Download pdf, deutsch - TR
Transcript
Emergency Message 10 Emergency Message Emergency messages are triggered by the occurrence of a device internal malfunction and are transmitted from the concerned application device to the other devices with highest priority. Emergency Message Byte Contents 0 1 Emergency Error Code Object 1003h, Byte 0-1 2 3 4 5 6 7 Error Register Object 1001h 0 0 0 0 0 COB-Identifier = 080h + Node-ID If the measuring system detects an internal error, an emergency message will be transmitted with the error code of object 1003h (pre-defined error field) and the error register object 1001h. If the error disappears, the measuring system transmits an emergency message with error code "0" (reset error / no error) and error register "0". TR-Electronic GmbH 2006, All Rights Reserved Page 106 of 112 Printed in the Federal Republic of Germany TR - ECE - BA - DGB - 0038 - 04 10/17/2014