Download SERVICE MANUAL/INTEGRATION SPLIT TYPE
Transcript
Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy RAV-SM1100/1400UT-E RAV-SM1100/1400AT-E 10-4-4. Check Code Table RAV-SM1100UT-E, RAV-SM1400UT-E, RAV-SM1100AT-E, RAV-SM1400AT-E (A03-003) Error mode detected by indoor unit (1) Operation of diagnostic function Block display Check code [MODE] [TIMER] lamp 5Hz flash Cause of operation Status of air conditioner The serial signal is not output Operation from outdoor unit to indoor unit. continues Judgment and measures Condition Displayed when 1. Outdoor unit does not completely error is detected operate. • Miscabling of inter-unit cables • Inter-unit cable check, correction of miscabling • Defective serial sending circuit on outdoor P.C. board • Outdoor P.C. board check, P.C. board cables check • Defective serial receiving circuit on outdoor P.C. board • Compressor case thermo check • Compressor case thermo operation 2. In normal operation When outdoor sending serial LED (Green) flashes, the receiving serial LED (Orange) also flashes. : Indoor P.C. board (Main P.C. board) check When the receiving serial LED (Orange) does not flash: Outdoor P.C. board check BUS communication circuit error Operation Displayed when 1. Communication line check, miscabling continues error is detected check * BUS communication was Power supply check for central interrupted over the specified (According to remote controller (Central control remote time. controller of controller, etc.) and indoor unit indoor unit) 2. Communication check (XY terminal) 3. Indoor P.C. board check 4. Central controller check (Communication P.C. board) Network address miss-setting • Addresses of central controllers (Central control remote controller, etc.) are duplicated. Operation continues Displayed when 1. Check central control system network error is detected address setting. (SW02) 2. Indoor P.C. board check 3. Central controller check (Communication P.C. board) Error in 4-way valve system Operation continues • Indoor heat exchanger temperature rise after start of cooling operation. Displayed when 1. Check 4-way valve. error is detected 2. Check 2-way valve and non-return valve. 3. Check indoor heat exchanger sensor (TC). • Indoor heat exchanger temperature fall after start of heating operation. Error in other cycles • Indoor heat exchanger temp (TC) does not vary after start of cooling/heating operation. 4. Check indoor P.C. board (Main P.C. board). Operation continues Displayed when 1. Compressor case thermo operation error is detected 2. Coming-off of detection part of indoor heat exchanger sensor 3. Check indoor heat exchanger sensor (TC). * 4. Check indoor P.C. board (Main P.C. board). [MODE] lamp 5Hz flash Coming-off, disconnection or short of indoor temp sensor (TA) Operation continues Displayed when 1. Check indoor temp sensor (TA). error is detected 2. Check indoor P.C. board (Main P.C. board). Coming-off, disconnection or short of indoor temp sensor (TC) Operation continues Displayed when 1. Check indoor temp sensor (TC). error is detected 2. Check indoor P.C. board (Main P.C. board). Coming-off, disconnection or short of indoor temp sensor (TCJ) Operation continues Displayed when 1. Check indoor temp sensor (TCJ). error is detected 2. Check indoor P.C. board (Main P.C. board). * : No display in the setting at shipment – 143 – www.ilmalämpöpumput.com