ELECTROLYTIC CHLORINE GENERATOR
BASIC POOL MAINTENANCE REQUIREMENTS
WEEKLY
IDEAL RANGE
Free Chlorine
1.0 - 3.0 ppm
pH
7.2 - 7.6
MONTHLY
TEST
Alkalinity
ADJUSTMENT REQUIRED
Raise desired output % to
increase, lower desired output %
to decrease -OR- increase or
decrease pump filtration time.
Too high - add muriatic acid
Too low - add soda ash.
QUARTERLY
Salt
80 - 120 ppm
Shown with optional AQL-CHEM Chemistry Kit
2700 - 3400 ppm Add salt as required to increase.
Stabilizer
60 - 80 ppm
Add cyanuric acid to increase.
Calcium
200 - 400 ppm
Add calcium to increase.
Drain and add water to decrease.
Electrolytic Cell inspect & clean
G
Add baking soda to increase.
Add acid as required to decrease.
Electronic Chlorine Generator
Refer to section in manual.
Questions?
Operation and Installation
Manual
Refer to www.goldlinecontrols.com for latest manual
revisions, additional information and helpful service.
AQ-RT-PRO
LDLINE
G
C ON TROLS
N. Kingstown, RI 02852 USA
092392A
Copyright © 2008 Goldine Controls
LDLINE
C ON TROLS
www.goldlinecontrols.com