Download Solution 862 Installation Manual
Transcript
Zone Information 171 <&#,!E:$*&#.!T! When programming this location, you will notice that there are four options per location. You may select one, two, three or all four of these options, however, only one number needs to be programmed. This number is calculated by adding the option bit numbers together. Program a seven (7) if you require options 1, 2 and 4 simultaneously (i.e. 1 + 2 + 4 = 7). ;2%&"'( A4-69&2%&"'( 1 Isolate In STAY Mode 1 2 Zone Isolation Allowed 4 Forced Arming Allowed 8 Zone Restore Report Table 76: Zone Options 2 ,-"#.%4(,'(!0MQ(/"74(G( G( If this option has been selected, it will allow the zone to be automatically isolated when the system has been armed in STAY Mode 1. If this option is not selected, when the system has been armed in STAY Mode 1, the zone will activate an alarm when triggered as it normally would in AWAY Mode. Refer to Entry Guard Timer For STAY Mode on page 205 if you wish to program a global entry time for ALL zones except for 24 hour zone types when armed in STAY Mode 1 (i.e. The entry guard timer will override the delay time programmed for a delay zone). If the entry guard timer has been programmed as "0" each zone will act as per its programmed zone type. Refer to Arming The System In STAY Mode 1 on page 54 for more information. ?"'4(,-"#.%&"'(M##"=47( +( If this option has been selected, it will allow the system operator to isolate the zone before arming the system. If this option is not selected, the zone can not be manually isolated. When a zone has been manually isolated, a zone bypass report (Contact ID Event Code 570) will be sent. Refer to Isolating Zones on page 60 for more information. When isolating 24 hour zone types, the 24 hour zone will automatically send a zone bypass report at the time the zone is selected to be isolated. All non 24 hour zone types will only send a bypass report at the time the system is armed. If you require the system not to report zone bypass reports, program “LOCATION 325 - 326” on page 176 as zeros. D"9647(M9C&'3(M##"=47( J( If this option has been selected, it will allow the system to be armed with the zone unsealed. If this option is not selected, the system will not allow the user code holder to arm the system until the zone in question has been sealed or manually isolated. Refer to Isolating Zones on page 60 for more information. ?"'4(E4-%"94(E42"9%( )( If this option bit has been selected, the zone will send restore reports as soon as the zone has restored. If this option bit has not been selected, the zone will not send restore reports after the zone has restored. If a non 24 hour zone has not restored at the time the system is disarmed, the system will automatically send a zone restore report for that zone. All 24 hour zone types will only send a zone restore report at the time the zone has restored. Electronics Design and Manufacturing Pty Limited ISSUE130