Download Operating instructions
Transcript
Product description 2.1 Part 2: Product description Technical data 2.1 Technical data Technical data SLF 30-3...SLF 125-3, part 1 SLF 30-3 / SLDF 30-3 SLF 40-3 / SLDF 40-3 1442 / 1729 1442 / 1729 – – 1880 / 1973 985 1880 / 1973 985 775 / 899 845 / 1055 – Max. sound pressure level [±3 dB(A)] accord. to DIN EN ISO 2151:2009 – silenced / super silenced [dB(A)] Measurement surface – silenced / super silenced Sound power level – silenced / super silenced Type SLF 51-3 SLF 61-3 SLF 75-3 SLF 101-3 SLF 125-3 1453 1949 2043 1065 1453 1949 2043 1065 1453 1949 2043 1065 1759 2255 2414 1315 1759 2255 2414 1315 – 1250 1300 1380 1430 1498 1548 2112 2172 2162 2222 67 / – 70/ – 79 / 73 80 / 74 81 / 75 76 / 72 79 / 74 [dB(A)] 15 / – 15 / – 16 / 17 16 / 17 16 / 17 17 / 18 17 / 18 [dB(A)] 82 / – 85 / – 95 / 90 96 / 91 97 / 92 93 / 90 96 / 92 Max. sound pressure level [±3 dB(A)] accord. to DIN EN ISO 2151:2009 – silenced / super silenced [dB(A)] 66 / – 69 / – 78 / 72 79 / 73 80 / 74 72 / 70 72 / 70 Measurement surface – silenced / super silenced [dB(A)] 15 / – 15 / – 16 / 17 16 / 17 16 / 17 17 / 18 17 / 18 Sound power level – silenced / super silenced [dB(A)] 81 / – 84 / – 94 / 89 95 / 90 96 / 91 89 / 88 89 / 88 110 110 110 110 110 110 110 1,20 – 3,87 – 1,30 – 5,31 1,30 – 4,75 1,26 – 4,21 2,30 – 7,16 2,25 – 6,43 2,12 – 5,18 2,40 – 7,90 2,30 – 7,00 2,14 – 5,78 2,20 – 9,60 2,10 – 8,50 2,18 –7,26 5,10 – 13,96 4,94 – 12,25 3,68 – 10,69 4,98 – 15,70 4,93 – 14,93 4,79 – 12,80 [kW] 22 30 37 45 55 75 90 [min-1] 3000 3000 1500 3000 (1500) 3000 (1500) 3000 (1500) 3000 IP IMB 55 35 F 55 35 F 55 35 F 55 35 F 55 35 F 55 35 F 55 35 F [V] [Hz] [A] 400 50 63 400 50 80 400 50 100 400 50 125 400 50 160 400 50 200 400 50 250 Dimensions – Height (silenced) – Height (super silenced) – Width – Depth Water cooling Air cooling Weight – silenced – super silenced Compressor Max.final compression temperature Volume flow according to ISO 1217, Annex C at: – pmax = 8 bar – pmax = 10 bar – pmax = 13 bar Drive motor Rated power Rated speed – 50 Hz Protection type Design ISO-class Electrical connection Mains voltage 1) 2) Frequency 1) Recommended fuse protection 3) 4) 1) 2) 3) 4) [mm] [mm] [mm] [mm] [kg] [kg] [°C] [m3/min] [m3/min] [m3/min] – Standard equipment. Mains voltages and frequencies are specified on a plate in the switch cabinet. The refrigerant air dryer requires 230 V / 50 Hz. Only for 400 V / 50 Hz. The fuse values change in the case of other mains voltages and frequencies. Use fusible cutouts gL – gG or circuit-breakers with C-characteristic only. BOGE operating instructions for screw compressors Series SLF 30-3...SLF 125-3 Page 13