Download Bladed for Windows User Manual
Transcript
Garrad Hassan and Partners Ltd Document:282/BR/010 ISSUE:11 FINAL In the window for the required post-processing calculation, click Multiple Channels to bring up the Multiple Processing window. Use the Add Load Case and Add Variable buttons to build up the required lists of load cases and variables. Add Many Load Cases allows all the calculations in a selected directory (including subdirectories if desired) to be added in one go. In most cases, multiple variables can be selected in one go by dragging over a number of variables, or holding down the Control key and clicking on the required variables. It is important to ensure that the output7.19 specifications for all the load cases are the same, i.e. the same outputs and the same blade and tower stations have been requested. If available, in the Load Cases window, enter the Occurrences per Year for transient load cases such as stops and starts, or the wind speed bin or number of hours per year which the load case is deemed to represent in the case of stationary load cases; click the button to select either wind speed bins or number of hours per year. It is possible to treat a stationary load case as transient, or vice versa, by clicking on the ‘S’ or ‘T’ indicator. At the bottom, enter the turbine lifetime, and ensure a wind speed distribution6.11 is defined. The wind speed distribution parameters will not be used if all the load cases are transient, and the length of transient simulations will not be included in the turbine lifetime. If available, for each variable, enter the number and range of the bins to be used. If the Minimum and Maximum are both left as zero, a bin range will be calculated which is suitable across all the load cases. For rainflow cycle and fatigue analysis, it is possible to specify a minimum range below which cycles are not counted. 8.16 Ultimate Loads This calculation scans a number of load cases to find the maximum and minimum values of a specified set of variables, and records the simultaneous values of all the other variables in the list. From the Ultimate Loads window, click Define Channels and Load Cases to open the Multiple Processing window. Use the Add Load Case and Add Variable buttons to build up the required lists of load cases and variables. For users with the Advanced Post Processing module, a list of Load Case Groups can be set up along with their corresponding safety factors. A check box on the Load Cases tab enables these to be assigned to the load cases. During processing the safety factors will then be applied. Safety factors may also be assigned to individual variables, and these will override the group safety factor. Each load case should have a unique identifier. If Load Case Groups have been defined, the identifier will attempt to set itself to a sensible default, which the user is free to change if required. For each variable, specify whether its maximum and minimum are to be found. An additional feature available to users with the Advanced Post Processing module is to combine blade loads across all blades. With this option the maximum and minimum loads across all blades will be reported. The output from this calculation consists of an ASCII text file with many rows and columns. The file name will be <directory> \ <run name> .$mx where the directory and run name are 93 of 116