4 Mounting 4.6 Differential pressure measurement In gases and vapours à Mount VEGADIF 65 above the measurement loop so that condensate can drain off in the process cable. 1 2 + 3 3 4 Fig. 22: Measurement setup, differential pressure measurement in gases and vapours 1 2 3 4 In liquids VEGADIF 65 Three-fold valve block Blocking valves E.g. filter à Mount VEGADIF 65 below the measurement loop so that the effective pressure lines are always filled with liquid and gas bubbles can bubble up to the process line à For measurements in products with solid content such as e.g. dirty liquids, the installation of separators and drain valves is recommended to enable collection and removal of debris and sediment. 36128-EN-091126 26 VEGADIF 65 • 4 … 20 mA/HART