Download USER'S GUIDE
Transcript
USER’S GUIDE September 2009 Contents Part 1 Structure and Function (P3-P18) Part 2 Operating Instructions (P19 (P19-P189) P189) Step 1: Starting Instrument Wizard (P20-P54) Power off within 48 hours/over 48 hours Step 2: Loading Reagent, Samples & Reaction Cups (P55-P122) Perform T3 & T4 by 10 Samples Step 3: Adding Patient Information (P123-P130) Step 4: Viewing Testing Status(P131-P144) Step 5: Viewing Testing Report (P145-P167) Step 6: Closing Instrument Wizard(P168-P189) Reuse in 48 hours/after 48 hours Part 1 Structure and Function QQ-120 Automated Chemiluminescence System Reagent g position for Enzyme y Conjugate Sample position for Calibrator, QC, Sample and Reaction Cup Substrate A and Substrate B Reagent cooling subsystem Reagent probe Sample probe Washing cup for reagent probe Washing cup for sample probe Automatic shaker for Reaction Cup incubation subsystem, subsystem under the reagent position Entrance for incubation subsystem Buffer bottle Probe wash solution Cup wash solution Substrate dispensing needle Aspirating needle Dispensing needle & aspirating needle (to dispense/aspirate washing buffer into each tube) Guide rail for waste cup Spring device to push waste cup Guide pipe for waste cup Measuring chamber waste cup bin Room for host computer Main switch Power point for instrument Power point for computer USB port Switch for instrument Switch for computer Part 2 Operating Instructions St 1: Step 1 Starting St ti Instrument I t t Wizard Wi d Power off within 48 hours/over 48 hours Power off within 48 hours Screenshot (hereinafter referred to as “S”) 1 1-1-1: 1 1: Open the software of QQ QQ120, pop up the window “Login” S1 1 2: Select “Starting Instrument Wizard” S1-1-2: S1-1-3: S1 1 3: Click “OK” “OK”, pop up the window “Start Wizard” (duration of power off: 24 hours) S1 1 4: Click “next step” S1-1-4: S1 1 5: Fill the bottles with washing solution and select “filled” S1-1-5: S1 1 6: Please wait for pipe washing S1-1-6: S1 1 7: Pipe washing is complete S1-1-7: S1 1 8: Click “next step” to check the performance of reagent probe S1-1-8: S1 1 9: Click “observing now” S1-1-9: S1 1 10: Click “washing now” S1-1-10: S1 1 11: Click “next step” to check the performance of sample probe S1-1-11: S1 1 12: Click “observing now” S1-1-12: S1 1 13: Click “washing now” S1-1-13: S1 1 14: Click “next step” to complete the startup wizard S1-1-14: Power off over 48 hours S1 2 1: Open the software of QQ S1-2-1: QQ-120, 120 pop up the window “Login” S1 2 2: Select “Starting Instrument Wizard” S1-2-2: S1-2-3: S1 2 3: Click “OK” “OK”, pop up the window “Start Wizard” (duration of power of: 72 hours) S1 2 4: Click “next step” S1-2-4: S1 2 5: Fill the bottles with distilled water and select “filled” S1-2-5: S1 2 6: Please wait for pipe washing S1-2-6: S1 2 7: Pipe washing is complete S1-2-7: S1 2 8: Click “next step” S1-2-8: S1 2 9: Fill the bottles with washing solution and select “filled” S1-2-9: S1 2 10: Please wait for lines perfusing S1-2-10: S1 2 11: Lines perfusing is complete S1-2-11: S1 2 12: Click “next step” to check the performance of reagent probe S1-2-12: S1 2 13: Click “observing now” S1-2-13: S1 2 14: Click “washing now” S1-2-14: S1 2 15: Click “next step” to check the performance of sample probe S1-2-15: S1 2 16: Click “observing now” S1-2-16: S1 2 17: Click “washing now” S1-2-17: S1 2 18: Click “next step” to complete the startup wizard S1-2-18: St 2 Step 2: L Loading di Reagent, R t S Samples l &R Reaction ti Cups C Perform T3 & T4 by 10 Samples S2 1: Open the software of QQ S2-1: QQ-120 120 S2-2: S2 2: Select “B” from “Layout Mode” (“A” means reagent preference, preference “B” means sample preference, “C” means unlimited loading) S2 3: Click “Reagent Tray” S2-3: S2 4: Click “System” S2-4: S2 5: Click ”Set Reagent Package” from the pulldown menu S2-5: S2 6: Scan two S2-6: two-dimension dimension barcode of T3 from the kit box Scan barcode label from the top down evenly, never pause in handling S2 7: Scan two S2-7: two-dimension dimension barcode of T4 from the kit box S2 8: Close window ”Management for Reagent” S2-8: S2 9: Activate “T3” from “Reagents List” S2-9: S2 10: Select “A1” from “Location Reagent” S2-10: S2 11: Scan barcode label of T3 Enzyme Conjugate S2-11: Load T3 Enzyme Conjugate in the appropriate well of reagent position S2 12: Activate “T4” from “Reagents List” S2-12: S2 13: Select “A2” from “Location Reagent” S2-13: S2 14: Scan barcode label of T4 Enzyme Conjugate S2-14: Load T4 Enzyme Conjugate in the appropriate well of reagent position S2 15: Select “Sample/Reaction Cup Tray” S2-15: S2 16: Click “Start” S2-16: S2 17: Activate “T3” from “Reagents List” S2-17: S2 18: Double click “C” is used for loading reaction cup of T4 S2-18: S2 19: Activate “T4” from “Reagents List” S2-19: S2 20: Double click “D” is used for loading reaction cup of TSH S2-20: S2 21: Activate “T3” from “Reagents List” S2-21: S2 22: Select “A1” S2-22: S2 23: Scan barcode label of T3 Calibrator S0 S2-23: S2 24: Click “Apply” from window ”Apply Parameter” S2-24: Load T3 Calibrator S0 in the appropriate well of sample position adaptor S2 25: Scan barcode label of T3 Calibrator S1 S2-25: S2 26: Click “Apply” from window ”Apply Parameter” S2-26: S2 27: Click “Reagent” S2-27: S2 28: Select “Apply Standard Automatically” from the pulldown menu S2-28: S2 29: Scan barcode label of T3 Calibrator S2 automatically S2-29: S2 30: Load T3 Calibrator S3 S2-30: S3, S4 S4, S5 in the same way Load T3 Calibrator S1 S1, S2 S2, S3 S3, S4 S4, S5 in the appropriate wells of sample position adaptor after each scanning S2 31: Scan barcode label of T3 Quality Control (L) S2-31: S2 32: Click “Apply” from window ”Apply Parameter” S2-32: S2 33: Click “Reagent” S2-33: S2 34: Select “Apply QC Automatically” from the pulldown menu S2-34: S2 35: Scan barcode label of T3 Quality Control (H) automatically S2-35: Load T3 QC (L) & QC (H) in the appropriate wells of sample position adaptor after each scanning S2 36: Activate “T4” from “Reagents List” S2-36: S2 37: Load T4 Calibrators and Quality Controls in the same way S2-37: Load T4 Calibrators and QCs in the appropriate wells of sample position adaptor after each scanning S2 38: Scan barcode label of Sample 1 S2-38: S2 39: Click “T3” and “T4” or click “Select All” from window ”Apply Parameter” S2-39: S2 40: Click “Apply” from window ”Apply Parameter” S2-40: S2 41: Load Sample 2 S2-41: 2, 3 3, 4 4, 5 5, 6 6, 7 7, 8 8, 9 9, 10 in the same way Load Samples in the appropriate wells of sample position adaptor after each scanning S2-42: S2 42: Click “Status” “Status”, pop up the window “Testing Status” to make sure the right loading S2 43: Close the window “Testing Status” S2-43: S2 44 Activate “T3” from “Reagents List” S2-44 S2 45: Select “C1” S2-45: S2 46: Scan barcode label of T3 Reaction Cup S2-46: S2-47: S2 47: Click “OK” to load 18 pieces (automatic calculating) of T3 Reaction Cup Load 18 pieces of T3 Reaction Cup in row C after scanning S2 48: Scan barcode label of T4 Reaction Cup S2-48: S2-49: S2 49: Click “OK” to load 18 pieces (automatic calculating) of T4 Reaction Cup Load 18 pieces of T4 Reaction Cups in row D after scanning Dispense Substrate A & B from the vials to the appreciate bottles We have loaded all required Enzyme Conjugates Conjugates, Calibrators, Calibrators QCs, QCs Samples and Reaction Cups. S2-50: S2 50: Click “Status” “Status”, pop up the window “Testing Status” to make sure the right loading S2 51: Close the window “Testing Status” S2-51: S2 52: Click “Save” S2-52: “Save”, pop up the window “Save as” S2 53: Name the document S2-53: S2 54: Save the document S2-54: S2 55: Click “Submit” to start test S2-55: St 3 Step 3: Addi Adding Patient P ti t Information I f ti S3 1: Click “Information” during the test procedure S3-1: S3 2: Click “Patient Information” S3-2: Information”, pop up the window “Patient Information” S3 3: Click “Add” S3-3: S3 4: Enter patient details of Sample 1 S3-4: S3 5: Click “Save” S3-5: S3-6 S3 6 Click “Add” and enter patient details of Sample 2 2, 3 3, 4 4, 5 5, 6 6, 7 7, 8 8, 9 9, 10 in the same way S3-7: S3 7: Close the window “Patient Information” Information”, some cups have been sampled and entered into the incubation room. St 4: Step 4 Vi Viewing i Testing T ti Status St t S4-1: S4 1: Click “Status” “Status”, pop up the window “Testing Status” Status”, some cups have been sampled and entered into the incubation room. S4 2: Click “Incubation” S4-2: “Incubation”, some cups are in the incubation room room. S4-3: S4 3: Click “Others” “Others”, cup is sampling in position “S” and shaking in position “R1/R2” S4 4: Click “Layout” S4-4: “Layout”, all cups were moved away from row “C” and row “D” “D”. S4 5: Click “Others” S4-5: “Others”, all cups were sampled and shaked S4 6: Click “Incubation” S4-6: “Incubation”, all cups are in the incubation room S4 7: Click “Others” S4-7: “Others”, the first cup comes out from the incubation room S4 8: Cups will be washed for 5 times by automatic washer S4-8: S4 9: Cups will be sampled with Substrate A & B by automatic dispensor S4-9: S4 10: The first cup is reading in the Measuring Chamber S4-10: S4-11: S4 11: Click “Incubation” “Incubation”, all cups were moved away from the incubation room S4 12: Click “Others” S4-12: “Others”, the last cup is reading in the Measuring Chamber S4 13: All cups have been read. S4-13: read The test procedure is complete St 5: Step 5 Vi Viewing i Testing T ti Report R t S5-1: S5 1: Click “Quantitative” “Quantitative”, pop up the window “Reagent Data Management” of T3 S5-2: S5 2: Click “Print” “Print”, pop up the window “Print standard curve for reagent” of T3, Select “Print” or “Close” according to the need S5-3: S5 3: Close the window “Print standard curve for reagent” reagent”. Click “History”, “History” pop up the window “Calibration Records” of T3 list S5-4: S5 4: Close the window “Calibration Records” of T3 list list. Activate “T4” from left side S5-5: S5 5: Click “Print” “Print”, pop up the window “Print standard curve for reagent” of T4, Select “Print” or “Close” according to the need S5-6: S5 6: Close the window “Print standard curve for reagent” reagent”. Click “History”, “History” pop up the window “Calibration Records” of T4 list S5-7: S5 7: Close the window “Calibration Records” of T4 list and “Reagent Data Management” S5 8: Click “Search” S5-8: “Search”, pop up the window “Case List” S5 9: Enter “%” in “Operation Zone” S5-9: S5 10: Select “Date” S5-10: “Date”, choose the date from 31 Aug 2009 to 31 Aug 2009 S5 11: Click “Search” S5-11: “Search”, get the report list on 31 Aug 2009 S5 12: Click “Print” S5-12: “Print”, get the report of sample 110001 S5 13: Click the pulldown menu of “Preview” S5-13: S5 14: Click “110005” S5-14: “110005”, get the report of sample 110005 S5 15: Click the pulldown menu of “Type” S5-15: S5 16: Click “List” S5-16: “List”, get all reports on 31 Aug 2009 S5 17: Select “Selected” S5-17: S5 18: Click “Print” S5-18: “Print”, get the T3 report of sample 110001 S5 19: Click the pulldown menu of “Type” S5-19: S5 20: Click “List” S5-20: “List”, get the T3 report of sample 110001 S5 21: Activate No S5-21: No. 9 and No No. 10 and Select “Selected” S5 22: Click “Print” S5-22: “Print”, get the T3 & T4 report of sample 110005 St 6: Step 6 Cl Closing i IInstrument t t Wizard Wi d Reuse in 48 hours/after 48 hours Reuse in 48 hours S6 1 1: Close the software of QQ S6-1-1: QQ-120, 120 pop up the window “System Exit” S6 1 2: Select “Closing Instrument Wizard” S6-1-2: S6 1 3: Click “Exit” S6-1-3: “Exit”, pop up the window “Close Wizard” S6 1 4: Select “power off in short time (not more than 48 hours)” S6-1-4: S6 1 5: Click “next step” S6-1-5: S6 1 6: Fill the bottles with distilled water and select “filled” S6-1-6: S6 1 7: Pipe washing is complete S6-1-7: S6-1-8: S6 1 8: Select “active cooler” according to the need and click “completed” to complete the startup wizard Reuse after 48 hours S6 2 1: Close the software of QQ S6-2-1: QQ-120, 120 pop up the window “System Exit” S6 2 2: Select “Closing Instrument Wizard” S6-2-2: S6 2 3: Click “Exit” S6-2-3: “Exit”, pop up the window “Close Wizard” S6 2 4: Select “power off in long time (more than 48 hours)” S6-2-4: S6 2 5: Click “next step” S6-2-5: S6 2 6: Fill the bottles with distilled water and select “filled” S6-2-6: S6 2 7: Pipe washing is complete S6-2-7: S6 2 8: Click “next step” S6-2-8: S6-2-9: S6 2 9: Change the bottles of distilled water with empty bottles, bottles select “have empty” S6 2 10: Pipe evacuating is complete S6-2-10: S6-2-11: S6 2 11: Select “active cooler” according to the need and click “completed” to complete the startup wizard All Rights Reserved This user’s guide is copyrighted, and all rights are reserved. No part of this user’s guide or the products it describes may be reproduced by any means or i any form in f without ith t prior i consentt in i writing iti from f Beijing B iji DoubleQ D bl Q Lab L b Co., C Ltd. This information in this user’s guide was correct at the time of printing. However, DoubleQ Lab continues to improve products and reserves the right to change specifications, equipment, and maintains procedures at any time without notice. QQlab is a registered trademark of Beijing DoubleQ Lab Co., Ltd. Beijing DoubleQ Lab Co., Ltd. www.qqlab.us