Download Operating instructions

Transcript
Product description
2.1
Part 2: Product description
Technical data
2.1 Technical data
Technical data SLF 30-3...SLF 125-3, part 1
SLF 30-3 /
SLDF 30-3
SLF 40-3 /
SLDF 40-3
1442 / 1729
1442 / 1729
–
–
1880 / 1973
985
1880 / 1973
985
775 / 899
845 / 1055
–
Max. sound pressure level
[±3 dB(A)]
accord. to DIN EN ISO 2151:2009
– silenced / super silenced
[dB(A)]
Measurement surface
– silenced / super silenced
Sound power level
– silenced / super silenced
Type
SLF 51-3
SLF 61-3
SLF 75-3
SLF 101-3
SLF 125-3
1453
1949
2043
1065
1453
1949
2043
1065
1453
1949
2043
1065
1759
2255
2414
1315
1759
2255
2414
1315
–
1250
1300
1380
1430
1498
1548
2112
2172
2162
2222
67 / –
70/ –
79 / 73
80 / 74
81 / 75
76 / 72
79 / 74
[dB(A)]
15 / –
15 / –
16 / 17
16 / 17
16 / 17
17 / 18
17 / 18
[dB(A)]
82 / –
85 / –
95 / 90
96 / 91
97 / 92
93 / 90
96 / 92
Max. sound pressure level
[±3 dB(A)]
accord. to DIN EN ISO 2151:2009
– silenced / super silenced
[dB(A)]
66 / –
69 / –
78 / 72
79 / 73
80 / 74
72 / 70
72 / 70
Measurement surface
– silenced / super silenced
[dB(A)]
15 / –
15 / –
16 / 17
16 / 17
16 / 17
17 / 18
17 / 18
Sound power level
– silenced / super silenced
[dB(A)]
81 / –
84 / –
94 / 89
95 / 90
96 / 91
89 / 88
89 / 88
110
110
110
110
110
110
110
1,20 – 3,87
–
1,30 – 5,31
1,30 – 4,75
1,26 – 4,21
2,30 – 7,16
2,25 – 6,43
2,12 – 5,18
2,40 – 7,90
2,30 – 7,00
2,14 – 5,78
2,20 – 9,60
2,10 – 8,50
2,18 –7,26
5,10 – 13,96
4,94 – 12,25
3,68 – 10,69
4,98 – 15,70
4,93 – 14,93
4,79 – 12,80
[kW]
22
30
37
45
55
75
90
[min-1]
3000
3000
1500
3000 (1500)
3000 (1500)
3000 (1500)
3000
IP
IMB
55
35
F
55
35
F
55
35
F
55
35
F
55
35
F
55
35
F
55
35
F
[V]
[Hz]
[A]
400
50
63
400
50
80
400
50
100
400
50
125
400
50
160
400
50
200
400
50
250
Dimensions
– Height (silenced)
– Height (super silenced)
– Width
– Depth
Water cooling
Air cooling
Weight
– silenced
– super silenced
Compressor
Max.final compression temperature
Volume flow according to
ISO 1217, Annex C at:
– pmax = 8 bar
– pmax = 10 bar
– pmax = 13 bar
Drive motor
Rated power
Rated speed
– 50 Hz
Protection type
Design
ISO-class
Electrical connection
Mains voltage 1) 2)
Frequency 1)
Recommended fuse protection 3) 4)
1)
2)
3)
4)
[mm]
[mm]
[mm]
[mm]
[kg]
[kg]
[°C]
[m3/min]
[m3/min]
[m3/min]
–
Standard equipment. Mains voltages and frequencies are specified on a plate in the switch cabinet.
The refrigerant air dryer requires 230 V / 50 Hz.
Only for 400 V / 50 Hz. The fuse values change in the case of other mains voltages and frequencies.
Use fusible cutouts gL – gG or circuit-breakers with C-characteristic only.
BOGE operating instructions for screw compressors Series SLF 30-3...SLF 125-3
Page 13