Download User manUal
Transcript
6.Specifications Central Unit Power supply Power consumption Wireless connection Pollution degree Extinguisher Unit 230 V ∼ 1 N, 47–60 Hz Output voltage of the power source 5 V 1 A 1W Compatibility SAFERA RobustLink 2,4 GHz. Range 10–100 m, depending on the building structure 2 Power supply Power consumption Control type Pollution degree Impulse voltage rating Operational ambient temperature Ball pressure test rating PTI of insulation materials Designed number of automatic actuations IP class Power consumption Fire extinguishing agent Dimensions 0 W, in an extinguishing situation 5 W 0,4 l Fettex, a class F fire extinguishing agent 70 x 70 x 350 mm Service cycle 5 years The fire ex- 10 years tinguishing agent’s service life Power Control Unit Compatibility Power supply Typical cooktop fires, including grease fires 5V Most electric cookers and hobs used in private homes. See specific compatibility on the label of the power control unit Ⓒ. 230 V ∼ 3 N, 50 Hz or 230 V ∼ 1 N, 50 Hz 2W 7.Warranty The appliance comes with a 24 month warranty as regulated in the general warranty terms of SAFERA. According to IEC/EN 60730 - 1 : Type 1.B 2 4 kV +5 … +40 °C 100 °C 175...400 6000 See power control unit 11