+00ET9X463301_01EN.book Page 24 Thursday, January 20, 2011 4:41 PM Installation Manual Air to Air Heat Exchanger 14 Troubleshooting Check codes and parts to be checked Wired remote controller display Confirmation and check When an error occurred in the Air to Air Heat Exchanger, the check code and the unit No. of Air to Air Heat Exchanger appear on the display part of the remote controller. The check code is only displayed during the operation. If the display disappears, operate the Air to Air Heat Exchanger according to the following “Confirmation of error history” for confirmation. * Unit No. of Air to Air Heat Exchanger is 31-OO. Installation Manual Air to Air Heat Exchanger E01 2 Every pushing of button used to set temperature, the error history stored in memory is displayed in order. The numbers in CODE No. indicate CODE No. [01] (latest) → [04] (oldest). REQUIREMENT Main defective parts No header remote controller Judging device Remote controller Remote controller communication error No signal can be received from the indoor unit. Remote controller transmission error Remote controller System interconnecting wires, indoor P.C. board, remote controller --- No signal can be sent to the indoor unit. E03 Indoor unit-remote controller regular communication error Indoor Remote controller, network adapter, indoor P.C. board --- No data is received from the remote controller or network adapter. E08 Duplicated indoor addresses Indoor Indoor address setting error --- The same address as the selfaddress was detected. Duplicated header remote controllers Remote controller Remote controller address setting error --- Two remote controllers are set as header in the double-remote controller control. E09 3 Check code After confirmation, push to the usual display. Incorrect remote controller setting --- The header remote controller has not been set (including two remote controllers). E02 Do not push button because all the error history of the Air to Air Heat Exchanger will be deleted. Unit No. of the Air to Air Heat Exchanger with a problem Parts to be checked / error description (* The header indoor unit stops raising alarm and follower indoor units continue to operate.) button to return E18 Header indoor unit-indoor Indoor follower unit regular communication error Indoor P.C. board --- Regular communication is not possible between header and follower indoor units or between twin header (main) and follower (sub) units. Confirmation of error history F17 Air to Air Heat Exchanger Air to Air Heat (TOA) error Exchanger Outdoor Air sensor (TOA), indoor P.C. board --- Open-circuit or short-circuit of the heat exchanger sensor (TOA) was detected. When an error occurred on the Air to Air Heat Exchanger, the error history can be confirmed with the following procedure. (The error history is stored in memory up to 4 troubles.) The error can be confirmed from both operating status and stop status. F18 Air to Air Heat Exchanger Air to Air Heat (TRA) error Exchanger Return Air sensor (TRA), indoor P.C. board --- Open-circuit or short-circuit of the heat exchanger sensor (TRA) was detected. F29 Indoor unit, other P.C. board error Indoor P.C. board --- EEPROM error L03 Duplicated header indoor Indoor units Indoor address setting error --- There are two or more header units in the group. L08 Indoor group address not Indoor set Indoor address setting error --- Indoor address group has not been set. 2 L09 L20 P31 1 3 Indoor Indoor power level not set Indoor Indoor power level has not been set. LAN communication error Indoor Address setting, central control remote controller, network adapter --- Duplication of address in central control communication Other indoor unit error Another indoor unit in the group is raising an alarm. Indoor E03/L07/L03/L08 alarm check locations and error description * “Indoor” in “Judging device” refers to the Air to Air Heat Exchanger or the air conditioner. 1 When pushing and buttons at the same time for 4 seconds or more, the following display appears. If [Service check] is displayed, the mode enters in the trouble history mode. • [01: Order of error history] is displayed in CODE No. window. • [Check code] is displayed in CHECK window. • [Air to Air Heat Exchanger address in which an error occurred] is displayed in Unit No. * Unit No. of Air to Air Heat Exchanger is 31-OO. EN 47-EN – 24 – 48-EN