Download Lx Series User Manual - AMETEK Programmable Power
Transcript
User Manual Lx / Ls Series II Number Message String Cause test Remedy 43 "Current self test error, output 1 No. 1/A amplifier in Aux. Source has no output during Selftest. Contact AMETEK service department at [email protected] 44 "Current self test error, output 2 No. 2/B amplifier in Aux. Source has no output during Selftest. Contact AMETEK service department at [email protected] 45 "Current self test error, output 3 No. 3/C amplifier in Aux. Source has no output during Selftest. Contact AMETEK service department at [email protected] 216 " RS-232 receiver framing error" Communication failure. Check RS232 port settings and cable. 217 " RS-232 receiver parity error" Communication failure. Check RS232 port settings and cable. 218 " RS-232 receiver overrun error" Communication failure. Check RS232 port settings and cable. 402 "CAL password is incorrect" Calibration password does not equal high voltage range value. Re-enter correct password. 403 "CAL not enabled" No password entered for calibration Enter correct CAL password. 600 "Systems in mode:list have different list lengths" "Requested voltage and waveform exceeds peak voltage capability" Transient lists have unequal lengths Check list settings and correct to same no of data points. Wave shape selected and RMS voltage combine to exceed peak voltage capability. Reduce RMS or crest factor of wave shape. 602 "Requested voltage and waveform exceeds transformer volt-second rating" The selected wave shape exceeds output transformer capability. The volt-second product of he wave form (magnitude and time in the + and – half of wave form). 603 "Command only applies to RS-232 interface" Command not relevant for GPIB interface. Do not use command. 604 "Trigger received before requested number of pre-trigger readings" Data acquisition pretrigger buffer not filled yet. Hold off trigger or reduce pre-trigger delay. 605 "Requested RMS current too high for voltage range" Max RMS current is function of voltage range selected. Reduce programmed RMS current limit or select low voltage range. 606 "Waveform data not defined" No waveform name specified Specify waveform name before sending waveform data. 607 "VOLT,VOLT:SLEW, and FUNC:SHAPe modes incompatible" Conflict between wave shape and programmed slew Reduce slew or change waveform type. 608 "Measurement overrange" Measurement data out of range. 609 "Output buffer overrun" Too much data in 601 Check receive mode on application 217