Download 3 - SEW-Eurodrive
Transcript
Gearmotors \ Industrial Gear Units \ Drive Electronics \ Drive Automation \ Services Stationary Energy Supply MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Edition 07/2006 11445815 / EN GC430000 Operating Instructions SEW-EURODRIVE – Driving the world Contents 1 Important Notes................................................................................................. 4 2 Safety Notes ...................................................................................................... 6 3 Installation ......................................................................................................... 7 3.1 Unit designation, nameplates and scope of delivery................................. 7 3.2 Support for profile section (TIS10A...-H..-0)............................................ 15 3.3 Profile section (TIS10A...-P..-0/F..-0) ...................................................... 16 3.4 Cable bushings for line cables (TIS10A...-A..-0) ..................................... 18 3.5 TCS10A... compensation box ................................................................. 19 3.6 TVS10A connection distributor................................................................ 20 3.7 Retaining plate TIS10A...-X..-0 ............................................................... 21 3.8 TLS10E line cables and supply cable ..................................................... 22 3.9 Required tools ......................................................................................... 23 3.10 Prefabricating TLS10E line cables .......................................................... 24 3.11 Connecting the TLS line cable to TCS10A / TVS10A ............................. 26 3.12 Prefabricating the TLS10E006-06-1 supply cable................................... 27 3.13 Connecting the TLS10E006-06-1 supply cable to TVS10A .................... 28 4 Technical Data ................................................................................................. 29 4.1 Medium-frequency cable, cable lugs and cable glands .......................... 29 4.2 Electrical properties and approvals of medium-frequency cables........... 29 4.3 UL approvals ........................................................................................... 30 4.4 Dimension drawing TCS10A / TVS10A................................................... 30 4.5 Dimension drawings of supports for profile sections TIS10A...-H..-0...... 32 4.6 Dimension drawings profile sections in fixed design TIS10A...-P..-0 ...... 33 4.7 Dimension drawings of profile sections in flexible design TIS10A...-F..-033 4.8 Dimension drawings of cable bushings TIS10A...-A..-0 .......................... 34 4.9 Dimension drawings of retaining plates TIS10A...-X..-0.......................... 35 4.10 Dimension drawing of shielding plate...................................................... 36 5 Index of Changes ............................................................................................ 37 5.1 Changes to the previous version............................................................. 37 6 Index ................................................................................................................. 38 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 3 Important Notes 1 1 Important Notes Explanation of symbols of safety and warning instructions Operating Instructions Always follow the safety and warning instructions in this publication. Hazard Possible consequences: Severe or fatal injuries. Hazardous situation Possible consequences: Slight or minor injuries. Harmful situation Possible consequences: Damage to the drive and the environment. Tips and useful information. A requirement of fault-free operation and fulfillment of any rights to claim under limited warranty is that you adhere to the information in the operating instructions. Read the operating instructions before you start operating the unit! The operating instructions contain important information about service and should be kept near the unit. Designated use The MOVITRANS® TLS10E line cables are designed for the operation of contactless energy transfer systems for industrial and commercial plants. MOVITRANS® TLS10E line cables are used to connect the TAS10A transformer module on the output side. MOVITRANS® TLS10E line cables are laid along the transmission line. Observe all information on the technical data and the permitted conditions where the unit is operated. The installation equipment MOVITRANS® TIS10A008... may only be used with pick-ups THM10C or THM20C. In longer transmission lines, the MOVITRANS® TCS10A compensation boxes are connected in series to the MOVITRANS® TLS10E line cables. The TVS10A connection distributors are used as connection points for the line cable in the field. Observe all information on the technical data and the permitted conditions where the unit is operated. Do not start up the unit (take it into operation in the designated fashion) until you have established that the machine complies with the EMC Directive 89/336/EEC and that the conformity of the end product has been determined in accordance with the Machinery Directive 98/37/EEC (with reference to EN 60204). 4 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Important Notes 1 The Professional Association (Berufsgenossenschaft, BG) BG regulation B11 "Electromagnetic fields", must be observed during installation, startup and operation of systems with contactless energy transmission by induction for use in industrial workplaces. Application environment Disposal The following uses are prohibited, unless measures are expressly taken to make them possible: • In areas with explosion-hazard • In areas exposed to harmful oils, acids, gases, vapors, dust, radiation, etc. Please follow the current regulations: Dispose of the following materials in accordance with the regulations in force: • Electronics scrap (circuit boards) • Aluminum • Sheet metal • Copper • Plastic (cable jacket) etc. Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 5 Safety Notes 2 2 Safety Notes Installation and startup • Never install damaged products or take them into operation. Submit a complaint to the shipping company immediately in the event of damage. • Installation, startup and service work is to be performed by trained personnel only. They must comply with the accident prevention guidelines and the regulations in force (e.g. EN 60204, VBG 4, DIN-VDE 0100/0113/0160). • Follow the specific instructions during installation and startup of the other components! • Make sure that preventive measures and protection devices correspond to the applicable regulations (e.g. EN 60204 or EN 50178). Required preventive measures: Ground the unit Operation and service 6 • Take appropriate measures (for example, connect binary input DIØØ /CONTROLLER INHIBIT" on the TPS10A stationary converter to DGND) to ensure that the system does not startup unintentionally when the power is switched on. • Before removing the protective cover, disconnect the TPS10A and TAS10A units from the supply system. Dangerous voltages may still be present for up to 10 minutes after disconnection from the power supply source. • The unit has enclosure IP00 with removed cover and dangerous voltages are present at all subassemblies. The unit must be closed during operation. • When the unit is switched on, dangerous voltages are present at the output terminals as well as any connected cables and terminals. This is also the case when the TPS10A stationary converter is inhibited. • The fact that the operation LED V1 and other display elements are no longer illuminated on the TPS10A stationary converter does not indicate that the TPS10A and TAS10A units have been disconnected from the power supply and do not carry any voltage. • Safety functions within the unit may cause system standstill. Removing the source of the malfunction or performing a reset can result in an automatic restart of the system. If this action is not permissible due to reasons of safety, disconnect the TPS10A and TAS10A units from the power supply before correcting the fault. Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Installation Unit designation, nameplates and scope of delivery 3 Installation 3.1 Unit designation, nameplates and scope of delivery 3 Example of a unit designation for the compensation box T C S 10 A E 06 - 0 9 0 - 1 Version: 1 = Standard 2 = Special design Compensation capacity: 090 = 900 nF 120 = 1200 nF Line cable current: 06 = 60 A / 08 = 85 A Enclosure: E = increased enclosure IP65 Version: A Series and generation: 10 = standard Type of installation: S = stationary Component: C = compensation box Type: T = MOVITRANS® Example of a unit designation for connection distributors T V S 10 A E 08 - 0 0 0 - 1 Version: 1 = Standard 2 = Special design Compensation capacity: not installed Line cable current: 06 = 60 A / 08 = 85 A Enclosure: E = increased enclosure IP65 Version: A Series and generation: 10 = standard Type of installation: S = stationary Component: V = connection distributor Type: T = MOVITRANS® Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 7 Installation Unit designation, nameplates and scope of delivery 3 Example of a unit designation for the line cable T L S 10 E 016 - 01 - 1 Version: 1 = Standard 2 = with cable lug Number of single cores: 01 = single-core 06 = six-core Cable cross section: 006 = 6 mm2 008 = 8 mm2 016 = 16 mm2 025 = 25 mm2 041 = 41 mm2 Line cable design: E = round Series and generation: 10 = standard Type of installation: S = stationary Component: L = high-frequency line cable Type: T = MOVITRANS® Sample nameplates 56769AXX Figure 1: Nameplate for TCS10A-E08-120-1 compensation box 56771AXX Figure 2: Nameplate for TVS10A-E06-000-1 connection distributor 8 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Installation Unit designation, nameplates and scope of delivery 3 Example of a unit designation for installation equipment T I S 10 A 0XX - XXX - 0 Version: 0 = standard Support complete (for profile section): H00 = AFT-Profil 180 H01 = Cinetic-Profil 180 H02 = Dürr-Profil 180 Flexible profile section (cable duct), 2.2 m long: F33 = flexible, installation dimension 33 mm F74 = flexible, installation dimension 74 mm Fixed profile section (cable duct), 3 m long: P33 = fixed, installation dimension 33 mm P74 = fixed, installation dimension 74 mm Cable bushing: A00 = grommet A74 = Cable bushing 8 mm2 Retaining plate (for TCS, TVS and TIS10A008-H02-0): H00 = AFT-Profil 180 X01 = Cinetc-Profil 180 X02 = Dürr 180 XH2 = Universal Cable cross section for line cable: 008 = 8 mm2 Version: A Series and generation: 10 = standard Type of installation: S = stationary Component: I = Installation equipment Type: T = MOVITRANS® Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 9 3 Installation Unit designation, nameplates and scope of delivery Scope of delivery compensation box TCS10A, line cable current 60 A / 85 A Scope of delivery connection distributor TVS10A, line cable current 60 A Scope of delivery connection distributor TVS10A, line cable current 85 A Scope of delivery line cable and TLS10E incoming cable without cable lugs Compensation box Scope of delivery TCS10A -E06-090-1 • • • TCS10A -E08-120-1 TCS10A -E08-120-2 TCS10A with blanking plugs installed 2 M8 combi pan head screws, each with lock washer and plain washer 1 M5 combi pan head screw with lock washer and plain washer for equipotential bonding Connection distributor Scope of delivery TVS10A-E08-000-1 • • • • TVS10A with four M25 blanking plugs and two M32 blanking plugs installed 1 M5 combi pan head screw with lock washer and plain washer for equipotential bonding 8 M6 hex nuts 8 jumpers Connection distributor Scope of delivery TVS10A-E08-000-1 • • TVS10A-E08-000-2 • • TVS10A with blanking plugs installed 1 M5 combi pan head screw with lock washer and plain washer for equipotential bonding 4 hex nuts M8 4 jumpers Specify the required length in meters in your order. Line cable without cable lugs TLS10E006-06-1 TLS10E008-01-1 TLS10E016-01-1 TLS10E025-01-1 TLS10E041-01-1 Scope of delivery line cable and TLS10E incoming cable with cable lug at one cable end 10 The scope of delivery also includes a second cable lug for connection to the M8 terminal stud. Specify the required length in meters in your order. Line cable with cable lug at one cable end TLS10E025-01-2 TLS10E041-01-2 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Installation Unit designation, nameplates and scope of delivery Scope of delivery installation equipment TIS10A008... for installation on aluminum profile rails 3 The installation equipment TIS10A008.. (support, profile sections, retaining plates, cable bushings) are suited for installation on aluminum profile rails (e. g. overhead trolley systems). Installation equipment Pos. Support complete with two rotary supports, matching Cinetic aluminum profile rail 180 Unit designation TIS10A008-H00-0 Support complete with two rotary supports, matching AFT aluminum profile rail 180 [4] Support complete with two rotary supports, matching Dürr aluminum profile rail 180 TIS10A008-H01-0 TIS10A008-H02-0 Fixed profile section, installation dimension 33 mm, 3 m long [6] TIS10A008-P33-0 Fixed profile section, installation dimension 74 mm, 3 m long [5] TIS10A008-P74-0 Fixed profile section, installation dimension 33 mm, 2.2 m long [7] TIS10A008-F33-0 Fixed profile section, installation dimension 74 mm, 2.2 m long [8] TIS10A008-F74-0 Cable bushing grommet [2] TIS10A008-A00-0 [3] TIS10A008-A74-0 Cable entry frame for line cable 8 mm 2 TIS10A-008-X00-0 Retaining plate complete with two socket head screws M6x25, matching AFT aluminum profile rail 180 Retaining plate complete with two socket head screws M6x25, matching Cinetic aluminum profile rail 180 [1] Retaining plate complete with two socket head screws M6x25, matching Dürr aluminum profile rail 180 Aluminum profile rail (not included in scope of delivery) TIS10A-008-X01-0 TIS10A-008-X02-0 [9] - • The installation equipment TIS10A008... may only be used with pick-ups THM10C or THM20C. • The following elements are required for securely installing the profile sections: – Straight section with fixed profile section TIS10A008-Pxx: 2 pieces / meter – Curve with flexible profile section TIS10A008-Fxx: 3 pieces / meter [2] [1] [9] [3] [4] [5] [6] [7] [8] [9] 57970AXX Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 11 Installation Unit designation, nameplates and scope of delivery 3 Mounting dimensions The following figure shows the mounting dimensions of the completely assembled profile sections. 74 74 33 33 180 33 74 [A] [B] [C] 58064AXX 12 [A] AFT-Profil 180 with matching support (...H00-0) and profile section [B] Cinetic-Profil 180 with matching support (...-H01-0) and profile section [C] Dürr-Profil 180 with matching support (...-H02-0) and profile section Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Installation Unit designation, nameplates and scope of delivery Scope of delivery installation equipment TIS10A008... for universal installation 3 The installation equipment TIS10A008.. (support, profile sections, retaining plates, cable bushings) are suited for universal installation to machines. If intended for installation on a steel construction, you have to use a shielding plate (not included in the delivery → Sec. "Technical Data"). Pos. Unit designation Support complete with two rotary supports, matching universal retaining plate Installation equipment [3] TIS10A008-H02-0 Fixed profile section, installation dimensions 33 mm, 3 m long [5] TIS10A008-P33-0 Fixed profile section, installation dimensions 74 mm, 3 m long [4] TIS10A008-P74-0 Flexible profile section, installation dimensions 33 mm, 2.2 m long [6] TIS10A008-F33-0 Flexible profile section, installation dimensions 74 mm, 2.2 m long [7] TIS10A008-F74-0 Cable bushing grommet [1] TIS10A008-A00-0 Cable entry frame for line cable 8 mm2 [2] TIS10A008-A74-0 Universal retaining plate [9] TIS10A-008-XH2-0 Shielding plate for installation on a steel construction (not included in the delivery) [8] - • The installation equipment TIS10A008... may only be used with pick-ups THM10C or THM20C. • You need the following support elements for securely installing the profile sections: – Straight track with fixed profile section TIS10A008-Pxx: 2 pieces / meter – Curve with profile section flexible TIS10A008-Fxx: 3 pieces / meter [A] Installation on aluminum construction [B] Installation on steel construction [B] [A] [1] [2] [3] [9] [4] [5] [6] [7] [3] [9] [4] 59302AXX Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS [5] [6] [7] [8] 59310AXX 13 Installation Unit designation, nameplates and scope of delivery 3 Mounting dimensions The following figure shows the mounting dimensions of the completely mounted profile section with the universal retaining plate TIS10008-XH2-0 for the support TIS10A008H02-0 74 33 74 33 120 [A] [B] 59325AXX 14 [A] Installation on aluminum profile [B] Installation with shielding plate on steel construction Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Installation Support for profile section (TIS10A...-H..-0) 3.2 3 Support for profile section (TIS10A...-H..-0) UL approval The UL approval has been granted for the plastic material used in supports TIS10A...H..-0. Description The support TIS10A...-H..-0 will fasten the profile section (cable duct) TIS10A...-P..0/F..-0 (→ Section "Profile section TIS10A...-P..-0/F..-0"). The support comes with two rotary elements. [1] [2] [3] 58925AXX [1] TIS10A008-H00-0 matching AFT-Profil180 [2] TIS10A008-H01-0 matching Cinetic-Profil 180 [3] TIS10A008-H02-0 matching Dürr-Profil 180 and universal support Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 15 Installation Profile section (TIS10A...-P..-0/F..-0) 3 3.3 Profile section (TIS10A...-P..-0/F..-0) UL approval The UL approval has been granted for the plastic material used of the profile section TIS10A...-P..-0/F.. Fixed profile section TIS10A-...-P..-0 The profile section TIS10A...-P..-0 in fixed design supports the line cable preferably for straight sections. [1] [2] 58926AXX [1] TIS10A008-P33-0 [2] TIS10A008-P74-0 16 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Installation Profile section (TIS10A...-P..-0/F..-0) Flexible profile section TIS10A-...-F..-0 3 The profile section TIS10A...-F..-0 in flexible design supports the line cable preferably for curved sections. [1] [2] 57733AXX [1] TIS10A008-F33-0 [2] TIS10A008-F74-0 Installing profile section TIS10A...P../F..-0 The following figure shows the basic approach to installing a profile section TIS10A...P..-0/F..-0 to the matching support TIS10A..-H..-0. [B] [A] [1] [2] [3] [4] [1] [2] [3] [4] 57745AXX [1] Installation profile [2] Support TIS10A...-H..-0 [3] Rotary support [4] Profile section TIS10A...-P..-0/F..-0 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 17 Installation Cable bushings for line cables (TIS10A...-A..-0) 3 3.4 Cable bushings for line cables (TIS10A...-A..-0) UL approval The UL approval has been granted for the plastic material used in the cable bushing frames TIS10A008-A74-0. Description You use the cable bushing TIS10A...-A..-0 in case you have to interrupt the line cable track. This is the case: • in the point area of a line cable section, • in case of connection to a compensation box TCS10A or an connection distributor TVS10A, • at the end of a line cable track (track termination). [1] [2] 58928AXX [1] TIS10A008-A00-0 (cable bushing grommet) [2] TIS10A008-A74-0 (cable bushing frame for line cable 8 mm2) 18 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Installation TCS10A... compensation box 3.5 3 TCS10A... compensation box Description The TCS10A compensation box is used to compensate the track inductance. [3] [1] [2] [2] [3] 56902AXX [1] TCS10A compensation box [2] Left / right flange plate [3] PE connection (M5) Connect the PE connection (cable cross section 16 mm2) with protective earth. Number and size of blanking plugs Compensation box type TCS10A-E06-090-1 TCS10A -E08-120-1 TCS10A -E08-120-2 Number and size of blanking plugs Left flange plate Right flange plate 4xM25 4xM25 2xM32 2xM32 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 19 Installation TVS10A connection distributor 3 3.6 TVS10A connection distributor Description The TVS10A connection distributor is used to: • Connect the TLS10E 006-06-01 supply cable (supply cabinet → power transmission system). • Couple the line cables to the power transmission system. [4] [1] [3] [2] [4] 56903AXX [1] TVS10A connection distributor [2] Right flange plate [3] Left flange plate [4] PE connection (M5) Connect the PE connection (cable cross section 16 mm2) with protective earth. Number and size of blanking plugs Connection distributor type TVS10A-E08-000-1 TVS10A-E08-000-1 TVS10A-E08-000-2 20 Number and size of blanking plugs Left flange plate Right flange plate 2xM32 4xM25 2xM32 2xM32 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Installation Retaining plate TIS10A...-X..-0 3.7 3 Retaining plate TIS10A...-X..-0 Description The retaining plate TIS10A008-X0.-0 is used to fasten a TCS10A compensation box or a TVS10A connection distributor to an aluminum profile. A separate, matching retaining plate is available for the various aluminum profiles of the different manufacturers. The retaining plate TIS10A...-X0.-0 is supplied with two M6x25 socket head screws. The universal retaining plate TIS10A008-XH2 is used to fasten the TIS10A008-H020 support to an aluminum or steel construction if no aluminum profile is available. [1] [2] [3] [4] 59298AXX [1] TIS10A008-X00-0 matching AFT aluminum profile rail 180 [2] TIS10A008-X01-0 matching Cinetic aluminum profile rail 180 [3] TIS10A008-X02-0 matching Dürr aluminum profile rail 180 [4] TIS10A008-XH2-0 to secure support TIS10A008-H02-0 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 21 Installation TLS10E line cables and supply cable 3 3.8 TLS10E line cables and supply cable UL approval UL approval for the TLS10E line cable has been granted. [1] [2] [3] [4] 56894AXX Description [1] [2] [3] [4] 22 TLS10E 008-01-1: • Medium-frequency cable (line cable) for THM pick-up • Cable cross section 8 mm2 • Laid as current loops in plastic profile TLS10E 016-01-1: • Medium-frequency cable (line cable) for THM pick-up • Cable cross section 16mm2 • Laid in or on the floor TLS10E 025-01-1 / TLS10E 041-01-1: • Medium-frequency cable (line cable) for THM pick-up • Cable cross section 25 mm2 / Cable cross section 41 mm2 • Laid as current loops in or on the floor TLS10E 006-06-1: • Fine litz wires as supply cable from supply cabinet → power transmission system • Cable cross section 6 × 6 mm2 • Fixed installation, e.g. in cable duct or as a cable carrier application Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Installation Required tools 3.9 3 Required tools Tools for prefabricating line cables: [1] [2] [4] [3] [5] [6] 56977AXX [1] Diagonal cutter [4] Soldering pot with solder [2] Knife [5] Hatchet-type soldering iron with solder [3] Shrink tubing [6] Vise Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 23 Installation Prefabricating TLS10E line cables 3 3.10 Prefabricating TLS10E line cables Line cable The line cables used in the MOVITRANS® system are medium-frequency cables. The core of the medium-frequency cable is made up of several thin wires isolated against one another by a coating. They are protected against contact with double insulation. Prefabrication A soldering pot or hatchet-type soldering iron are most suited to prefabricating line cables. Do not press the cable lugs. Soldering cable lugs Solder the end of the cable to the cable lug. Preparing the connection sections The connection sections are prepared in a number of steps. Proceed as follows: This is the only way to ensure that the transfer resistance is sufficiently low. 1. Push the shrinking tube over the cable end. 2. Mark the length to be stripped. 56153AXX 3. Strip the cable end. 56154AXX 24 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Installation Prefabricating TLS10E line cables 3 4. Solder the stripped cable end using a soldering pot or hatchet-type soldering iron (→ following illustrations). With a hatchet-type soldering iron (→ figure A): Pour the solder into the cable lug to halfway and then insert the stripped cable end in the cable lug. Heat the cable lug until the insulation (coating) of the individual wires melts and leaks out of the cable lug as brown waste. With soldering pot (→ figure B): Hold the stripped cable end in the soldering pot until the insulation (coating) of the individual wires melts and floats to the top of the soldering cup. A B 56975AXX 5. During the soldering processing, to ensure a sufficiently good connection ensure that the insulation (coating) of the individual wires does not remain in the cable lug. 56156AXX Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 25 Installation Connecting the TLS line cable to TCS10A / TVS10A 3 6. Push the shrinking tube over the soldering point. 7. Heat the shrink tubing until it closes tightly around the soldering point. 56157AXX 3.11 Connecting the TLS line cable to TCS10A / TVS10A 1. Remove the blanking plugs according to the number of line cables to be connected. 2. Insert the correct number of M25 (TCS10A) or M25/M32 (TVS10A) cable glands in place of the blanking plugs. 3. Open the unit by removing the four M5 hex head screws from the housing cover. 4. Insert the prefabricated line cable through the cable gland into the TCS/TVS wiring space. 5. Connecting the TLS line cable to TCS10A: – Remove the two M8 combi pan head screws from the connector plate of the TCS10A. – Connect the line cables prefabricated with cable lugs to the terminal studs. Screw the two combi pan head screws back into the terminal studs. The line cables are now in place. 56978AXX Figure 3: Line cables connected to the TCS10A 26 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Installation Prefabricating the TLS10E006-06-1 supply cable 3 6. Connecting the TLS line cable to TVS10A: – On the terminal board, unscrew the M6 hex nuts from the connection stud bolts. The number of nuts to be removed depends on the number of cable lines to be connected. – Connect the jumpers according to the circuit diagram. – Connect the line cables prefabricated with cable lugs to the connection stud bolts on the terminal board. Screw the M6 hex nuts back onto the connection stud bolts. The line cables are now in place. 58098AXX Figure 4: Completely connected line cable on TVS10A for 60 A line cable current 58099AXX Figure 5: Completely connected line cable on TVS10A for 85 A line cable current 7. Install the housing cover again using the four M5 hex head screws. 3.12 Prefabricating the TLS10E006-06-1 supply cable Incoming cable The supply cable (supply cabinet → power transmission system) is a six-core cable. There are 3 blue cores and 3 black ones. Three cores of the same color are used as outgoing cables or return cables and are connected to the TVS10A in parallel. Prefabrication In the supply cable, the conductor wires are not insulated against one another. Unlike the line cables, the cable lugs can be pressed together with the core ends of a supply cable using a standard tool. Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 27 3 Installation Connecting the TLS10E006-06-1 supply cable to TVS10A 3.13 Connecting the TLS10E006-06-1 supply cable to TVS10A 1. Remove one blanking plug (M32) from the TVS10A. 2. Insert an M32 cable gland in place of the blanking plug. 3. Open the unit by removing the four M5 hex head screws from the housing cover. 4. Press a ring cable lug (6 mm2 with 6 mm hole) onto each of the six cores of the supply cable. 5. Insert the supply cable that is prefabricated with cable lugs through the cable gland and into the wiring space of the TVS10A. 6. Connect the TLS10E006-06-1 supply cable to TVS10A: – On the terminal board, unscrew the M6 hex nuts from the connection stud bolts. The number of nuts to be removed depends on the number of cable lines to be connected. – Connect the jumpers according to the circuit diagram. – Connect three cores of the supply cable that are the same color, prefabricated with cable shoes, to the connection stud bolts on the terminal board. Screw the M6 hex nuts back onto the connection stud bolts. The supply cable is now in place. 7. Install the housing cover again using the four M5 hex head screws. 28 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Technical Data Medium-frequency cable, cable lugs and cable glands 4 Technical Data 4.1 Medium-frequency cable, cable lugs and cable glands kVA i n f 4 P Hz For connecting the medium-frequency cable to TVS10A using M6 terminal studs: Line cable type Cable cross section TLS10E006-06-1 Outer diameter Cable lug [mm2] [mm] Type 6×6 20.5 Klauke 1R/6 Cable gland Clamping area Width [mm] (Plastic) [mm] 12 M32 15 ... 25 M20 8 ... 13 M25 11 ... 17 TLS10E008-01-1 8 8.6 ± 0.3 Klauke 3R/6 12 TLS10E016-01-1 16 11.0 ± 0.3 Klauke 4R/6 14 TLS10E025-01-1 25 12.4 ± 0.3 Klauke 5SG/6 TLS10E041-01-1 41 15.9 ± 0.4 Klauke 6SG/6 15 For connecting the medium-frequency cable to TCS10A / TAS10A (4 kW) using M8 terminal studs: Line cable type TLS10E006-06-1 Cable cross section Outer diameter Cable lug Application [mm2] [mm] Type 6 20.5 Klauke 1R/8 15 TAS10A (4 kW) Width [mm] TLS10E008-01-1 8 8.6 ± 0.3 Klauke 3R/8 15 TLS10E016-01-1 16 11.0 ± 0.3 Klauke 4R/8 16 TLS10E025-01-1 25 12.4 ± 0.3 Klauke 5R/8 TLS10E041-01-1 41 15.9 ± 0.4 Klauke 6SG/8 17 Cable gland Clamping area (Plastic) [mm] - - TCS10A M20 8 ... 13 TCS10A TAS10A (4 kW) M25 11 ... 17 For connecting the medium-frequency cable to TAS10A (16 kW) using M10 terminal studs: Type Cable cross section Outer diameter 2 [mm ] Cable lug [mm] TLS10E006-06-1 6 20.5 Type Width [mm] Klauke 1R/10 17 18 TLS10E016-01-1 16 11.0 ± 0.3 Klauke 4R/10 TLS10E025-01-1 25 12.4 ± 0.3 Klauke 5R/10 TLS10E041-01-1 41 15.9 ± 0.4 Klauke 6SG/10 4.2 19 Electrical properties and approvals of medium-frequency cables Type Insulation / sheathing material Electrical cable losses [W/track meter] TLS10E006-06-1 Operating voltage Installation type [V] Bending radius [mm] 14 (at 60 A) 1000 600 Fixed or flexible 8 (at 30 A) 1000 Fixed 8 (at 60 A) 1000 40 TLS10E025-01-1 5 (at 60 A) 10 (at 85 A) 1000 45 TLS10E041-01-1 6 (at 85 A) 1000 60 TLS10E008-01-1 TLS10E016-01-1 Thermoplast / Polyurethane Approval Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 80 UL CSA 35 UL 29 kVA 4 i 4.3 4.4 f n Technical Data UL approvals P Hz UL approvals Type Component UL approval TIS10A...-P-../F..-0 Profile section UL94-V0 TIS10A...-H..-0 Supports for profile section UL94-V0 E UL94-V0 TIS10A...-A..-0 Cable entry frame UL94-V0 Dimension drawing TCS10A / TVS10A 100 115,5 100 5 76 Complete unit TCS10A/TVS10A 6,5 A B 210 227 240 56846BXX Blanking plugs TCS10A...-1 A B 80 80 ,5 35 x) M 25 x1 (4 x) 25 x1 ,5 38 (4 38 35 M 57912AXX A = Left flange plate B = Right flange plate 30 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS kVA Technical Data Dimension drawing TCS10A / TVS10A i f n 4 P Hz Blanking plugs TVS10A...-1 B A 75 80 35 x) M 1,5 (2x )M 32 x 40 1,5 32 38 (4 x 25 57913AXX A = Left flange plate B = Right flange plate Blanking plugs TVS10A...-2, TCS10A...-2 A B 80 (2 80 x) ,5 32 x1 x 1, 5 45 45 ) (2x 2 M3 M 57914AXX A = Left flange plate B = Right flange plate Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 31 kVA 4 i 4.5 f n Technical Data Dimension drawings of supports for profile sections TIS10A...-H..-0 P Hz Dimension drawings of supports for profile sections TIS10A...-H..-0 Matching AFT-Profil 180: 160 100 50 120 14 19 23 40 Dimension drawing support TIS10A008-H00-0 57751AXX Matching Cinetic-Profil 180: 152 100 50 128 14 19 40 Dimension drawing support TIS10A008-H01-0 57752AXX Matching Dürr-Profil 180 and universal retaining plate: 153,6 100 50 120 11 14 19 40 Dimension drawing support TIS10A008-H02-0 57755AXX 32 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Technical Data Dimension drawings profile sections in fixed design TIS10A...-P..-0 4.6 kVA i f n 4 P Hz Dimension drawings profile sections in fixed design TIS10A...-P..-0 Dimension drawing profile section TIS10A008-P33-0 15,45 +5 0 18,1 3000 57756AXX Dimension drawing profile section TIS10A008-P74-0 15,09 +5 0 59,47 3000 57757AXX Dimension drawings of profile sections in flexible design TIS10A...-F..-0 Dimension drawing profile section TIS10A008-F33-0 2200 15,45 4 18,1 11,15 4.7 37,29 54x39,29 57759AXX Dimension drawing profile section TIS10A008-F74-0 2200 4 50 59,47 15,09 40,82 54x39,29 57760AXX Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 33 kVA 4 i 4.8 f n Technical Data Dimension drawings of cable bushings TIS10A...-A..-0 P Hz Dimension drawings of cable bushings TIS10A...-A..-0 Ø13 Dimension drawing grommet TIS10A008-A00-0 3 8 Ø9,5 14 Ø17,5 57762AXX 8,5 74 Dimension drawing cable bushing frame TIS10A008-A74-0 Ø11,8 Ø11,8 55,5 14 35 70,5 57763AXX 34 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Technical Data Dimension drawings of retaining plates TIS10A...-X..-0 4.9 kVA i f n 4 P Hz Dimension drawings of retaining plates TIS10A...-X..-0 Dimension drawing retaining plate TIS10A008-X00-0 Matching AFT-Profil 180 109,5 76 Ø5,5 16 5,75 18 M6 92,5 57765AXX Dimension drawing retaining plate TIS10A008-X01-0 Matching Cinetic-Profil 180 151 76 Ø5,5 1,4 12,5 25 M6 92,6 114,9 134,4 57766AXX Dimension drawing retaining plate TIS10A008-X02-0 Matching Dürr-Profil 180 154 76 Ø5,5 15,3 4,6 25 M6 92,6 120,6 139,4 57768AXX Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 35 kVA n Technical Data Dimension drawing of shielding plate P Hz Matching support TIS10A008-H02-0. 145 130 75 Dimension drawing universal retaining plate TIS10A008-XH2-0 60 i f 45 4 45 5 5. Ø 154 59301AXX 4.10 Dimension drawing of shielding plate If you install the universal retaining plate to a steel construction, you will have to use a shielding plate as shown in the following figure. 3 5.5 90 130 220 90 150 ° Ø 5 Ø [1] [1] R1 10 .5 [1] Fastening for universal retaining plate TIS10A008-XH2-0 ° 25 220 120 60 500 60 720 975 1000 59314AXX The shielding plate is not included in the scope of delivery. 36 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Index of Changes Changes to the previous version 5 Index of Changes 5.1 Changes to the previous version 5 The following section lists the changes from edition 06/2005, publication number 11352213 (EN). • The following installation equipment was added to the Installation and Technical Data sections: – – – – – Support for profile section TIS10A...-H..-0 Profile section TIS10A...-P..-0/F..-0 Cable bushing for line cables TIS10A...-A..-0 Retaining plate TIS10A...-X..-0 New types of the TCS10A compensation box and TVS10A connection distributor Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 37 6 Index 6 Index A Application environment ........................................5 C Cable bushings TIS10A...-A..-0 Structure .......................................................18 Cable glands Technical data ..............................................29 Cable lugs Technical data ..............................................29 Compensation box TCS10A ...............................10 Connection distributor TVS10A ...........................10 D Designated use .....................................................4 Dimension drawings Blanking plugs TCS10A...-1 .........................30 Blanking plugs TCS10A...-2, TVS10A...-2 ....31 Blanking plugs TVS10A...-1 ..........................31 Cable bushings (TIS10A...-A..-0) ..................34 Profile sections in fixed design (TIS10A...-P..-0) ..............................33 Profile sections in flexible design (TIS10A...-F..-0) ...............................33 Screening plate .............................................36 Supports for profile sections (TIS10A...-H..-0) ..............................32 TCS10A/TVS10A ..........................................30 Disposal ................................................................5 I Index of changes .................................................37 Changes to the previous version ..................37 Installation components TIS10A Scope of delivery ..........................................13 Installation equipment TIS10A Scope of delivery ..........................................11 Unit designation ..............................................9 L Line cable TLS10E Scope of delivery ..........................................10 M Medium-frequency cable Electrical properties and approvals ..............29 Technical data ..............................................29 N Nameplates TCS10A, TVS10A .............................8 P Prefabricating line cables TLS10E ......................24 Profile section TIS10A...-P..-0/F..-0 Structure .......................................................16 38 R Retaining plate TIS10A...-B..-0 Structure ...................................................... 21 S Safety instructions ................................................ 4 Safety notes Installation and startup ................................... 6 Operation and service .................................... 6 Scope of delivery ................................................ 10 Compensation box TCS10A ........................ 10 Connection distributor TVS10A ................... 10 Installation equipment TIS10A ............... 11, 13 Line cable TLS10E ...................................... 10 Supports for profile section TIS10A...-H..-0 Structure ...................................................... 15 T TCS10A Nameplate ..................................................... 8 Scope of delivery ......................................... 10 Structure ...................................................... 19 Unit designation ............................................. 7 TCS10A compensation box Structure ...................................................... 19 Technical data Dimension drawing blanking plugs TCS10A...-1 .................................... 30 Dimension drawing blanking plugs TCS10A...-2, TVS10A...-2 .............. 31 Dimension drawing screening plate ............. 36 Dimension drawing TCS10A/TVS10A ......... 30 Dimension drawing TVS10A...-1 .................. 31 Dimension drawings profile sections in fixed design (TIS10A...-P..-0) ......... 33 Dimension drawings profile sections in flexible design (TIS10A...-F..-0) ...... 33 Dimension drawings retaining plates (TIS10A...-X..-0) .............................. 35 Dimension drawings support for profile sections (TIS10A...-H..-0) .... 32 Dimension sheets cable bushings (TIS10A...-A..-0) .............................. 34 Electrical properties and approvals of medium-frequency cables ............... 29 Medium-frequency cable, cable lugs and cable glands ............................................. 29 UL approvals ................................................ 30 TIS10A Scope of delivery ................................... 11, 13 Unit designation ............................................. 9 TLS10E Connecting to TCS10A /TVS10A ................. 26 Overview of line cables ................................ 22 Prefabrication ............................................... 24 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS Index 6 Preparing the connection sections ...............24 Scope of delivery ..........................................10 Soldering the cable lugs with a hatchet-type soldering iron ...................................25 Soldering the cable lugs with the soldering pot ....................................25 Tools for prefabrication .................................23 Unit designation ..............................................8 TLS10E line cable Design ..........................................................22 TLS10E line cables Connecting to TCS10A / TVS10A ................26 Prefabrication ...............................................24 Preparing the connection sections ...............24 Soldering the cable lugs with a hatchet-type soldering iron ...................................25 Soldering the cable lugs with the soldering pot ....................................25 Tools for prefabrication .................................23 TLS10E006-06-1 Connecting to TVS10A .................................28 Prefabrication ...............................................27 TLS10E006-06-1 supply cable Connecting to TVS10A .................................28 Prefabrication ...............................................27 Tools required for prefabrication of TLS10E line cables ...........................................................23 TVS10A Nameplate ......................................................8 Scope of delivery ..........................................10 Structure .......................................................20 Units designation ............................................7 TVS10A connection distributor Structure .......................................................20 U Unit designation Compensation box TCS10A ...........................7 Connection distributors TVS10A ....................7 Installation equipment TIS10A ........................9 Line cable TLS10E .........................................8 W Warning instructions .............................................4 Operating Instructions – MOVITRANS® Installation Equipment TCS, TIS, TLS, TVS 39 Address List Address List Germany Headquarters Production Sales Bruchsal SEW-EURODRIVE GmbH & Co KG Ernst-Blickle-Straße 42 D-76646 Bruchsal P.O. Box Postfach 3023 • D-76642 Bruchsal Tel. +49 7251 75-0 Fax +49 7251 75-1970 http://www.sew-eurodrive.de [email protected] Service Competence Center Central Gear units / Motors SEW-EURODRIVE GmbH & Co KG Ernst-Blickle-Straße 1 D-76676 Graben-Neudorf Tel. +49 7251 75-1710 Fax +49 7251 75-1711 [email protected] Central Electronics SEW-EURODRIVE GmbH & Co KG Ernst-Blickle-Straße 42 D-76646 Bruchsal Tel. +49 7251 75-1780 Fax +49 7251 75-1769 [email protected] North SEW-EURODRIVE GmbH & Co KG Alte Ricklinger Straße 40-42 D-30823 Garbsen (near Hannover) Tel. +49 5137 8798-30 Fax +49 5137 8798-55 [email protected] East SEW-EURODRIVE GmbH & Co KG Dänkritzer Weg 1 D-08393 Meerane (near Zwickau) Tel. +49 3764 7606-0 Fax +49 3764 7606-30 [email protected] South SEW-EURODRIVE GmbH & Co KG Domagkstraße 5 D-85551 Kirchheim (near München) Tel. +49 89 909552-10 Fax +49 89 909552-50 [email protected] West SEW-EURODRIVE GmbH & Co KG Siemensstraße 1 D-40764 Langenfeld (near Düsseldorf) Tel. +49 2173 8507-30 Fax +49 2173 8507-55 [email protected] Drive Service Hotline / 24 Hour Service +49 180 5 SEWHELP +49 180 5 7394357 Additional addresses for service in Germany provided on request! France Production Sales Service Haguenau SEW-USOCOME 48-54, route de Soufflenheim B. P. 20185 F-67506 Haguenau Cedex Tel. +33 3 88 73 67 00 Fax +33 3 88 73 66 00 http://www.usocome.com [email protected] Assembly Sales Service Bordeaux SEW-USOCOME Parc d'activités de Magellan 62, avenue de Magellan - B. P. 182 F-33607 Pessac Cedex Tel. +33 5 57 26 39 00 Fax +33 5 57 26 39 09 Lyon SEW-USOCOME Parc d'Affaires Roosevelt Rue Jacques Tati F-69120 Vaulx en Velin Tel. +33 4 72 15 37 00 Fax +33 4 72 15 37 15 Paris SEW-USOCOME Zone industrielle 2, rue Denis Papin F-77390 Verneuil I'Etang Tel. +33 1 64 42 40 80 Fax +33 1 64 42 40 88 Additional addresses for service in France provided on request! Algeria Sales Alger Réducom 16, rue des Frères Zaghnoun Bellevue El-Harrach 16200 Alger Tel. +213 21 8222-84 Fax +213 21 8222-84 Buenos Aires SEW EURODRIVE ARGENTINA S.A. Centro Industrial Garin, Lote 35 Ruta Panamericana Km 37,5 1619 Garin Tel. +54 3327 4572-84 Fax +54 3327 4572-21 [email protected] Argentina Assembly Sales Service 40 Address List Australia Assembly Sales Service Melbourne SEW-EURODRIVE PTY. LTD. 27 Beverage Drive Tullamarine, Victoria 3043 Tel. +61 3 9933-1000 Fax +61 3 9933-1003 http://www.sew-eurodrive.com.au [email protected] Sydney SEW-EURODRIVE PTY. LTD. 9, Sleigh Place, Wetherill Park New South Wales, 2164 Tel. +61 2 9725-9900 Fax +61 2 9725-9905 [email protected] Townsville SEW-EURODRIVE PTY. LTD. 12 Leyland Street Garbutt, QLD 4814 Tel. +61 7 4779 4333 Fax +61 7 4779 5333 [email protected] Wien SEW-EURODRIVE Ges.m.b.H. Richard-Strauss-Strasse 24 A-1230 Wien Tel. +43 1 617 55 00-0 Fax +43 1 617 55 00-30 http://sew-eurodrive.at [email protected] Brüssel SEW Caron-Vector S.A. Avenue Eiffel 5 B-1300 Wavre Tel. +32 10 231-311 Fax +32 10 231-336 http://www.caron-vector.be [email protected] Sao Paulo SEW-EURODRIVE Brasil Ltda. Avenida Amâncio Gaiolli, 50 Caixa Postal: 201-07111-970 Guarulhos/SP - Cep.: 07251-250 Tel. +55 11 6489-9133 Fax +55 11 6480-3328 http://www.sew.com.br [email protected] Austria Assembly Sales Service Belgium Assembly Sales Service Brazil Production Sales Service Additional addresses for service in Brazil provided on request! Bulgaria Sales Sofia BEVER-DRIVE GmbH Bogdanovetz Str.1 BG-1606 Sofia Tel. +359 2 9151160 Fax +359 2 9151166 [email protected] Douala Electro-Services Rue Drouot Akwa B.P. 2024 Douala Tel. +237 4322-99 Fax +237 4277-03 Toronto SEW-EURODRIVE CO. OF CANADA LTD. 210 Walker Drive Bramalea, Ontario L6T3W1 Tel. +1 905 791-1553 Fax +1 905 791-2999 http://www.sew-eurodrive.ca [email protected] Vancouver SEW-EURODRIVE CO. OF CANADA LTD. 7188 Honeyman Street Delta. B.C. V4G 1 E2 Tel. +1 604 946-5535 Fax +1 604 946-2513 [email protected] Montreal SEW-EURODRIVE CO. OF CANADA LTD. 2555 Rue Leger Street LaSalle, Quebec H8N 2V9 Tel. +1 514 367-1124 Fax +1 514 367-3677 [email protected] Cameroon Sales Canada Assembly Sales Service Additional addresses for service in Canada provided on request! Chile Assembly Sales Service Santiago de Chile SEW-EURODRIVE CHILE LTDA. Las Encinas 1295 Parque Industrial Valle Grande LAMPA RCH-Santiago de Chile P.O. Box Casilla 23 Correo Quilicura - Santiago - Chile Tel. +56 2 75770-00 Fax +56 2 75770-01 www.sew-eurodrive.cl [email protected] 41 Address List China Production Assembly Sales Service Tianjin SEW-EURODRIVE (Tianjin) Co., Ltd. No. 46, 7th Avenue, TEDA Tianjin 300457 Tel. +86 22 25322612 Fax +86 22 25322611 [email protected] http://www.sew-eurodrive.com.cn Assembly Sales Service Suzhou SEW-EURODRIVE (Suzhou) Co., Ltd. 333, Suhong Middle Road Suzhou Industrial Park Jiangsu Province, 215021 P. R. China Tel. +86 512 62581781 Fax +86 512 62581783 [email protected] Additional addresses for service in China provided on request! Colombia Assembly Sales Service Bogotá SEW-EURODRIVE COLOMBIA LTDA. Calle 22 No. 132-60 Bodega 6, Manzana B Santafé de Bogotá Tel. +57 1 54750-50 Fax +57 1 54750-44 http://www.sew-eurodrive.com.co [email protected] Zagreb KOMPEKS d. o. o. PIT Erdödy 4 II HR 10 000 Zagreb Tel. +385 1 4613-158 Fax +385 1 4613-158 [email protected] Praha SEW-EURODRIVE CZ S.R.O. Business Centrum Praha Luzna 591 CZ-16000 Praha 6 - Vokovice Tel. +420 220121234 Fax +420 220121237 http://www.sew-eurodrive.cz [email protected] Kopenhagen SEW-EURODRIVEA/S Geminivej 28-30, P.O. Box 100 DK-2670 Greve Tel. +45 43 9585-00 Fax +45 43 9585-09 http://www.sew-eurodrive.dk [email protected] Tallin ALAS-KUUL AS Mustamäe tee 24 EE-10620Tallin Tel. +372 6593230 Fax +372 6593231 [email protected] Lahti SEW-EURODRIVE OY Vesimäentie 4 FIN-15860 Hollola 2 Tel. +358 201 589-300 Fax +358 3 780-6211 [email protected] http://www.sew-eurodrive.fi Libreville Electro-Services B.P. 1889 Libreville Tel. +241 7340-11 Fax +241 7340-12 Normanton SEW-EURODRIVE Ltd. Beckbridge Industrial Estate P.O. Box No.1 GB-Normanton, West- Yorkshire WF6 1QR Tel. +44 1924 893-855 Fax +44 1924 893-702 http://www.sew-eurodrive.co.uk [email protected] Athen Christ. Boznos & Son S.A. 12, Mavromichali Street P.O. Box 80136, GR-18545 Piraeus Tel. +30 2 1042 251-34 Fax +30 2 1042 251-59 http://www.boznos.gr [email protected] Croatia Sales Service Czech Republic Sales Denmark Assembly Sales Service Estonia Sales Finland Assembly Sales Service Gabon Sales Great Britain Assembly Sales Service Greece Sales Service 42 Address List Hong Kong Assembly Sales Service Hong Kong SEW-EURODRIVE LTD. Unit No. 801-806, 8th Floor Hong Leong Industrial Complex No. 4, Wang Kwong Road Kowloon, Hong Kong Tel. +852 2 7960477 + 79604654 Fax +852 2 7959129 [email protected] Budapest SEW-EURODRIVE Kft. H-1037 Budapest Kunigunda u. 18 Tel. +36 1 437 06-58 Fax +36 1 437 06-50 [email protected] Assembly Sales Service Baroda SEW-EURODRIVE India Pvt. Ltd. Plot No. 4, Gidc Por Ramangamdi • Baroda - 391 243 Gujarat Tel. +91 265 2831086 Fax +91 265 2831087 http://www.seweurodriveindia.com [email protected] Technical Offices Bangalore SEW-EURODRIVE India Private Limited 308, Prestige Centre Point 7, Edward Road Bangalore Tel. +91 80 22266565 Fax +91 80 22266569 [email protected] Dublin Alperton Engineering Ltd. 48 Moyle Road Dublin Industrial Estate Glasnevin, Dublin 11 Tel. +353 1 830-6277 Fax +353 1 830-6458 Tel-Aviv Liraz Handasa Ltd. Ahofer Str 34B / 228 58858 Holon Tel. +972 3 5599511 Fax +972 3 5599512 [email protected] Milano SEW-EURODRIVE di R. Blickle & Co.s.a.s. Via Bernini,14 I-20020 Solaro (Milano) Tel. +39 02 96 9801 Fax +39 02 96 799781 http://www.sew-eurodrive.it [email protected] Abidjan SICA Ste industrielle et commerciale pour l'Afrique 165, Bld de Marseille B.P. 2323, Abidjan 08 Tel. +225 2579-44 Fax +225 2584-36 Toyoda-cho SEW-EURODRIVE JAPAN CO., LTD 250-1, Shimoman-no, Iwata Shizuoka 438-0818 Tel. +81 538 373811 Fax +81 538 373814 [email protected] Ansan-City SEW-EURODRIVE KOREA CO., LTD. B 601-4, Banweol Industrial Estate Unit 1048-4, Shingil-Dong Ansan 425-120 Tel. +82 31 492-8051 Fax +82 31 492-8056 http://www.sew-korea.co.kr [email protected] Riga SIA Alas-Kuul Katlakalna 11C LV-1073 Riga Tel. +371 7139253 Fax +371 7139386 http://www.alas-kuul.com [email protected] Hungary Sales Service India Ireland Sales Service Israel Sales Italy Assembly Sales Service Ivory Coast Sales Japan Assembly Sales Service Korea Assembly Sales Service Latvia Sales 43 Address List Lebanon Sales Beirut Gabriel Acar & Fils sarl B. P. 80484 Bourj Hammoud, Beirut Tel. +961 1 4947-86 +961 1 4982-72 +961 3 2745-39 Fax +961 1 4949-71 [email protected] Alytus UAB Irseva Naujoji 19 LT-62175 Alytus Tel. +370 315 79204 Fax +370 315 56175 [email protected] http://www.sew-eurodrive.lt Brüssel CARON-VECTOR S.A. Avenue Eiffel 5 B-1300 Wavre Tel. +32 10 231-311 Fax +32 10 231-336 http://www.caron-vector.be [email protected] Johore SEW-EURODRIVE SDN BHD No. 95, Jalan Seroja 39, Taman Johor Jaya 81000 Johor Bahru, Johor West Malaysia Tel. +60 7 3549409 Fax +60 7 3541404 [email protected] Queretaro SEW-EURODRIVE MEXIKO SA DE CV SEM-981118-M93 Tequisquiapan No. 102 Parque Industrail Queretaro C.P. 76220 Queretaro, Mexico Tel. +52 442 1030-300 Fax +52 442 1030-301 http://www.sew-eurodrive.com.mx [email protected] Casablanca Afit 5, rue Emir Abdelkader MA 20300 Casablanca Tel. +212 22618372 Fax +212 22618351 [email protected] Rotterdam VECTOR Aandrijftechniek B.V. Industrieweg 175 NL-3044 AS Rotterdam Postbus 10085 NL-3004 AB Rotterdam Tel. +31 10 4463-700 Fax +31 10 4155-552 http://www.vector.nu [email protected] Auckland SEW-EURODRIVE NEW ZEALAND LTD. P.O. Box 58-428 82 Greenmount drive East Tamaki Auckland Tel. +64 9 2745627 Fax +64 9 2740165 http://www.sew-eurodrive.co.nz [email protected] Christchurch SEW-EURODRIVE NEW ZEALAND LTD. 10 Settlers Crescent, Ferrymead Christchurch Tel. +64 3 384-6251 Fax +64 3 384-6455 [email protected] Moss SEW-EURODRIVE A/S Solgaard skog 71 N-1599 Moss Tel. +47 69 241-020 Fax +47 69 241-040 http://www.sew-eurodrive.no [email protected] Lima SEW DEL PERU MOTORES REDUCTORES S.A.C. Los Calderos, 120-124 Urbanizacion Industrial Vulcano, ATE, Lima Tel. +51 1 3495280 Fax +51 1 3493002 http://www.sew-eurodrive.com.pe [email protected] Lithuania Sales Luxembourg Assembly Sales Service Malaysia Assembly Sales Service Mexico Assembly Sales Service Morocco Sales Netherlands Assembly Sales Service New Zealand Assembly Sales Service Norway Assembly Sales Service Peru Assembly Sales Service 44 Address List Poland Assembly Sales Service Lodz SEW-EURODRIVE Polska Sp.z.o.o. ul. Techniczna 5 PL-92-518 Lodz Tel. +48 42 67710-90 Fax +48 42 67710-99 http://www.sew-eurodrive.pl [email protected] Coimbra SEW-EURODRIVE, LDA. Apartado 15 P-3050-901 Mealhada Tel. +351 231 20 9670 Fax +351 231 20 3685 http://www.sew-eurodrive.pt [email protected] Bucuresti Sialco Trading SRL str. Madrid nr.4 011785 Bucuresti Tel. +40 21 230-1328 Fax +40 21 230-7170 [email protected] St. Petersburg ZAO SEW-EURODRIVE P.O. Box 36 195220 St. Petersburg Russia Tel. +7 812 3332522 +7 812 5357142 Fax +7 812 3332523 http://www.sew-eurodrive.ru [email protected] Dakar SENEMECA Mécanique Générale Km 8, Route de Rufisque B.P. 3251, Dakar Tel. +221 849 47-70 Fax +221 849 47-71 [email protected] Beograd DIPAR d.o.o. Ustanicka 128a PC Košum, IV floor SCG-11000 Beograd Tel. +381 11 347 3244 / +381 11 288 0393 Fax +381 11 347 1337 [email protected] Singapore SEW-EURODRIVE PTE. LTD. No 9, Tuas Drive 2 Jurong Industrial Estate Singapore 638644 Tel. +65 68621701 Fax +65 68612827 http://www.sew-eurodrive.com.sg [email protected] Bratislava SEW-Eurodrive SK s.r.o. Rybnicna 40 SK-83107 Bratislava Tel. +421 2 49595201 Fax +421 2 49595200 http://www.sew.sk [email protected] Zilina SEW-Eurodrive SK s.r.o. ul. Vojtecha Spanyola 33 SK-010 01 Zilina Tel. +421 41 700 2513 Fax +421 41 700 2514 [email protected] Banská Bystrica SEW-Eurodrive SK s.r.o. Rudlovská cesta 85 SK-97411 Banská Bystrica Tel. +421 48 414 6564 Fax +421 48 414 6566 [email protected] Celje Pakman - Pogonska Tehnika d.o.o. UI. XIV. divizije 14 SLO - 3000 Celje Tel. +386 3 490 83-20 Fax +386 3 490 83-21 [email protected] Johannesburg SEW-EURODRIVE (PROPRIETARY) LIMITED Eurodrive House Cnr. Adcock Ingram and Aerodrome Roads Aeroton Ext. 2 Johannesburg 2013 P.O.Box 90004 Bertsham 2013 Tel. +27 11 248-7000 Fax +27 11 494-3104 http://www.sew.co.za [email protected] Portugal Assembly Sales Service Romania Sales Service Russia Assembly Sales Service Senegal Sales Serbia and Montenegro Sales Singapore Assembly Sales Service Slovakia Sales Slovenia Sales Service South Africa Assembly Sales Service 45 Address List South Africa Capetown SEW-EURODRIVE (PROPRIETARY) LIMITED Rainbow Park Cnr. Racecourse & Omuramba Road Montague Gardens Cape Town P.O.Box 36556 Chempet 7442 Cape Town Tel. +27 21 552-9820 Fax +27 21 552-9830 Telex 576 062 [email protected] Durban SEW-EURODRIVE (PROPRIETARY) LIMITED 2 Monaceo Place Pinetown Durban P.O. Box 10433, Ashwood 3605 Tel. +27 31 700-3451 Fax +27 31 700-3847 [email protected] Bilbao SEW-EURODRIVE ESPAÑA, S.L. Parque Tecnológico, Edificio, 302 E-48170 Zamudio (Vizcaya) Tel. +34 9 4431 84-70 Fax +34 9 4431 84-71 http://www.sew-eurodrive.es [email protected] Jönköping SEW-EURODRIVE AB Gnejsvägen 6-8 S-55303 Jönköping Box 3100 S-55003 Jönköping Tel. +46 36 3442-00 Fax +46 36 3442-80 http://www.sew-eurodrive.se [email protected] Basel Alfred lmhof A.G. Jurastrasse 10 CH-4142 Münchenstein bei Basel Tel. +41 61 417 1717 Fax +41 61 417 1700 http://www.imhof-sew.ch [email protected] Chon Buri SEW-EURODRIVE (Thailand) Ltd. Bangpakong Industrial Park 2 700/456, Moo.7, Tambol Donhuaroh Muang District Chon Buri 20000 Tel. +66 38 454281 Fax +66 38 454288 [email protected] Tunis T. M.S. Technic Marketing Service 7, rue Ibn EI Heithem Z.I. SMMT 2014 Mégrine Erriadh Tel. +216 1 4340-64 + 1 4320-29 Fax +216 1 4329-76 [email protected] Istanbul SEW-EURODRIVE Hareket Sistemleri San. ve Tic. Ltd. Sti. Bagdat Cad. Koruma Cikmazi No. 3 TR-34846 Maltepe ISTANBUL Tel. +90 216 4419163 / 164 3838014/15 Fax +90 216 3055867 [email protected] Dnepropetrovsk SEW-EURODRIVE Str. Rabochaja 23-B, Office 409 49008 Dnepropetrovsk Tel. +380 56 370 3211 Fax +380 56 372 2078 http://www.sew-eurodrive.ua [email protected] Greenville SEW-EURODRIVE INC. 1295 Old Spartanburg Highway P.O. Box 518 Lyman, S.C. 29365 Tel. +1 864 439-7537 Fax Sales +1 864 439-7830 Fax Manuf. +1 864 439-9948 Fax Ass. +1 864 439-0566 Telex 805 550 http://www.seweurodrive.com [email protected] Spain Assembly Sales Service Sweden Assembly Sales Service Switzerland Assembly Sales Service Thailand Assembly Sales Service Tunisia Sales Turkey Assembly Sales Service Ukraine Sales Service USA Production Assembly Sales Service 46 Address List USA Assembly Sales Service San Francisco SEW-EURODRIVE INC. 30599 San Antonio St. Hayward, California 94544-7101 Tel. +1 510 487-3560 Fax +1 510 487-6381 [email protected] Philadelphia/PA SEW-EURODRIVE INC. Pureland Ind. Complex 2107 High Hill Road, P.O. Box 481 Bridgeport, New Jersey 08014 Tel. +1 856 467-2277 Fax +1 856 845-3179 [email protected] Dayton SEW-EURODRIVE INC. 2001 West Main Street Troy, Ohio 45373 Tel. +1 937 335-0036 Fax +1 937 440-3799 [email protected] Dallas SEW-EURODRIVE INC. 3950 Platinum Way Dallas, Texas 75237 Tel. +1 214 330-4824 Fax +1 214 330-4724 [email protected] Additional addresses for service in the USA provided on request! Venezuela Assembly Sales Service Valencia SEW-EURODRIVE Venezuela S.A. Av. Norte Sur No. 3, Galpon 84-319 Zona Industrial Municipal Norte Valencia, Estado Carabobo Tel. +58 241 832-9804 Fax +58 241 838-6275 http://www.sew-eurodrive.com.ve [email protected] [email protected] 47 Gearmotors \ Industrial Gear Units \ Drive Electronics \ Drive Automation \ Services How we’re driving the world With people who think fast and develop the future with you. With a worldwide service network that is always close at hand. With drives and controls that automatically improve your productivity. With uncompromising quality that reduces the cost and complexity of daily operations. With comprehensive knowledge in virtually every branch of industry today. SEW-EURODRIVE Driving the world With a global presence that offers responsive and reliable solutions. Anywhere. With innovative technology that solves tomorrow’s problems today. With online information and software updates, via the Internet, available around the clock. SEW-EURODRIVE GmbH & Co KG P.O. Box 3023 · D-76642 Bruchsal / Germany Phone +49 7251 75-0 · Fax +49 7251 75-1970 [email protected] www.sew-eurodrive.com