Download User's Guide - Equal Parenting
Transcript
Baseline Pattern (optional) This drop-down list defines an optional time pattern whose factors adjust the baseline inflow to vary in a periodic fashion by month of the year, by day of the week, and by time of day (for both weekdays and weekends). If this dropdown list is left blank, then the baseline inflow is not adjusted. Click the [...] browse button to display the Sanitary Time Patterns dialog box to define a new time pattern. Time Series (optional) This column provides a drop-down list item that allows you to select an already defined time series that contains the tabular data of time versus inflow for the selected constituent. If this entry is left blank, then no direct inflow will occur for the selected constituent for the node being defined. Click the [...] browse button to display the Time Series dialog box to define a new direct inflow time series. Scale Factor (optional) This column specifies the multiplier to be used to adjust the values of the pollutant constituent's inflow time series. The baseline value is not adjusted by this factor. The scale factor can have several uses, such as allowing one to easily change the magnitude of an inflow hydrograph while keeping its shape the same without having to re-edit the entries in the hydrograph's time series. Or, it can allow a group of nodes sharing the same time series to have their inflows behave in a time-synchronized fashion while letting their individual magnitudes be different. If left blank, then the scale factor defaults to a value of 1.0. Inflow Type For pollutant constituents, the drop-down list allows you to select the type of inflow data contained in the specified time series data as either concentrations or mass inflows. This field is not available for the FLOW inflow row. Conversion Factor For pollutant constituents, this entry is used to define the numerical conversion factor for converting a pollutant mass flow rate in the time series data into concentration times flow units. This field is not available for the FLOW inflow row. For example, if the time series data is in pounds per day and the pollutant concentration defined for the project is in mg/L while the flow units are CFS, then the conversion factor is (453590 mg/lb) / (86400 sec/day) = 5.25 (mg/sec) per (lb/day). Dry Weather (Sanitary) Inflows The Dry Weather (Sanitary) Inflows section of the Inflows dialog box is used to specify a continuous source of dry weather flow entering the node being defined. Dry weather inflows are continuous inflows that typically reflect the contribution from sanitary sewage in sewer systems or base flows in pipes and stream channels. They are represented by an average inflow rate that can be adjusted on a monthly, daily, and hourly basis by applying time pattern multipliers to this average value. The following data are used to define dry weather inflow: Constituent This read-only column provides a list of FLOW and previously defined pollutant constituents whose dry weather inflow is to be defined. 430 | Chapter 9 Subbasin Element Data
Related documents
Buhler 2425 Operator`s manual
Samoa training report, capacity building in flood risk
STORM WATER MANAGEMENT MODEL USER`S MANUAL Version
Reference Manual
MANUAL DEL USUARIO - Título de Especialista Universitario en
USER`S GUIDE - Belcheff & Associates, Inc.
Avis Technique 2/13-1535 Coussins à membranes ETFE
By: Laurent Wismer & George Oner Water and Habitat Unit
Reference Manual
Chapter 1 - An Overview of MIDUSS 98
User`s Manual (December 2014)