Hardware Preparation and Installation Table 2-2 Environmental Requirements (continued) Requirement Operating Non-Operating Free Fall 1,200 mm (Packaged) /all edges and corners 1.0m (Packaged) per ETSI 300 019-2-2 (Blade level packaging) 25 mm (unpackaged) per GR63-CORE 1. When operated in 55C ambient temperature and depending on the shelf's cooling capabilities the board is plugged into, the SAS hard disk surface temperature exceeds the specified maximum limit of 60C. 2. The SAS drives can meet this max temperature range of non-operating. 3. The vibration tolerance can be further limited due to the hard disk you are installing on the blade. Please refer to the respective datasheet for further information. 2.3.2 Power Requirements Make sure that the blade is used in an AdvancedTCA shelf connected to -48VDC up to -60VDC, according to Telecommunication Network Voltage (TNV-2). A TNV-2 circuit is a circuit whose normal operating voltages exceed the limits for a safety-extra-low-voltage (SELV) under normal operating conditions, and which is not subject to overvoltages from telecommunication networks. Table 2-3 lists the power requirements for the ATCA-7350. Table 2-3 Power Requirements Requirement Operating Rated Voltage -48VDC to -60VDC US and Canada: -48VDC Operating Voltage -39.0VDC to -72VDC US and Canada: -39.0 to -60VDC Input Current 3.75A at 48V Power Dissipation 200W (max) 150W (typical) ATCA-7350 Installation and Use (6806800G59G) 31