Terminal Definitions and Descriptions
193
Terminal
Definition
N/O
COMM
N/C
These relay contacts are fully programmable as with Outputs 1, 2 and 3. They are factory defaulted as an
alarm output (Sirens Running - Event Type 1,15).
The N/O contact is the connection point for the positive side of a DC siren such as a piezo screamer. The
negative side of the DC siren needs to be connected to the GND terminal. A link (JP7) is provided on the
PCB for connecting the COM terminal to either GND or 12V. This link should be connected to +12V as
shown in "Figure 13: Solution-16 Wiring Diagram" on page 194. The relay is rated at 1 Amp/30 VDC.
+12V
GND
These two terminals are provided to power detectors and other equipment. They are fuse protected by the 1
amp fuse.
+12V
Z1
Z2
Z3
Z4
These terminals are zones one to four and their common terminal is +12V. All normally closed contacts are
to be connected in series with the EOL resistor, where all normally open contacts are to be connected in
parallel with the EOL resistor. The function of the zones and their response times are programmable via the
system programming options.
+12V
GND
These two terminals are provided to power detectors and other equipment. They are fuse protected by the 1
amp fuse.
Z5
Z6
Z7
Z8
+12V
These terminals are zones five to eight and their common terminal is +12V. All normally closed contacts
are to be connected in series with the EOL resistor, where all normally open contacts are to be connected in
parallel with the EOL resistor. The function of the zones and their response times are programmable via the
system programming options.
+12V
GND
These two terminals are provided to power detectors and other equipment. They are fuse protected by the 1
amp fuse.