Download ADN2850 Evaluation Kit User Manual Application

Transcript
AN-628
section). Other op amps in PDIP can replace the AD820. For a
single-supply, 2.5 V voltage reference, AD1582 can be
used to offset the op amp bias point for ac operation.
EVALUATION BOARD SCHEMATIC
The general-purpose op amp AD820, U3A can be configured
as various building block circuits in conjunction with the
ADN2850 for various circuit evaluations (see the Applications
ADN2850 MAIN CIRCUIT
+5
+5V
(LOWER TO +2.5V IF DUAL SUPPLIES)
R2
10k
R3
10k
C10
4.7F
R4
10k
C11
0.1F
DGND
J1
13
25
12
24
11
23
10
22
9
21
8
20
7
19
6
18
5
17
4
16
3
15
2
14
1
U1A
ADN2850CSP 16
15
14
13
TPSDO
SDI CLK RDY CS
1
+5
TPCLK
S1
LOW
1
8
2
7
3
6
4
5
SW-DIP4
W1 B1 B2 W2
R1
1k
TPSDI
12
PR
11
WP
10
VDD
9
A2
SDO
2
GND
3
VSS
4
A1
TP/CS
TPRDY TP/PR TP/WP
HIGH
5
6
7
8
A1
W1
B1
R_CS 100
R_CLK 100
1
R_SDI 100
CLK
SDI
SDO
GND
VSS
A1
W1
B1
2
3
4
5
DB25
6
7
8
NOTES
SIGNAL GROUND WITH NET DGND
POWER GROUND WITH NET AGND
16
RDY
CS
PR
WP
VDD
A2
W2
B2
15
A2
14
13
12
W2
11
10
9
B2
U1B
ADN2850TSSOP
JP14
GND
HEADER
C12
0.1F
JP15
C13
4.7F
–5V
HEADER
–5
(LOWER TO –2.5V IF DUAL SUPPLIES)
ADDITIONAL OP AMP FOR GENERAL-PURPOSE APPLICATIONS
V+
V–
VO
JP7
JP9
JP5
HEADER
JP6
JP8
C5
0.1F
+5
JP4
HEADER
2
JP2
HEADER
VI_DC
7
1, 5, 8
–
U3A
AD820AR
6
VO
3
+
4
JP3
HEADER
C9
JP10
JP11
JP1
VI_AC
U2
AD1582
GND
+5
3
C7
0.1F
JP12
HEADER
2
VIN
1
VOUT
2.5 VREF
JP13
HEADER
C6
–5 0.1F
C8
0.1F
+5
2
7
U3B
AD820AN
3 +
1
8
–
4
6
5
REPLACEABLE
OP AMP IN PDIP
Figure 3. Evaluation Board Schematic
–6–
REV. 0