Download Solution 8 Installation Manual
Transcript
Solution-8 Installation Manual Page 25 User Codes 0...0 Locations 68 - 163 These are the 14 user codes available that can be altered at will by the master code holder. If Openings and Closing's (locations 200 and 201) are programmed, then any code being used to arm and disarm the system, will be transmitted to the monitoring station as the appropriate user number. User Number User 2 User 3 User 4 User 5 User 6 User 7 User 8 User 9 User 10 User 11 User 12 User 13 User 14 User 15 Location 68 to 73 74 to 79 80 to 85 86 to 91 92 to 97 98 to 103 104 to 109 110 to 115 116 to 121 122 to 127 128 to 133 134 to 139 140 to 145 146 to 151 Any user code starting with '00' will only arm the system. This can be helpful when you need to give a code to someone who is only allowed to arm but not disarm the system such as a cleaner or guest. NOTE: If 6 digit codes are required a '1' must be programmed into location 214. Auxiliary Codes There are two auxiliary codes which are capable of triggering any two of the four programmable outputs. As an example these codes could be used to unlock a door to allow access into a secured area. Outputs can only be triggered from these codes while the system is in the disarmed state. An appropriate output will have to be programmed so that this function can operate. These codes can be changed from the operators programming mode (Master code + 1) as they are treated as user codes 16 and 17 respectively. These codes do not arm or disarm the system. Their only function is to operate the programmable outputs. Auxiliary Code Aux code 1 Aux code 2 Location 152 to 157 158 to 163 Electronics Design & Manufacturing ISSUE401.DOC