Download FlexDrive Installation Manual
Transcript
Figure 3-27 Resolver Cable Connections for CE Installations R2 X8 S2 P R1 S4 P S3 S1 P 3 SIN+ 8 SIN- 2 COS+ 7 COS- 1 REF+ 6 REF- (Common) 5 P = Twisted Pair Connect overall shield to connector backshells AGND Connect internal shields to AGND X9 Handwheel (Encoder) Installation Handwheel Mode (Standard Encoder) Twisted pair shielded wire with an overall shield should be used. Figure 3-28 shows the electrical connections between the encoder and the encoder connector. Note: If the control was ordered with option E (Encoder/Hall feedback, catalog FDxAxxxx-Exxx) it is not possible to connect the handwheel. Figure 3-28 Differential Encoder Connections for UL Installations Encoder X9 1 6 2 7 3 8 11 13 A+ A-B+ B-C+ C-+5V DGND Shell (Chassis) Single Ended Connections Differential inputs are recommended for best noise immunity. If only single ended encoder signals are available, connect them to A, B, and C as shown in Figure 3-29. Figure 3-29 Single Ended Encoder Connections for UL Installations X9 Encoder MN1275 1 6 2 7 3 8 11 13 A B C +5V DGND Shell (Chassis) Receiving & Installation 3-19