Download User's Guide to AutoProbe CP - Advanced Processors Technologies
Transcript
viii Chapter 5 I-V Spectroscopy .........................................................5-1 Introduction..................................................................................................................... 5-2 The I-V Spectroscopy Window....................................................................................... 5-3 I-V Spectroscopy Controls.............................................................................................. 5-5 Acquiring Current vs. Voltage Data................................................................................ 5-7 Generating a Current vs. Voltage Curve........................................................... 5-7 Generating an I-V Curve at a Different X, Y Location .................................... 5-9 Adjusting the Horizontal and Vertical Scales of an I-V Curve......................... 5-9 Zooming in on a Region of Interest ................................................................ 5-11 Zooming in Graphically Using the Cursor ....................................... 5-11 Zooming in by Changing the Voltage Sweep Range........................ 5-11 Making Point-to-Point Measurements on an I-V Curve ................................. 5-12 Saving and Exporting Data............................................................................. 5-12 Redisplaying Curves in I-V Spectroscopy...................................................... 5-13 Summary....................................................................................................................... 5-14 Chapter 6 Scanner Calibration....................................................6-1 Introduction..................................................................................................................... 6-2 How the Scanner Works ................................................................................................. 6-3 When to Calibrate the Scanner........................................................................................ 6-4 Calibrating a 5 Micron Scanner ...................................................................................... 6-5 What it Means to Calibrate a 5 Micron Scanner............................................... 6-5 Scanner Calibration Procedures........................................................................ 6-6 Setting Up the System ........................................................................ 6-7 First-Order Calibration of Scanner Sensitivity in X and Y .............. 6-11 Second-Order Calibration of Scanner Sensitivity in X and Y .......... 6-17 Calibration of Scanner Sensitivity in Z ............................................ 6-20 Creating a Backup Scanner Calibration File .................................... 6-23 Calibrating a 100 Micron Scanner ................................................................................ 6-24 How ScanMaster Works ................................................................................. 6-24 What it Means to Calibrate a 100 Micron Scanner......................................... 6-26 Scanner Calibration Procedures...................................................................... 6-27 Installing the System Hardware........................................................ 6-27 Configuring the System Software .................................................... 6-28 Calibrating the XY Detector............................................................. 6-31 Calibrating the Z Detector ................................................................ 6-34 Auto Calibration of Detector Offsets and Scanner Sensitivity ......... 6-36 Creating a Backup Scanner Calibration File .................................... 6-38 Summary....................................................................................................................... 6-40