Download USER MANUAL FOR EXPLOSION PROTECTED
Transcript
3. PURPOSE Explosion proof pendant lighting fitting, type PLFL -./… is intended for general lighting in industrial with potentially explosive atmosphere, in Zones 1, 2 and in areas endangered by explosive and flammable mixtures of dust and air in Zones 21, 22 accordance with EN 60079-10-1/-2: 2009. 4. PRODUCT COMPLIANCE Design of lighting fitting is accordance with the standard EN 60598-1:2008 and all related standards. The product is in compliance with Regulations concerning equipment and protective systems for use in potentially explosive atmosphere. The product complies with the ATEX Directive 94/9 EC and standards: - EN 60079-0:2012, - EN 60079-1:2007, - EN 60079-7:2007, - EN 60079-31:2009. The product has been developed, manufactured and tested according to the existing state of technique accordance with the standards EN 9001:2008 and EN ISO / IEC 80079-34:2011. The product is in compliance with the LV Directive 2006/95 EC. The product is in compliance with the RoHS Directive 2011/65 EU. The product is in compliance with EMC Directive 2004/108 EC. 5. DEGREE OF PROTECTION AND DATA Certificate Category and explosion protection: EXA 14 ATEX 0001 II 2G Ex d e IIC T4-T3 Gb or II 2G Ex d IIC T4-T3 Gb II 2D Ex tb IIIC T140°C - T150°C Db Ambient temperature: Thermal stability of cable at Ta> +40°C and direct entry: Service temperature of cable gland at Ta> +40°C: Mechanical protection: Resistance to shock: Class of protection: Rated voltage: Frequency: Rated power: -20ºC ≤ Ta ≤ +40ºC or +50ºC Rated current: Power factor Entries: Ex d adapter: Connection terminals inside adapter, type PLFL-1/... Connection terminals inside light fitting External PA / PE terminal: Tightening torque: Wiring: Lamp holder: Locking switch: ≥ 90°C ≥ 90°C IP66, category 1 IK 08 I (PE - protective earthing) -230 V (-10% / +6%) -50 Hz - see selection table -A 500 W 2,30 A - IQ 500 W 2,10 A - LME 250 W 1,30 A - HIE 250 W 1,80 A - HSE 250 W 1,80 A - HME 250 W 1,80 A - cos ϕ > 0,9 discharge lamps - cos ϕ = 1 lamps - two entries Ex d, M20x1,5-6H in accordance EN 60079-1:2007, ISO 965-1, ISO 965-3 - type ADP 23/1, II 2G Ex d e IIC Gb II 2D Ex tb IIIC Db, cable gland ISO 25 for cable v 7-15 mm - terminals for connection L + NE + PE; 2,5 mm2, - solid, stranded - terminals for connection L + NE + PE; 2,5 mm2, solid, stranded - it is possible through wiring, Imax= 16 A - max 2 x 6 mm2 flexible, 3 pcs. - housing of Ex d e adapter and Ex d plug 3,5 Nm - pressure nut of cable gland 2,5 Nm - screws of Ex e terminal 1,2 Nm - Radox 155, 1,5 mm2, 1 kV AC, -55 ºC do +155 ºC, in accordance EN 60228:2005 class 5, mark of quality VDE - E 40, 750 V, 4A, 5 kV, in accordance EN 60238:2004; mark of quality ENEC - two-pole, 250 V, 16(4) A, -40 ºC do +150 ºC, 2