Download FX2N-4AD SPECIAL FUNCTION BLOCK USER'S GUIDE
Transcript
5.3 Performance specification 3. WIRING Analog Inputs 1 Shielded This manual should be used by trained and competent personnel. The definition of such a person or persons is as follows: a) Any engineer using the product associated with this manual, should be of a competent nature, trained and qualified to the local and national standards. These engineers should be fully aware of all aspects of safety with regards to automated equipment. b) Any commissioning or service engineer must be of a competent nature, trained and qualified to the local and national standards. c) All operators of the completed equipment should be trained to use this product in a safe and coordinated manner in compliance to established safety practices. Note: The term ‘completed equipment’ refers to a third party constructed device which contains or uses the product associated with this manual. electrically induced noise on the external wiring, connect a smoothing capacitor of 0.1 to 0.47 µF, 25V. CH1 terminals to each other. 4 DC24V 55mA +15V 24+ 5 DC/DC AG converter 24- f If there is excessive electrical noise, connect the FG (frame ground) terminal with the grounded terminal on the FX2N-4AD. (In CH1, there is no FG terminal. Use FG terminal of other channels.) -15V Grounding (100: or less) FX2N-4AD Analog Input Block PLC g Connect the ground terminal on the FX2N-4AD unit with the grounded terminal on the main unit. Use grounding on the main unit, if available. Extension cable Digital output 12-bit conversion stored in 16-bit 2’s complement form. Maximum value: +2047 Minimum value: -2048 Resolution 5mV (10V default range 1/2000) 20µA (20mA default range 1/1000) Overall accuracy ± 1% (for the range of -10V to +10V) ± 1% (for the range of -20mA to +20mA) Conversion speed 15ms/channel (Normal speed), 6ms/channel (High speed) Analog Inputs continued... 4. CONNECTION WITH PLC Preset 0 (-10V to +10V) The FX2N-4AD unit can be connected to the PLCs as follows. Resrictions apply to the maximum number of connectable units, depending on the DC24V/DC5V Power Supply capacities and the Main Unit/Special Function Unit types. For details, refer to the respective PLC manual. +2,047 Digital output : The maximum connectable units is 4. To connect the FX2N-4AD with the FX2NC main unit, FX2NC-CNV-IF is required. FX1N : The maximum connectable units is 8. FX0N : The maximum connectable units is 4. +10V Voltage input 1) Indicates that the identified danger WILL cause physical and property damage. 5. SPECIFICATIONS • • Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage that may arise as a result of the installation or use of this equipment. All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for the actual use of the product based on these illustrative examples. Owing to the very great variety in possible application for this equipment, you must satisfy yourself as to its suitability for your specific application. 5.1 General specification Specification General specifications Same as those for the main unit Dielectric withstand voltage 500V AC, 1min (between all terminals and ground) 5.2 Performance specification and others BFM *#1 Channel 1 Channel 2 Analog circuits 24V DC ± 10%, 55mA (external power supply from the main unit) *#2 *#3 Channel 3 Digital circuits 5V DC, 30mA (internal power supply from main unit) *#4 Channel 4 #5 Channel 1 Photo-coupler isolation between analog and digital circuits. DC/DC converter isolation of power from the main unit. No isolation between analog channels. #6 Channel 2 #7 Channel 3 The analog block occupies 8 points. (can be either inputs or outputs) #8 Channel 4 The FX2N-4AD analog special function block has four input channels. The input channels receive analog signals and convert them into a digital value. This is called an A/D conversion. The FX2N-4AD has maximum resolution of 12 bits. #9 Channel 1 • The selection of voltage or current based input/output is by user wiring. Analog ranges of -10 to 10V DC (resolution: 5mV), and/or 4 to 20mA, -20 to 20mA (resolution: 20 µA) may be selected. #10 Channel 2 • The FX2N-4AD can be connected to the FX0N/FX1N/FX2N/FX2NC/FX3U series Programmable Controllers (PLC). #11 Channel 3 • Data transfer between the FX2N-4AD and the main unit is by buffer memory exchange. There are 32 buffer memories (each of 16 bits) in the FX2N-4AD. #12 Channel 4 The FX2N-4AD occupies 8 I/O points on the FX2N expansion bus. The 8 I/O points can be allocated from either inputs or outputs. The FX2N-4AD draws 30mA from the 5V rail of the main unit or powered extension unit. #13 - #14 Reserved #15 Selection of A/D conversion speed see note 2 Weight : Approx. 0.3 kg (0.66 lbs) 8 7 (3 .4 3 ) M o u n tin g h o le s 4 .5 m m ( 0 .1 8 ) d ia . 5 5 (2 .1 7 ) 4 (0 .1 6 ) 5 5 (2 .1 7 ) 2 4 - 2 4 - 2 4 + 2 4 + Contains the number of samples (1 to 4096) to be used for an averaged result. The default setting is 8- normal speed. High speed operation can be selected with a value of 1. These buffer memories contain the averaged input values for the number of samples entered for the channel in buffer memories #1 to #4 respectively. These buffer memories contain the present value currently being read by each input channel. When set to 0, a normal speed is selected of 15ms/ch (default) When set to 1, a high speed is selected of 6ms/ch #16 - #19 Reserved *#20 Reset to Defaults and Preset. Default = 0 *#21 Offset, Gain Adjust Prohibit. Default = (0, 1) Permit *#22 Offset, Gain Adjust V I- C H 1 V + V I- C H 1 V + b7 b6 b5 b4 b3 b2 b1 b0 G4 O4 G3 O3 G2 O2 G1 O1 P O W E R V II+ Default = 0 Gain Value Default = 5,000 #25 - #28 Reserved #29 Error status #30 Identification code K2010 #31 Cannot be used F G C H 3 V + I+ F G V + V I- C H 4 2 4 V L E D A /D L E D I+ 4 (0 .1 6 ) F X 2 N -4 A D V I- E x te n s io n c a b le a n d c o n n e c to r Offset Value *#24 V + C H 2 2 4 V A /D 9 (0 .3 5 ) *#23 F G 9 0 (3 .5 4 ) 8 0 (3 .1 5 ) I+ D IN r a il M o u n tin g s lo t 3 5 m m (1 .3 8 ) Dimensions : mm (inches) T e r m in a l s c r e w s M 3 ( 0 .1 2 ) Current input Contents • 2. EXTERNAL DIMENSIONS -1,600 6.1 Buffer memories Specification Number of occupied I/O points -1,000 +20mA 6. ALLOCATION OF BUFFER MEMORIES (BFM#) Channel selection Default = H0000 Item +20mA Current input *#0 Isolation 1. INTRODUCTION • 0 +4mA -20mA NOTE: Preset ranges are selected by an appropriate setting in the buffer memory of the analog block. Current/Voltage input selection must match the correct input terminal connections. Item 2) Indicates that the identified danger could POSSIBLY cause physical and property damage. +1,000 Digital output -2,000 +1,600 Digital output +1,000 -2,048 At various times throughout this manual certain symbols will be used to highlight points of information which are intended to ensure the users personal safety and protect the integrity of equipment. Preset 2 (-20mA to +20mA) +1,750 -10V Notes on the Symbols Used in this Manual • Preset 1 (+4mA to +20mA) +2,000 FX2N/FX3U : The maximum connectable units is 8. FX2NC DC -20mA to +20mA (input resistance: 250Ω). Warning: this unit may be damaged by an input currents in excess of ± 32mA. DC -10V to +10V (input resistance: 200kΩ). Warning: this unit may be damaged by an input voltage in excess of ± 15V. e If you are using current input, connect the V+ and I+ 100K: FG Current input Either voltage or current input can be selected with your choice of input terminal. Up to four input points can be used at one time. Analog input range -10.240V Guidelines for the Safety of the User and Protection of the FX2N-4AD special function block. d If a voltage ripple occurs during input, or there is 100K: 250: Item +32mA CH1 V+ 3 I+ VI- JY992D65201D This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4AD and should be read and understood before attempting to install or use the unit. Further information can be found in the FX SERIES PROGRAMMING MANUAL(ΙΙ), FX0N/FX1N/FX2N/ FX2NC/FX3U SERIES HARDWARE MANUAL. 100K: AG Voltage input shielded cable. This cable should be wired separately from power lines or any other lines which may induce electrical noise. CH4 -32mA 1 Shielded Current input -20mA to +20mA 100K: 250: +32mA CH4 V+ 2 I+ VIFG FX2N-4AD SPECIAL FUNCTION BLOCK USER’S GUIDE c The analog input is received through a twisted pair +10.235V Voltage input -10V to +10V