P R O G R A M D E S C R I P T I O N S once AC power has been restored for the amount of time programmed for AC Failure. Communication delays. NOTES: If AC Failure Communications Delay is programmed as 000, the AC Failure Trouble reporting code will be sent immediately. For proper communication of PC5204 AC troubles, program the AC Failure Communictaion Delay as “000”. A Bell Circuit Trouble Alarm Reporting Code will be transmitted immediately if an open condition is measured on the Bell Output of the main panel. The Bell Circuit Trouble Restoral Reporting Code will be transmitted as soon as the problem is corrected. A Fire Trouble Alarm Reporting Code will be transmitted immediately when an open condition is measured on any Fire type zone (See Section 5.1 “Zone Definitions”). The Fire Trouble Restoral Reporting Code will be transmitted as soon as the problem is corrected. The Auxiliary Power Supply Trouble Alarm Reporting Code will be transmitted if the AUX output is shorted. The AUX output control incorporates a fuseless design. When excessive current is drawn the panel will automatically shut off the output. The panel will constantly check the AUX output and when the excessive current draw is removed the panel will reset the output and transmit an Auxiliary Power Supply Trouble Restoral Reporting Code. A TLM Trouble Reporting Code can only be transmitted if an Alternate Communicator is being used (See Section 5.26 “LINKS1000 Cellular Communicator”). The panel will only transmit the signal after the time programmed for the TLM Trouble Delay. The TLM Restoral Reporting Code will be transmitted immediately once the trouble is restored. A General System Trouble Reporting Code will be transmitted if the panel detects any of the following on the PC5204 Power Supply/Output Module: AC Power Failure, Low Battery, AUX Output Trouble, Output #1 Supervisory trouble. The General System Trouble Restoral Reporting Code will be transmitted when all of the listed problems are corrected. A General System Supervisory Trouble Reporting Code will be transmitted if any module goes missing from the Keybus. If the module is a zone expander the panel will also transmit the Zone Expander Supervisory Alarm Trouble Reporting Code. The panel will send a General System Supervisory Restoral Reporting Code when the problem is corrected as well as a Zone Expander Supervisory Restoral Reporting Code if the module is a zone expander. 5.7.6 Zone Restorals If the Restoral on Bell Time-out option is selected, the panel will send the Zone Restoral Reporting Code for the zone if the bell cut-off time has expired and the zone is secured. If the zone is not secured when the bell cut-off time expires, the panel will send the restoral immediately once the zone is secured, or when the system is disarmed. If the Restoral on Bell Time-out option is not selected, the panel will immediately send the Zone Restoral Reporting Code when the zone is secured, regardless of whether or not the alarm output is active. 24 Hour type zones will report the restoral immediately when the zone is secured. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Restoral on Bell Time-out ....................................... Section [380], Option [2] AC Failure Communication Delay Time ................. Section [370] ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 5.8 Downloading Downloading allows programming of the entire control panel via a computer, modem and telephone line. All functions and features, changes and status, such as trouble conditions and open zones can be viewed or programmed by downloading. When power is applied to the panel, a 6 hour downloading window can be enabled. This will allow you to perform downloading without having to do any keypad programming. If the Answering Machine / Double Call option is enabled (or during the first 6 hours after power up) the panel will answer incoming calls for downloading provided the following conditions occur: 1. The panel hears one or two rings then misses a ring. 2. At this point the panel will start a timer. 3. If the panel hears another ring before the Answering Machine Double Call Timer expires it will answer on the first ring of the second call. The panel will immediately go on line and begin the download process unless the Call Back option is enabled. If enabled, the panel and computer will both hang up. The panel will then call the Download Computer Telephone Number and wait for the computer to answer. Once the computer answers downloading will begin. If the User Enabled DLS Window option is ON, the user can activate the downloading feature for a set period of time by entering [✱] [6] [Master Code] [5]. If the Full 6-hour User Enabled DLS Window option is enabled, when the user opens the DLS window with [✱][6][Master code][5], the DLS window will remain open for six hours. The DLS window will remain open after a successful hang-up from a downloading call. If the One Time 1-hour User Enabled DLS Window option is enabled, when the user opens the DLS window with [✱][6][Master code][5], the DLS window will stay open for one hour, and will close after a successful hang-up from a downloading call. 29