Transcript
MLDL 2000 USER MANUAL Limitations of M2kM • Only one MLDL2000 can be connected to a PC. • There is no monitoring of plugging/unplugging MLDL2000, this may lead to a crash of the application and/or the PC. It is best to connect the MLDL2000 before starting M2kM, and to remove it after closing M2kM or use the Connection menu. • While communicating (meaning actively reading or programming) the MLDL2000 must be connected to the HP41. Do not run programs on the HP41 that use any of the MLDL2000 functions (like ROM images) while communicating. The MLDL2000 will be disabled while communicating, and no ROM images will be visible. • M2kM is tested only on Windows XP (SP2) • There is a very small (theoretical) possibility that other USB devices with the FT2232C controller are recognized as an MLDL2000 • The error checking and recovery of M2kM may not catch all possible errors. Reset FLASH if you suspect problems, for example after a FLASH programming time-out • FTDI offers a program for erasing and reprogramming of the EEPROM on the USB print. DO NOT USE THIS, or the MLDL2000 might not be able to work with M2kM again • In case of problems, check if you have the latest version of the FTDI drivers, the M2kM software and if all software and drivers are installed correctly • Verify only tests until the first faulty address, and will show the error address in the status bar • In the current version there is a possibility to test the MLDL2000, but the functionality is very limited. Version 1.51 Meindert Kuipers 10/23/2008 www.kuiprs.nl Page 35 of 40