Garrad Hassan and Partners Ltd
Document:282/BR/010
ISSUE:11
FINAL
In the window for the required post-processing calculation, click Multiple Channels to bring
up the Multiple Processing window. Use the Add Load Case and Add Variable buttons to
build up the required lists of load cases and variables. Add Many Load Cases allows all the
calculations in a selected directory (including subdirectories if desired) to be added in one go.
In most cases, multiple variables can be selected in one go by dragging over a number of
variables, or holding down the Control key and clicking on the required variables.
It is important to ensure that the output7.19 specifications for all the load cases are the same,
i.e. the same outputs and the same blade and tower stations have been requested.
If available, in the Load Cases window, enter the Occurrences per Year for transient load
cases such as stops and starts, or the wind speed bin or number of hours per year which the
load case is deemed to represent in the case of stationary load cases; click the
button to
select either wind speed bins or number of hours per year. It is possible to treat a stationary
load case as transient, or vice versa, by clicking on the ‘S’ or ‘T’ indicator. At the bottom,
enter the turbine lifetime, and ensure a wind speed distribution6.11 is defined. The wind speed
distribution parameters will not be used if all the load cases are transient, and the length of
transient simulations will not be included in the turbine lifetime.
If available, for each variable, enter the number and range of the bins to be used. If the
Minimum and Maximum are both left as zero, a bin range will be calculated which is suitable
across all the load cases. For rainflow cycle and fatigue analysis, it is possible to specify a
minimum range below which cycles are not counted.
8.16
Ultimate Loads
This calculation scans a number of load cases to find the maximum and minimum values of a
specified set of variables, and records the simultaneous values of all the other variables in the
list.
From the Ultimate Loads window, click Define Channels and Load Cases to open the
Multiple Processing window. Use the Add Load Case and Add Variable buttons to build
up the required lists of load cases and variables.
For users with the Advanced Post Processing module, a list of Load Case Groups can be
set up along with their corresponding safety factors. A check box on the Load Cases tab
enables these to be assigned to the load cases. During processing the safety factors will then
be applied. Safety factors may also be assigned to individual variables, and these will
override the group safety factor.
Each load case should have a unique identifier. If Load Case Groups have been defined, the
identifier will attempt to set itself to a sensible default, which the user is free to change if
required. For each variable, specify whether its maximum and minimum are to be found.
An additional feature available to users with the Advanced Post Processing module is to
combine blade loads across all blades. With this option the maximum and minimum loads
across all blades will be reported.
The output from this calculation consists of an ASCII text file with many rows and columns.
The file name will be <directory> \ <run name> .$mx where the directory and run name are
93 of 116