Retainer. Users may now connect the AC power cord to an electrical outlet (preferably one that is grounded and surge protected) and into the rear of the switch. Figure 2-4. Circle around the power cord 5. Fasten the tie of the Retainer until the power cord is secured. Figure 4. Plugging the switch into an outlet Power Failure As a precaution, the switch should be unplugged in case of power failure. When power is resumed, plug the switch back in. Figure 2-5. Secure the power cord Connecting DC power to the DC power supported Switch Rack Installation Follow the instructions below to connect the DC power supply of a DC powered switch to a DC power source. The switch can be mounted in an EIA standard size 19-inch rack, which can be placed in a wiring closet with other equipment. To install, attach the mounting brackets to the switch’s side panels (one on each side) and secure them with the screws provided (please note that these brackets are not designed for palm size switches). Figure 3-1. Attaching the mounting brackets Then, use the screws provided with the equipment rack to mount the switch in the rack. Figure 5. Power connections attached to contacts on assembly Firmly attach the DC power to the negative and positive contacts on the wiring assembly. • The negative pole (-) connects to the -48V contact. • The positive pole (+) connects to the -48V Return contact. • If available, the earth ground may be connected to center contact post. • Tighten the contact screws so the connection is secure. Figure 3-2. Installing the switch in a standard-sized equipment rack 3