Download FX2N-1HC SPECIAL FUNCTION BLOCK USER'S GUIDE
Transcript
3.3 Buffer memories (BFM) 2. WIRING BFM number PNP output encoders PNP output encoders FX2N-1HC SPECIAL FUNCTION BLOCK 3.3k A24+ 1.5k A12+ 0.27k A5 + 0.1k Shielding Wire Phase A OUT ØA USER’S GUIDE Phase B A B24+ B12+ B5 + B - Shielding Wire OUT JY992D65401D ØB Shielding Wire Phase Z This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-1HC special function block and should be read and understood before attempting to install or use the unit. Further information can be found in the FX PROGRAMMING MANUAL and FX2N SERIES HARDWARE MANUAL. PRESET +24V COMP DISABLE Shielding Wire COM XD24 XD 5 :source :sink YH+ 2.2kW YH- *1 *1 YS+ 2.2kW 12 to 24V inputtaable YS- *1 *1 Write / Read COMD START *1. " " is an external load connected with the out put. *2. Connect the grounded terminal at the PLC side as required. +24V 1. INTRODUCTION The hardware high-speed counter block is a 2-phase 50 kHz high-speed counter. It is a special function block for the FX2N, FX2NC, FX3U series PLC. • FROM/TO instruction transfers the PLC data (i.e. parameters, comparing value and present value). • The FX2N-1HC occupies 8 points of I/O on the FX2N, FX2NC expansion bus. The 8 points can be allocated from either inputs or outputs. • Differential-Line-Driver (AM26C31 or equivalent) and open collector output encoders are available for FX2N-1HC. • The source of your input signal should be a 1 or 2 phase encoder. A 5V, 12V, or 24V power source can be used. An initial value setting command input (PRESET) and a count prohibit command input (DISABLE) are also available. • • 0V Class 3 grounding (<100: ) External power source DC5V,12V,24V Line driver output encoders Shielding Wire LA LAR B5+ B- 3.1 General specifications Mass (weight): Approx. 0.3 kg (0.66 lbs) Dimensions: mm (inches) Accessories: Self-adhesive labels special block number identification. POWER 7 80(3.15) Specification Same as those for the FX2N main unit 500V AC, 1min (between all terminals and ground) 1-phase input 1 input 2 inputs Mounting hole 2-φ4.5 (0.18) Extension cable and connector UP LED DN (Down) LED φA LED φB LED POWER LED φA, φB terminal (M3 (0.12) screws) PRESET terminal (M3 (0.12) screws) 10 11 12 13 14 15 16 17 9 Input signal MAX. frequency 50 kHz t1 t1 t2 Pulse shape 10 YHxYS terminal (M3 (0.12) screws) DISABLE terminal (M3 (0.12) screws) DIS (DISABLE) LED PRESET LED YH LED YS LED DIN rail clip Attachment groove for 35 (1.38) wide DIN rail FOR M3 (0.12 inches) 6.2mm (0.24 inches) or less • Use crimp terminals of the dimensions specified in the left figure. • Secure the terminals using a tightening torque of 0.5 to 0.8 Nxm (5 to 8 kgxcm). • Wire only to the module terminals discussed in this manual. Leave all others vacant. 2 edge count Default: K32,767 #15,#14 YS compare value Upper/Lower Default: K32,767 #21,#20 Counter current value Upper/Lower Default: K0 #23,#22 Maximum count value Upper/Lower Default: K0 #25,#24 Minimum count value Upper/Lower Default: K0 #26 Compare results #27 Terminal status #29 Error status #30 Model identification code K4010 t2 t3 K1 K2 K3 K4 K5 1-phase 2-input (add/subtract pulse) K6 K7 Hardware UP/DOWN K8 K9 Software UP/DOWN K10 K11 c) t1 :Rise/fall time is 3µs or less t2 :ON/OFF pulse 6µs or more (at 50kHz) t3 :Phase difference between A and B is 3.5µs or more (at 50kHz) PRESET(Z phase) input 100µs or more DISABLE (count prohibit) input 100µs or more When 32-bit is specified : -2,147,483,648 to +2,147,483,647 When 16-bit is specified : 0 to 65,535 (upper limit can be user specified) Comparison Type Each output is set when the present value of the counter matches with the compare value (which is transferred from the PLC), and is switched OFF by a reset command from the PLC. YH : Direct output processed by hardware. YS : Software processed output with worst delay time of 300µs. (Therefore, when the input frequency is 50 kHz, there is a worst case delay of 15 input pulses.) Output capacity YH + : transistor output for YH output YH − : transistor output for YH output YS + : transistor output for YS output YS − : transistor output for YS output YH+ YS+ NPN 16-bit counter modes A 16-bit binary counter handles only positive values from 0 to 65,535. Changes to zero from the upper limit value or to the upper limit value from zero when overflow occurs; the upper limit value is determined by BFMs #3 and #2. +2,147,483,647 Upper limit value 0 Lower limit value -2,147,483,648 0 Ring length (BFM#3,#2) 1-phase 1-input counter (K8 to K11) Phase A YHYS- Phase B OFF UP Current value d) DOWN 8 points taken from the FX2N expansion bus (can be either inputs or outputs) Power from base 5V DC 90mA(Internal power supply from main unit or powered extension unit) K1 ON UP/DOWN is determined by input phase A (ON/OFF). Phase B Current value OFF UP DOWN UP/DOWN is determined by the contents of BFM #1, (K0/K1). 1-phase 2-input counter (K6, K7) ON OFF Phase A input Phase A input-1 at OFFo ON Phase ON B input OFF 1 2 3 3 3 2 1 0 e) K0 BFM#1 Phase B input+1 at OFFo ON If both phase A and phase B inputs are received simultaneously, the counter value does not change. 2-phase counter (K0 to K5) • 2 edge-count (K2, K3) • 1 edge-count (K0, K1) Phase A Phase A +1 +1 -1 Phase B -1 +1 +1 -1 Phase B input OFF o ON while phase A input ON Count up by 1. Phase B input ON o OFF while phase A input ON Count down by 1. Phase B input OFF o ON while phase A input ON Count up by 1. Phase B input ON o OFF while phase A input ON Count down by 1. • 4 edge-count (K4, K5) DOWN COUNT UP COUNT Phase A input Phase B input -1 Phase B 5V to 24V DC 0.5A I/O occupation • Software UP/DOWN (K10, K11) ON OFF ON 12.5kHz Range Types of outputs The counter mode is selected form the PLC. As shown below, values between K0 and K11 are written to buffer memory BFM #0 form the PLC. When a value is written to BFM #0 the contents of BFM #1 to BFM #31 are reset to default values. When setting this value use a TOP (pulsed) instruction use M8002 (initial pulse) to drive the TO instruction. A continuous command is not allowed. 32-bit counter modes A 32-bit binary counter which executes UP/DOWN counting will change from the lower limit value to the upper limit value or the upper limit value to the lower limit value when overflow occurs. Both the upper and lower limit values are fixed values: the upper limit value is +2,147,483,647, and the lower limit value is -2,147,483,648. • Hardware UP/DOWN (K8, K9) 7mA or less 7mA or less 12.5mA or less 15mA or less 8mA or less Automatic UP/DOWN (however, when on 1-phase 1-input mode, UP/DOWN is determined by a PLC command or an input terminal.) Counting specification Output signal 25 kHz 32 bits 16 bits 4 edge count Format <Using the solderless termination> 6.2mm (0.24 inches) or less 1 edge count [A24+],[B24+] :24V DC±10% [A12+],[B12+] :12V DC±10% [A5+],[B5+] :3.0V to 5.5V DC PRESET, DISABLE [XP24],[XD24] :10.8V to 26.4V DC [XP5],[XD5] :5V DC±10% (Selected by terminal connection) t3 1 2 3 4 5 6 7 8 9 2-phase input Phase A, Phase B Signal level 4(0.16) Default: K0 YH compare value Upper/Lower K0 b) General specifications (excluding the following) 11 FX2N-1HC XP5 YH+ YS+ YH YS 16 COMP YH- YS- DIS PRE 11 12 13 14 15 Preset data Upper/Lower #13,#12 1 edge count 2-phase input 2 edge count (phase difference pulse) 4 edge count a) Dielectric withstand voltage Item B5+ XD24 XP24 B - XD5 COMD 90(3.54) øA øB #11,#10 1) BFM #0 Counter mode (K0 to K11), BFM #1 DOWN/UP command 3.2 Performance specifications A24+ A5+ B24+ DOWN 3 4 5 6 A12+ A - B12+ 17 A24+ A5+ B24+ A12+ A - B12+ 1 UP Connect other terminals as shown in the PNP output encoder figure above. Item 8 Default: K0 #5-#9, #16-#19, #28, #31 are reserved. Perform the dielectric withstand voltage test between the GND terminal and all the other terminals short-circuited. 55(2.17) Default: K65,536 Command 1-phase 1-input 1.1 External dimensions 4(0.16) When applying the Differential-Line-Driver encoder (AM26C31 or equivalent) to FX2N-1HC, connect the encoder output with the 5V DC terminal as shown in the left figure. A5+ A- LB LBR Default: K0 Count modes FX2N-1HC Various counter modes, such as 1-phase or 2-phase, 16-bit or 32-bit modes, can be selected using commands from the PLC. Allow the FX2N-1HC unit to run only after setting these mode parameters. 2 Power supply for out put load drive DC5 to 24V Default: K0 DOWN/UP command (1-phase 1-input mode) Ring length Upper/Lower Read Differential-Line-Driver output encoders 3. SPECIFICATIONS 55(2.17) PLC If using on NPN output encoder please take care to match the polarity of the terminals of the encoder to those of the FX2N-1HC. The FX2N-1HC has two outputs. When the counter value coincides with an output compare value, the appropriate output is set ON. The output transistors are individually isolated to allow either sink or source connection methods. 87(3.43) +24V 0V Extension cable *2 Counter mode K0 to K11 #1 #4 1.5k 0.2k #0 #3,#2 Write 12 to 24V inputtable XP24 0.5k XP 5 OUT FX2N-1HC Contents Phase A input +1 +1 +1 +1 Phase B input -1 -1 -1 -1