Electrical Installation Twin Disc, Incorporated 7. When all pins have been inserted in the connector body, reinsert the Deutsch locking wedge into the front of the connector body. 8. Ensure that sealing plugs are installed in all empty connector positions. 9. Align the harness connector with the J8 receptacle of the EC300 Control and push it in until it snaps into place. 10. Secure all harnesses to a supporting structure with clamps or cable ties at 406 mm (16 in.) intervals. Note: It may be desirable to complete any other terminations for this harness before securing the harness. EC300 Marine Control System Installation Manual #1024168 117