Transcript
Installation Manual Air to Air Heat Exchanger with DX Coil Unit Air to Air Heat Exchanger with DX Coil Unit Heat insulation Flaring dia. meter size: A (Unit: mm) A +0 –0.4 Outer dia. of copper pipe R410A 6.4 9.1 9.5 13.2 12.7 16.6 Installation Manual * In case of flaring for R410A with the conventional flare tool, pull it out approx. 0.5 mm more than that for R22 to adjust to the specified flare size. The copper pipe gauge is useful for adjusting projection margin size. Apply heat insulation for the pipes separately at liquid side and gas side. • For the heat insulation to the pipes at gas side, be sure to use the material with heat-resisting temperature 248 °F (120 °C) or higher. • Using the attached heat insulation material, apply the thermal insulation to the pipe connecting section of the indoor unit securely without gap. A REQUIREMENT • The pressure of gas in the unit is the same as the atmospheric pressure. Therefore, no air leaking sound comes out when the flare nut is loosened. This is not anything unusual. • Use 2 wrenches to perform piping of indoor units. • Apply the heat insulation to the pipe connecting section of the indoor unit securely up to the root without exposure of the pipe. (The pipe exposed to the outside causes water leak.) • Wrap heat insulator with its slits facing up (ceiling side). Wrap the pipe with the attached heat insulator without any gap between the indoor unit. Indoor unit The seam must be faced upward (ceiling side). Using 2 wrenches • Refer to the table below for tightening torque. Outer diameter of connecting pipe (mm) Tightening torque (N•m) Ø6.4 14 to 18 (1.4 to 1.8kgf•m) Ø9.5 33 to 42 (3.3 to 4.2kgf•m) Ø12.7 50 to 62 (5.0 to 6.2kgf•m) Heat insulation pipe (Accessory) • Tightening torque of flare pipe connections Pressure of R410A is higher than that of R22. (Approx. 1.6 times) Therefore, using a torque wrench, tighten the flare pipe connecting sections which connect the indoor and outdoor units of the specified tightening torque. Incorrect connections may cause not only a gas leak, but also a trouble of the refrigeration cycle. Flare nut Union Heat insulator of the pipe REQUIREMENT Tightening with an excessive torque may crack the nut depending on installation conditions. Tighten the nut within the specified tightening torque. Leak check test and vacuuming Refer to the Installation Manual of the outdoor unit for leak check test, vacuuming, adding a refrigerant, or checking gas leakage. REQUIREMENT Do not turn on the indoor unit before leak check test and vacuuming are finished; otherwise, the electric expansion valve is closed fully and vacuuming from the liquid or gas side is not performed properly. If the indoor unit should be turned on, perform vacuuming from both the liquid side and the gas side. Opening the valve fully Open the valves of the designated outdoor unit fully. EN 19-EN – 10 – 20-EN