Download Operating instructions

Transcript
Product description
2.1
Technical data
Technical data S 101-3...S 150-3 / SD 101-3...SD 150-3, part 2
S 101-3
SD 101-3
S 125-3
SD 125-3
S 150-3
SD 150-3
[l]
[l]
120
65
120
65
120
65
[l]
10
10
10
+5
+ 40
+5
+ 40
+5
+ 40
Type
Oil filling quantity
Oil receiver volume
Total oil filling quantity
Oil topping up quantity
between min. + max.
Intake air temperature
– min.
– max.
[m3/h]
[m3/h]
[Pa]
[mm WS]
20000
10000
60
6
32000
16000
60
6
32000
16000
60
6
Cooling air requirement
– free-standing installation
– with supply and exhaust duct
[m3/h]
[m3/h]
3400
1700
3400
1700
3400
1700
Required cooling water quantity
– delta t = 15 K
– delta t = 30 K
Max. cooling water quantity
[m3/h]
[m3/h]
[m3/h]
4,090
2,045
9,0
4,900
2,450
9,0
6,000
3,000
9,0
Cooling water inlet temperature
– min.
– max.
[°C]
[°C]
+5
+ 30
+5
+ 30
+5
+ 30
Cooling water outlet temperature
– max.
[°C]
+ 45
+ 45
+ 45
Cooling water pressure
– min.
– max.
[bar]
[bar]
2
10
2
10
2
10
– pmax = 8 bar: Switch-off press. pmax
Switch-on press. pmin
[bar]
[bar]
8
7
8
7
8
7
– pmax = 10 bar: Switch-off press. pmax
Switch-on press. pmin
[bar]
[bar]
10
9
10
9
10
9
– pmax = 13 bar: Switch-off press. pmax
Switch-on press. pmin
[bar]
[bar]
13
12
13
12
13
12
Safety valve
Activation pressure at:
– pmax = 8 bar
– pmax = 10 bar
– pmax = 13 bar
[bar]
[bar]
[bar]
11
11
14
11
11
14
11
11
14
Water cooling
Air cooling
Cooling air requirement
– free-standing installation
– with supply and exhaust duct
– free fan compression
– free fan pressure
Operating pressure sensor 1
(factory settings)
1)
[°C]
[°C]
)
Compressors for other operating pressures pmin = pmax –1 bar.
Page 16
Operating instructions for S 31-3...S 150-3 series screw compressors