Download Machine Controller MP2300S Basic Module USER'S MANUAL
Transcript
2.2 Basic Module 2.2.5 Built-in SVB Module Transmission Distance and Maximum No. of Slave Stations Communication Method MECHATROLINK-I MECHATROLINK-II Transmission Distance (Total Network Length) Maximum Number of Slave Stations 50 m (can be extended to 100 m by connecting repeaters) 14 30 m (can be extended to 100 m by connecting repeaters) 16 (21)* 50 m (can be extended to 100 m by connecting repeaters) 15 (21)* * The values in parentheses apply when a JEPMC-REP2000 Repeater is used. JEPMC-REP2000 Repeater must be used if 17 or more slave stations are connected when using MECHATROLINK-II communication. ( 3 ) Module Configuration [ a ] Module Configuration Window Specifications and Functions Click MP2300S in the Controller area to display the details of the basic module functions in the Module Details area. The cell No.3 provides a detailed definition of built-in SVB. 2 2-37
Related documents
Engineering Tool for MP2000 Series Machine - Support
Machine Controller MP2000 Series 262IF-01 FL
L Excellence Opérationnelle
Machine Controller MP2000 Series 263IF-01
MEMOBUS Ethernet - Pro-face America HMI Store
Scheda controllo assi
Machine Controller MP2200 USER'S MANUAL
YASKAWA Electric Corporation:MP/INVERTER/SERVO Ethernet
User`s Manual
MP2300 Machine Controller Basic Module User's Manual
MP/SERVO Ethernet - Pro-face America HMI Store
Machine Controller MP2200 USER`S MANUAL