Programmer Configuration 2704 Controller 4.11.1. PROGRAM GROUPS Group Edit Page This page is available in operator and configuration level. Table Number: 4.11.1. Parameter Name Group Number These parameters allow you to set up individual Program Groups Parameter Description To select the Group number Load Programs allows a program to be entered and run directly Value Default ‘Load Programs’ or select from 1 to 20 Load Programs L1 0:00:00 L3 Delayed Start To set a time delay before the program will run h:mm:ss Group Status The program group can be controlled from this parameter Reset The status of the program is also shown by text and symbols at the top of this display PSP1 To select the profile to be run in the group. Not Used means PSP1 is not part of the group PROGRAM GROUPS (Group Edit Page) Access Level L1 Run Hold Complete Not Used L1 01:PSP1:P1 to 20:PSP1;P20 01:PSP1:P1 means PSP1 is selected from program 1 to 20 PSP2 As above L1 PSP3 As above Group Name A user configurable name L1 By default if Group Number = Load Programs then Group Name = USER SELECT. USER SELECT GROUP NAME L1 Group 1 to 20 To customise the name press or to change the digit with the flashing cursor. Press to advance the cursor Group Run Group Run Off On R/O L3 R/O Group Hold Group Hold Off On R/O L3 R/O Group Reset Group Reset Off On R/O L3 R/O Group End Group End Off On R/O L3 R/O 4-28 User Guide Part No HA026502 Issue 5.0 Dec-04