Download General Installation Manual
Transcript
General Installation Manual not be frequently observed in actual • practice. To avoid the hazard of electric shock and sparks, please connect each cable after confirming the polarity of them is correct. Application class of product SANYO HIT PV-modules are applied to application class A. Application class A for PV-modules are defined as follows: Class A: General access, hazardous voltage, hazardous power applications Module rated for use in this application class may be used in systems operating at greater than 50 V DC or 240 W, where general contact access is anticipated. Modules qualified for safety through this part of IEC 61730-1 and IEC 61730-2 and within this application class are considered to meet the requirements for safety class II. • Module Wiring • The maximum number of NKHE-type modules that can be wired in series is seventeen (17). • Modules shall not be wired in parallel without maximum over current protection. • SANYO solar modules are not designed for “off-grid” or battery charging systems, because of their operating voltage. Therefore, it is not recommended to use them to charge batteries. • These modules contain factory installed bypass diodes. If these Fire class of product modules are connected each other Sanyo HIT PV modules fill the fire class C incorrectly, the bypass diodes, cable, that provides to ANSI/UL790. Class C roof or junction box may be damaged. coverings are effective against light fire test exposures. Under such exposures, Array Wiring roof coverings of this class afford a light • The term “array” is used to describe degree of fire protection to the roof deck, the assembly of several modules on a do not slip from position, and are not support structure with associated expected to produce flying brands. wiring. • Use copper wire that is sunlight Mechanical Loading resistant and is insulated to withstand • The modules should be mounted the maximum possible system open basically at the four (4) quarter points circuit voltage. by the means shown in Figure 2-1. • Check your local codes for However, you may choose the requirements. optional mounting ranges (with limitation of fixing span) by means Earth Ground Wiring shown in Figure 2-2 or Figure 2-3. • The kind of the earth construction • This method offers a maximum load shall conform to IEC61730-1. of 2400N/m2 (50PSF, in a static • Bonding shall be by a positive means, state) on the module surface. such as clamping, riveting, bolted or screwed connections, or welding, CERTIFICATION soldering or brazing. The bonding The HIP-xxxNKHE5, xxxNKHE5-2 connections shall penetrate all nonModules comply with the requirements of conductive coatings, such as paint, IEC61215, IEC61730-1, IEC61730-2 and anodized coatings or vitreous enamel. the CE mark. • A wiring terminal or bonding location of module intended to accommodate WIRING a field installed equipment-grounding General conductor shall be identified with the • All wiring should be done in appropriate symbol (IEC 60417accordance with applicable electrical 5019(DB: 2002-10)) or shall have a codes. green-colored part. • All wiring should be done by a • Grounding should be carried out by qualified, licensed professional. the attachment to the module or array • Wiring should be protected to help frame, to avoid the hazards of electric ensure personal safety and to prevent shock or fire. its damage. • All modules connected in series Module Terminations should be of the same model number • A junction box as a terminal and/or type. enclosure is equipped for electrical • Do not connect modules in parallel connections on SANYO modules. TM without using a connection box. • Modules are equipped with MC • Do not disconnect terminals while PV plugs as a terminal enclosure. Use TM modules generate electricity and plugs for electrical these MC connect electrical load to avoid the connections. hazard of electrical shock. • If two or more separable connectors are provided, they shall be configured 3 or arranged so that the other and vice-versa will not accept the mating connector for one, if it will result in an improper connection. Please contact your SANYO Authorized Representative with questions regarding other electrical connections if needed. Junction Box and Terminals • Modules equipped with one junction box contain terminals for both positive and negative polarity, and bypass diodes. • One terminal is dedicated to each polarity (with the polarity symbols engraved onto the body of the junction box) (see Figure 3). Conduit • For applications where wire conduits are used, follow the applicable codes for outdoor installation of wires in conduits. Minimum diameter of wire 2 conduit is 2.5 mm . • Verify that all fittings are properly installed to protect wires against damage and prevent moisture intrusion. DIODES Bypass Diodes • When the modules in series strings are shaded partially, it may cause reverse voltage across cells or modules, because the current from other cells in the same series is forced to flow through the shaded area. This may cause undesirable heating to occur. • The use of a diode to bypass the shaded area can minimize both heating and array current reduction. • All SANYO modules are equipped with factory installed bypass diodes. The factory installed diodes provide proper circuit protection for the systems within the specified system voltage, so that you do not need any other additional bypass diodes. • Contact your SANYO Authorized Representative for proper diode type, if it is necessary to add or change diodes due to system specifications. MAINTENANCE • Some maintenance is recommended to maintain optimal output performance of the solar modules. • If the module surface becomes dirty, it may reduce output power. • It is recommended to clean the surface of the module with water and a soft cloth or sponge. • A mild non-abrasive detergent may be applied for persistent dirt.