Download INSTALLATION MANUAL

Transcript
Circuit diagram
Chimney draught fan PXSF
CHIMNEY DRAUGHT FAN PXSF
Circuit diagram
Burner
• Attach the cable from the fan to the connector (47 V).
• Attach the 230 VAC mains power supply to (L) and (N).
Stove: pole number 7 on the 7-pole
Burner: one of the cords (1) from the cable kit
• Attach the plug (2) to the feeder motor.
White
• Attach the plug (3) to the burner left side.
• Attach one of the cords (1) from the cable kit (Y1).
Time relay
Y1
Speed
regulator
Tyron1
Transformer
Transformer
Black
2
230 0
47 38 0
VAC
Fan
Black
Black
Blue
Blue
Black
3
4
5
47V
Blue
Make sure the switches on the time relay are
in position 1-10 minutes, maximum
(clockwise) and C, respectively.
This means the fan will start
1
when the pellet feeder
starts, and it stops 10 minutes
after the last pellet feed.
18
A1
16 Time relay 15
A2
Y1
NOTE!
if the fan starts when the burner is in OFF position, switch to the other wire in cable
(1). The fan should start only when the pellet feeder starts.
L
N
ARITERM SWEDEN AB
Installation Instructions - 2007.12.14 - 3/4