Download Solution 862 Installation Manual

Transcript
Dialler Reporting Formats
125
?&*#$!"6!C&',.!
The table below shows the different Point ID Codes and Event Codes that are transmitted to
the base station receiver when using Contact ID Reporting Format. All event codes are fixed
and will always transmit the same code as there are no programming locations made available
to alter these.
B"&'%(,A(
@$C549(
Zones
1-8
OF4'%(
A4-69&2%&"'(
OF4'%(
<"74(
(
O\2#.'.%&"'(
(
B.34(
Burglary Zone
130
Burglary
162
Medical Zone
100
24 Hour Medical
163
Panic Zone
120
24 Hour Panic
163
Hold-Up Zone
122
24 Hour Hold-Up
163
Tamper Zone
137
24 Hour Tamper
163
Burglary Zone
133
24 Hour Burglary
164
Fire
110
24 Hour Fire
164
Open/Close Report
401
Opening – User #
Closing – User #
151
030
AC Mains Fail
301
AC Power
183
031
Low Battery
309
Battery Test Failure
184
040
Codepad Duress
121
Duress Alarm
180
041
Codepad Panic
120
Panic Alarm
180
046
Codepad Fire
110
Fire Alarm
181
045
Codepad Medical
100
Medical Alarm
181
042
Code Retry Limit Exceeded
421
Access Denied
185
044
Test Report
602
Test Report
187
Sensor Watch
307
Sensor Self Test Failure
178
Trouble
380
Sensor Trouble
177
Bypass
570
Zone Bypass
176
Fuse Fail
300
System Trouble
182
User Codes
1 - 16
Zone Specific
1–8
Zone Specific
1-8
Zone Specific
1–8
00
Table 47: Point ID Codes