Download Programmable DC Power Supply User's Manual
Transcript
7.6 State Bit Definition When “ STATE?” command is used, the system will return three (3) bytes in the order as shown below. Byte 2 Byte 1 Byte 0 bit 7 ~ bit 0 bit 7 ~ bit 0 bit 7 ~ bit 0 The definition of each bit is described in the following table. byte 0: bit 7 OVP on/off status bit 6 OCP on/off status bit 5 OPP on/off status bit 4 CC to CV on/off status bit 3 CV to CC on/off status bit 2 output on/off status bit 1 LCD back light on/off status bit 0 External 5V output on/off status byte 1: bit 7 OVP occur flag bit 6 OCP occur flag bit 5 OPP occur flag bit 4 CC to CV occur flag bit 3 CV to CC occur flag bit 2 AC dectect low occur flag bit 1 OTP occur flag bit 0 reserved byte 2: bit 7 ~ 0 reserved 7.7 LAN Communction All DS series provide three LAN control modes, including Web server, Telnet and Sockets. First, enter the first Item “ System Setting” on the menu to set the interface selection (Remote Control) as Ethernet, and select IP setting procedure as Static or use DHCP (Dynamic Host Configuration Protocol). If using static IP, it needs to set up IP address. After completed, it will be able to use the above LAN control mode to control the DS series. 75