Pumped Electric Shower
Installation and User Guide
These instructions are to be left with the user
Contents
Introduction................................................................................................. 3
Important Safety Information...................................................................... 4
Pack Contents Checklist............................................................................ 6
1. Mira Elite ST...................................................................................... 6
2. Documentation.................................................................................. 6
3. Mira Logic Electric Shower Fittings................................................... 7
Specifications............................................................................................. 8
1. Plumbing........................................................................................... 8
2. Electrical............................................................................................ 8
3. Standards and Approvals.................................................................. 8
Installation Requirements........................................................................... 9
1. Plumbing........................................................................................... 9
2.1 Electrical........................................................................................ 13
2.2 Electrical (checklist in detail)......................................................... 14
Installation................................................................................................ 15
Mira Elite ST........................................................................................ 15
Mira Logic Electric Shower Fittings..................................................... 17
Commissioning......................................................................................... 19
User Instructions...................................................................................... 21
Using Your Shower.............................................................................. 22
Fault Diagnosis......................................................................................... 24
Maintenance............................................................................................. 27
Handset - Cleaning.............................................................................. 27
Filter - Cleaning/Renewing.................................................................. 27
Dimensions............................................................................................... 28
Wiring Diagram......................................................................................... 29
Spare Parts.............................................................................................. 30
Mira Elite ST Spare Parts List............................................................. 30
Mira Logic Electric Shower Fittings Spare Parts List........................... 32
Optional Accessories................................................................................ 33
Notes........................................................................................................ 34
Customer Service........................................................................Back Page
Introduction
Thank you for purchasing a quality Mira product. To exploit the full potential of your
new product, please take time to read this guide thoroughly. Having done so, keep
it handy for future reference.
The Mira Elite ST is a tank-fed (cistern-fed) pumped electric shower for use where
the mains water supply pressure is too low, unreliable or non existent, to operate a
conventional electric shower.
The Mira Elite ST features an internal pump unit which has been designed to provide
all year round performance, even at the highest flow rates which are necessary
during the summer months. The Elite ST has separate controls for power selection
and temperature/flow adjustment. The Elite ST must have its own separate cold
water supply from the cistern to ensure correct operation.
The Mira Elite ST comes complete with a set of Mira Logic Electric Shower
Fittings.
Products Covered By This Guide:
Mira Elite ST - A 9.8 kW @ 240 Volts AC (9.0 kW @ 230 Volts AC) heater. Available
in white/chrome finish.
Mira Logic Electric Shower Fittings
An adjustable spray handset with four different spray actions (start, soothe, force
and eco), supplied complete with flexible hose, clamp bracket assembly, slide bar,
supports, soap dish/hose retaining ring. Available in white/chrome finish.
If you experience any difficulty with the installation or operation of your new
shower control, then please refer to "Fault Diagnosis", before contacting Kohler
Mira Limited. Our telephone and fax numbers can be found on the back cover
of this guide.
Important Safety Information
1. Warning!
1.1 Products manufactured by us are safe and without risk provided they are
installed, used and maintained in good working order in accordance with our
instructions and recommendations.
1.2 This Appliance must be earthed. MAKE SURE SUPPLEMENTARY
BONDING COMPLIES WITH THE "REQUIREMENTS FOR ELECTRICAL
INSTALLATIONS".
In accordance with the current edition of BS 7671 ‘The IEE Wiring Regulations'
in force at the time of installation. This appliance is intended to be permanently
connected to the fixed electrical wiring of the mains system with its own dedicated
supply.
1.3 DO NOT twist the individual cable cores of the live and neutral conductors, as
this will prevent them from entering the terminal block.
1.4The shower unit must NOT be fitted where it may be exposed to freezing
conditions. Make sure that any pipework that could become frozen is properly
insulated.
1.5 DO NOT operate this appliance if it appears to be frozen. Allow the appliance
to thaw and then contact your installer before using again.
1.6There are no user serviceable components beneath the cover of this appliance.
Only a competent tradesperson should remove the cover. If the cover is removed,
the following warnings must be observed:
1.6.1Turn off the electrical and water supplies before removing the cover.
1.6.2Mains connections are exposed when the cover is removed.
1.6.3Refer to the wiring diagram before making any electrical connections
(see section "Wiring Diagram").
1.6.4Make sure all electrical connections are tight, to prevent them
overheating.
1.7 If any of the following conditions occur, isolate the electricity and water supplies.
Contact your installer or refer to “To contact us”, on the back page of this
guide:
1.7.1 If water is leaking from inside the product.
1.7.2 If the case is damaged.
1.7.3 If the appliance begins to make an odd noise, smell or smoke.
1.7.4 If the appliance shows signs of a distinct change in performance,
indicating a need for maintenance.
1.7.5 If the cover is not correctly fitted.
1.8 DO NOT fit any form of outlet flow control as the outlet acts as a vent for the
tank body. Only Mira recommended outlet fittings should be used.
2. Caution!
2.1Read all of these instructions and retain this guide for later use.
2.2 Pass on this guide in the event of change of ownership of the installation site.
2.3 Follow all warnings, cautions and instructions contained in this guide, and on
or inside the appliance.
2.4The electrical installation must comply with the “Requirements for Electrical
Installations” (see section "Installation Requirements") commonly referred
to as BS 7671 the IEE Wiring Regulations, or any particular regulations and
practices, specified by the local electricity supply company in force at the time of
installation. The installation should be carried out by an electrician or contractor
who is registered, or is a member of, an association such as:
2.4.1 National Inspection Council for Electrical Installation and Contracting
(NICEIC), throughout the UK.
2.4.2The Electrical Contractors Association (ECA), England and Wales.
2.4.3The Electrical Contractors Association of Scotland (ECAS).
2.5The plumbing installation must comply with the requirements of UK Water
Regulations/Bye-laws (Scotland), Building Regulations or any particular
regulations and practices, specified by the local water company. The installation
should be carried out by a plumber or contractor who is registered, or is a
member of, an association such as:
2.5.1 Institute of Plumbing (IOP), throughout the UK.
2.5.2 National Association of Plumbing, Heating and Mechanical Services
Contractors (NAPH & MSC), England and Wales.
2.5.3 Scottish and Northern Ireland Plumbing Employers’ Federation (SNIPEF),
Scotland and Northern Ireland.
2.6 Anyone who may have difficulty understanding or operating the controls of any
shower should be attended whilst showering. Particular consideration should
be given to the young, the elderly, the infirm, or anyone inexperienced in the
correct operation of the controls.
2.7When this appliance has reached the end of its serviceable life, it should be
disposed of in a safe manner, in accordance with current local authority recycling,
or waste disposal policy.
Pack Contents Checklist
 Tick the appropriate boxes to familiarize yourself with the part names and to

confirm that the parts are included.
1. Mira Elite ST
1 x Case Insert
3 x Rubber Feet
1 x Olive
1 x Compression Nut
3 x Fixing Screws
3 x Wall Plugs
1 x Mira Elite ST
2. Mira Logic Electric Shower Fittings
2 x Wall Plugs
2 x Fixing Screws
2 x Slide Bar End Caps
2 x Slide Bar End Supports
1 x Applicator
1 x Handset
1 x Slide Bar
2 x Hose Seals
1 x Clamp Bracket Assembly
1 x 1.25 m Flexible Hose
1 x Soap Dish/Hose Retaining Ring
1 x Soap Dish Collar
3. Documentation
1 x Installation and User Guide
1 x Installer Checklist
1 x Guarantee Card
1 x Template (Use inner fitment)
Specifications
1. Plumbing
1.1 The 15 mm inlet compression connector incorporates an inlet filter. The inlet
swivels to allow top, bottom or rear entry.
1.2The outlet terminates with a 1/2" BSP male thread for connection to a Mira
flexible shower hose.
2. Electrical
This is a high power unit, it is essential to contact your electricity supply company
to make sure that the electricity supply is adequate for the purpose.
2.1The terminal block will not accept cable larger than 16 mm2.
2.2 The motor is fitted with a self resetting thermal trip protection device, designed
to operate if the ambient temperatures become too high. The maximum
recommended ambient temperature for the Elite ST is 30°C.
2.3The following power ratings for the heater tanks are available with their respective
voltages: Mira Elite ST 9.8 kW @ 240 V / 45 Amps (9.0 kW @ 230 V / 40
Amps).
2.4The motor will absorb approximately 100 Watts maximum power under normal
working conditions.
3. Standards and Approvals
3.1The Mira Elite ST has been designed to comply with the requirements of the
British Electrotechnical Approvals Board (BEAB) and the requirements of UK
Water Regulations/Bye-laws (Scotland).
3.2This Mira Elite ST complies with all relevant directives for CE marking.
Installation Requirements
1. Plumbing
Read the section 'Important Safety Information' first.
1.1The Elite ST is designed to operate with water supply pressures from 0.8 kPa
(0.008 bar / 80 millimetres head) to 100 kPa (1 bar / 10 metres head) (i.e. the
vertical distance from the base of the cold cistern to the top of the Elite ST).
However, the minimum head required will increase with pipe length and the
guide given in paragraph 1.17 should be used to make sure that adequate head
is available for any given installation.
The Elite ST MUST have its own separate supply from the cistern.
25 Gallon/113 Ltr Cistern
Correct Cistern Take Off
25 mm
Positioned away from the ball
valve, with a 25 mm distance
up from the base of the
cistern. This connection will
prevent air and debris entering
the shower supply.
Incorrect Cistern Take Off
Debris from the bottom of the
cistern and air generated when
the cistern refills will enter the
shower supply.
1.2 The Elite ST is suitable for installation within the shower area and is fitted with
a pressure relief valve. It must be positioned over a water catchment area with
the controls at a convenient height. The shower fitting should be positioned so
that it discharges down the centre line of the bath, or across the opening of a
shower cubicle, and must be directed away from the shower unit.
1.3 Use a minimum of 15 mm diameter supply pipework. It should be noted, however,
that on long pipe runs this should be increased to 22 mm (refer to para 1.17 for
guidance). When using flexible plastic pipe it is essential that the pipe is kept
flat and not looped up at any point as this may lead to air build up which may
impair performance of the shower.
1.4 A non restrictive (free flowing) isolating valve should be fitted into the supply
from the cold water cistern, for maintenance purposes.
1.5 The Elite ST must be fitted onto the finished wall surface i.e. on top of the
tiles. Do not block the air ventilation gaps around the sides of the unit, either
by tiling up to the sides of the unit or by using a sealant around the case.
Important! This Elite ST is designed to be ventilated. Failure to do this may
cause product failure.
Note! The Mira Elite ST is fitted with a pump motor, and some mechanical
noise can be expected in addition to the noise generated by the spray from
the handset. The type of wall surface will affect the perceived sound levels.
Stud partition and panel walls have a tendency to resonate, whilst solid walls
provide the quietest operation. The tone of the pump motor may change when
the temperature control knob is adjusted. This is quite normal.
1.6 Inlet: 15 mm inlet compression connector is designed to accept plumbing supplies
from the top, bottom or rear.
1.7Rear entry plumbing is accommodated without the need to recess the 15 mm
inlet compression connector, enabling the wall’s surface to be completed and
sealed to prevent water ingress, before final fitting.
1.8 Swivel the inlet connector assembly to suit (not directly back into the wall). Avoid
trapping the green earth bonding wire.
1.9 Use only the 15 mm inlet compression connector supplied with the Elite ST, do
not use any other types of fitting.
1.10Outlet: 1/2" BSP male, to accept Mira flexible hose.
1.11Refrain from applying excessive force when making connections.
Note! Excessive force on the pump housing can impair pumping performance.
Make sure that the supply pipe is trimmed and bent such that the 15 mm inlet
connector sits (or can be lightly pressed) easily on the back of the clamp bracket
prior to connection with the pump housing.
1.12To avoid damage to the case when soldered fittings are used, pre-solder the
pipework and fittings before connecting them to the 15 mm inlet compression
connector.
1.13Supply pipework MUST be flushed to clear debris before connecting the
Elite ST.
10
1.14A hose retaining ring is supplied to prevent the handset from dropping below
the spillover level of the bath or shower, which could lead to contamination
from back-siphonage (refer to illustration). The supplied hose retaining ring
should meet the great majority of user requirements for shower installations
with flexible outlet fittings. However, there will be occasions when the hose
retaining ring will not provide a suitable solution. In these instances an outlet
double checkvalve, e.g. the Mira DCV-H, must be fitted. The inclusion of the
Mira DCV-H will increase the required supply pressure typically by 10 kPa (0.1
bar).
Double checkvalves, fitted in the inlet supply to the appliance, cause a
pressure build-up, which could exceed the maximum static inlet pressure for
the appliance.
1.15When installed in very hard water
areas (above 200 ppm temporary
hardness) your installer may advise
the installation of a water treatment
device, to reduce the effects of
limescale formation. Your local water
company will be able to advise the
hardness of water in your area.
1.16Avoid layouts where the hose will be
sharply kinked. This may reduce the
life of the hose.
Soap Dish/Hose
Retaining Ring
25 mm Minimum
Spill-over
Level
1.17Long pipe runs and excessive use of 90° elbows will significantly reduce the
available head to supply the Elite ST. The pipework table should be completed
to ensure that adequate head is available for any given application.
11
Pipework
The dimension (x) is calculated from the table below to give you a minimum
effective head of 80 mm which is necessary to produce a satisfactory shower in all
conditions.
Plumbing Schematic Diagram
A
B
X
Example!The example below is based on the diagram above with 15 mm pipework, A = 1.5 m, B = 0.75 m.
Head Loss (mm)
Quantity
Size
15 mm Pipe
(A)
22 mm Pipe
(A)
1.5
+ (B)
0.75
+ (B)
=
2.25
=
15 mm Elbow
Number of Elbows
22 mm Elbow
Number of Elbows
x 120
270
x 20
1
x 55
55
x 15
Minimum Effective Head
80
(x) mm
405
12
2.1 Electrical
Read the section 'Important Safety Information' first.
Checklist
2.1.1 Electrical supply fuse and consumer unit are adequate for the product.
2.1.2 Shower unit is earthed.
2.1.3 The minimum required supply cable size must conform to BS 7671.
2.1.4 Double pole isolating switch.
2.1.5 Do not twist live or neutral cable cores.
2.1.6 Electrical connections are tightly secured.
Do not strain terminal block.
2.1.7 Plumbing supply completed before electrical supply is turned on.
Plumbing and Electrical Schematic Diagram
Cold Water Storage
Cistern (Tank)
Cold Water
Mains Feed
Warning Pipe
Hot Water
Cylinder Vent
Pipe
Independent Cold Water Supply
to Shower
Isolating
Valve
Consumer Unit
Cistern Fed
Cold Supply
to Other
Outlets
Soap Dish/
Hose Retaining
Ring
Hot Water
Cylinder
Feed
13
Double Pole
Isolating Switch
2.2Electrical (checklist in detail)
2.2.1 In a domestic installation, the rating of the electricity supplier's fuse and
the consumer unit must be adequate for the additional demand. The
Mira Elite ST is a high power unit, therefore it is essential to contact
your electricity supplier to ensure that the supply is adequate for the
product. Voltage drop due to local heavy demand will reduce the shower's
performance.
2.2.2 The Mira Elite ST must be earthed by connecting the supply-cable
earth conductor to the earth terminal.
Supplementary bonding: Within the bathroom or shower room, all
accessible conductive parts of electrical equipment and extraneous
conductive parts (metal parts) that are likely to introduce earth
potential, must be electrically bonded to earth using a minimum cable
size of 4.0 mm2 if the cable is not mechanically protected, (2.5 mm2 if
mechanically protected).
2.2.3 Supply cable - refer to: 'Electrical Checklist'.
2.2.4 As a guide only, and in accordance with BS 7671 we recommend close
circuit protection:
i.e. 9.8 kW @ 240 V = 45 Amp (9.0 kW @ 230 V = 40 Amp).
It is strongly recommended that a 30 mA Residual Current Device (RCD)
is included in the electrical circuit. This may be part of the consumer unit
or a separate unit.
A separate, permanently connected supply is taken from the consumer
unit to the appliance through a double-pole switch, which has at least
3 mm contact separation. The switch can be a ceiling mounted pullcord
type within the shower room or a wall mounted switch in an adjacent
room.
2.2.5 DO NOT twist the individual cable cores of either the live or neutral
conductors, as this will prevent them from entering the terminal block.
2.2.6 DO NOT exert strain on the terminal block. Ensure that the electrical
connections are tightly screwed down.
2.2.7 DO NOT turn on the electrical supply until the plumbing has been
completed.
14
Installation
Mira Elite ST
Read the section 'Important Safety Information' first.
1.
↑
↓
2.
200 mm
3.
Medium
Low
Electrical supply is turned
off at the mains.
4.
High
200 mm minimum gap
from ceiling.
5.
Remove the cover and
determine supply pipe
position.
7.
Remove the four cover
screws.
6.
For rear inlet, use
soldered elbow.
Do not trap green wire.
8.
CAUTION! Do not
drill into buried cables
or pipes.
9.
Flush a minimum
of 10 litres through
pipework.
* Alternative fixings for some wall structures are not supplied.
Drill and plug* the
three holes using the
template.
Fit Rubber Feet and fix
appliance to wall.
15
10.
11.
Feed cable into Case. Fit Earth
sleeve (not supplied) and strip
insulation.
Do not twist cable cores.
Connect supply pipe. Do not
overtighten!
12.
L = BROWN
13.
E = GREEN
N = BLUE
Firmly connect the conductors.
Do not exert strain on the
terminal block.
14.
Make sure wires are clear of all
mounting holes.
15.
Medium
Low
Refit the Service Tunnel and
Cover. Make sure they fit
correctly.
Do not overtighten screws.
High
Do not use alternative screws
to secure the Cover. This can
cause internal damage to the
appliance.
Do not seal around the back of
appliance.
16
Mira Logic Electric Shower Fittings
Read the section 'Important Safety Information' first.
1.
Clamp Bracket
2.
Button
Applicator
Soap Dish/Retaining
Ring
25 mm Minimum
Slide Bar
Spill-over level
Depress button FULLY and
assemble Clamp Bracket.
Release button and remove
Applicator.
Position as shown to prevent
back siphonage.
3.
4.
Lock Features
Slide the Soap Dish/Hose
Retaining Ring and the Soap
Dish Support collar onto the
Slide Bar below the Clamp
Bracket.
Fit both the top and bottom
Supports. Make sure the slots
are aligned to fit fully home.
17
5.
6.
CAUTION! Do not drill into
buried cables or pipes.
Mark the position of the middle
slot on both top and bottom
Supports.
7.
8.
First fix the bottom Slide Bar
Support and fully tighten the
screw*. Then fix the top Slide
Bar support whilst pressing
it down, to keep the whole
assembly together.
9.
Fit the End Caps to the Slide
Bar supports.
Fit the Hose to both the
Handset and the Shower Outlet,
remembering to pass it through
the Soap Dish/Hose Retaining
Ring. Do not overtighten the
Hose connections.
Hose Retaining
Ring
* Alternative fixings for some wall structures are not supplied.
18
Commissioning
If you are unsure how electric showers work, please read through the 'User
Instructions' Section before continuing.
1.
2.
3.
Power
Low Flow
Medium
Low
High
Temperatur e
Electrical supply is
turned off at the mains.
4.
Power
Low Flow
Medium
Low
High
Turn water supply fully on.
Turn BOTTOM control
to full cold.
5.
Start Stop
6.
Temperatur e
Start Stop
Check for water leaks.
7.
Turn TOP control to
LOW.
8.
Switch on electrical supply.
9.
LD
CO
0-5 secs
Push START button.
10.
Water will be at full force
and at a cool temperature.
11.
Turn BOTTOM control
slowly. Temperature remains
cool and flow is reduced.
12.
+
_
0-5 secs
Turn BOTTOM control
to full cold.
Set the TOP control to
MEDIUM.
19
The temperature will rise
slightly.
13.
14.
+
_
0-5 secs
Set the TOP control to HIGH.
15.
The temperature will rise further.
16.
Power
Adjust temperature as required.
Flow rate will adjust automatically.
17.
Press STOP and isolate power.
18.
0-5 secs
The shower will purge water from
its tank for a few seconds.
Residual water may drain over
a few minutes.
20
User Instructions
=
=
=
COLD
Medium
Low
High
Stop Start
-
+
-
+
Operation of the Mira Elite ST
21
Using Your Shower
Read the section 'Important Safety Information' first.
1.
2.
Switch on electrical supply.
3.
Press START button.
4.
+
_
Set to desired position.
Check water temperature before
entering shower.
5.
+
_
Allow 10-15 seconds for any temperature adjustments to reach the handset.
6.
7.
Power
Press STOP button. Shower
will continue to run for a few
seconds before stopping.
A small amount of water may
continue to drain over a few
minutes.
22
Changing the Spray Setting
The handset has four different spray settings (Eco, Start, Soothe and Force).
1.
2.
Eco
Turn the Spray Plate fully
clockwise. A reduced flow of
water will flow from the outer
set of holes.
3.
Start
Turn the Spray Plate
anticlockwise until it 'clicks'.
Water will flow from the outer
set of holes.
4.
Soothe
Turn the Spray Plate
anticlockwise until it 'clicks'.
Water will flow from the middle
set of holes.
Force
Turn the Spray Plate
anticlockwise until it 'clicks'.
Water will flow from the inner
set of holes.
Adjusting the Clamp Bracket
1.
Release Button
2.
Clamp Bracket
Assembly
Depress the release button
and slide the Clamp Bracket
assembly to the required
position.
Move the handset to the required
angle.
23
Fault Diagnosis
The trouble shooting information below gives details on probable causes and remedies should difficulties
be encountered whilst the shower is in operation.
Warning! There are no user serviceable components beneath the cover of the appliance.
ONLY A COMPETENT TRADESPERSON SHOULD REMOVE THE FRONT COVER!
Symptom
Power
Light
Low
Flow
Light
Heater Setting
Low / Medium
/ High
Elite ST fails
to operate.
OFF
OFF
Any
Electrical supply isolated S w i t c h o n e l e c t r i c a l
at double pole switch.
supply via pullcord or
wall mounted switch.
OFF
OFF
Any
Fuse blown or MCB/RCD
tripped indicating possible
Renew the fuse or reset
electrical fault.
the MCB/RCD. If fault
persists, contact your
installer.
No water
or very low
flow rate.
ON
ON
Any
H o s e o r h a n d s e t Remove and clean.
sprayplate blocked.
ON
ON
Any
Incoming water supply Turn isolating valve to
isolating valve turned fully on position.
down or off.
Shower
cycles from
hot to cold.
ON
OFF
Medium / High Temperature knob or Turn the TOP knob to
heater setting too high.
MEDIUM setting and
re‑adjust temperature
knob until suitable
temperature is achieved.
ON
ON
Medium / High H a n d s e t s p r a y p l a t e Remove and clean.
blocked.
ON
OFF
Unable to
select a cool
enough
temperature.
High
Probable Cause
Due to a rise in the stored
water temperature, the
power rating may be too
high.
24
Possible Remedy
Turn the TOP knob to
MEDIUM setting and
re‑adjust temperature
knob until suitable
temperature is achieved.
Symptom
No water
and motor
tone
increases.
Power
Light
Low
Flow
Light
Heater Setting
Low / Medium
/ High
Probable Cause
Possible Remedy
ON
ON
ON
ON
Any
Cistern has run out of Turn off the Elite ST
water.
immediately and resolve
cistern storage difficulty.
ON
ON
Any
Internal pump unit faulty Wait for internal pump /
o r t h e r m a l t r i p h a s shower to cool down. If
operated.
still faulty contact your
installer.
Medium / High H a n d s e t s p r a y p l a t e Remove Handset and
blocked.
clean.
ALL OF THE FOLLOWING REMEDIES MUST ONLY BE PERFORMED BY A
COMPETENT TRADESPERSON!
Handset
dripping.
OFF
OFF
Any
Flow Valve faulty.
Replace.
Low or no
flow.
ON
ON
Any
Filter or water supply Flush supply pipe.
pipework restricted by Clean filter.
a blockage or partial
blockage.
ON
ON
Any
Insufficient water supply G r a v i t y f e d s y s t e m ,
p r e s s u r e / f l o w f o r minimum pressure 0.8
operation.
kPa (0.008 Bar / 80
mm).
ON
OFF
Any
H o s e o r h a n d s e t Remove and clean.
sprayplate blocked.
ON
ON
OFF
OFF
Any
Any
Flow Valve faulty.
Replace.
Heater tank excessively Replace. In hard water
scaled.
areas consider the use
of a water softener.
(Continued . . .)
25
Symptom
Power
Light
Low
Flow
Light
Heater Setting
Low / Medium
/ High
Probable Cause
Possible Remedy
ON
OFF
Any
Service tunnel or cover
not fitted correctly causing
Start/Stop button not to
operate.
Check case inserts are
cut and fitted correctly.
Check services
(electrical / plumbing)
are not interfering with the
location of service tunnel
or cover.
ON
OFF
Any
Pump faulty.
Replace.
ON
ON
Medium / High Hose, handset or Filter Remove and clean.
blocked.
ON
OFF
Medium / High Flow Valve faulty.
Replace.
ON
OFF
Medium / High Heater Tank failure.
Replace.
ON
OFF
Medium / High Microswitch failure.
Replace.
No
change in
temperature
between
Low /
Medium/
High
settings.
ON
OFF
Water will
not turn off.
ON
OFF
Medium / High Flow Valve, Solenoid or R e p l a c e
Start/Stop switch faulty. required.
Appliance
fails to
produce
hot water
when set
on Medium /
High heater
setting.
ON
OFF
Medium / High Possible Microswitch or Use a suitable continuity
Thermal Switch failure.
device to check the
continuity of the
Microswitch or Heater
Tank and replace parts
as required.
ON
OFF
Medium / High Possible Heater Tank Replace.
failure.
Operation of
Temperature
Control
has little or
no effect
on water
temperature.
Any
Possible Flow Valve, Use a suitable continuity
Microswitch or Heater d e v i c e t o c h e c k t h e
Tank failure.
continuity of the
Microswitch or Heater
Tank and replace parts
as required.
26
parts
as
Maintenance
Handset - Cleaning
Clean with mild washing up detergent or
soap solution. Wipe dry with soft cloth.
R
EA
CL
Poor shower performance can be
avoided by descaling the spray head,
which must be done regularly. Use
thumb or soft cloth to wipe rubber
nozzles.
Filter - Cleaning/Renewing
Read the section 'Important Safety Information' first.
1.
2.
3.
Power
Low Flow
Medium
Low
High
Temperatur e
Electrical supply is turned
off at the mains.
4.
Turn water supply fully
off.
Start Stop
Remove the four screws
and the Cover.
Press down on the filter cover and turn
anti-clockwise to release.
Remove the filter cover and filter.
Clean the filter and wipe the inside of the
filter housing to remove any debris.
Replace the filter ensuring it is located over
the pins in the filter body.
Refit in reverse order, making sure that the
O-ring is correctly seated.
27
Dimensions
95 mm
266 mm
Power
Low Flow
Medium
Low
High
340 mm
Temperatur e
Start Stop
344 mm
659 mm
28
Wiring Diagram
PRESSURE / POWER
SELECTOR SWITCH
HIGH
RED
LOAD
LOW
LOW FLOW
NEON
BROWN
RED
BROWN
THERMAL
CUTOUT
DUAL DISC
BLACK
THERMAL
TRIP
BLUE
ORANGE
BLUE
MOTOR
BROWN
N
L
C 0.1u
BLACK
SOLENOID VALVE
L
N
29
E
GREEN
STOP/START
GREEN
BLUE
BLUE
POWER
ON NEON
BROWN
INLET CONNECTOR
BROWN
BLACK
TANK CONNECTION
Spare Parts
Mira Elite ST Spare Parts List
215 12Thermal Trip Pack
416 38Clamp Bracket
416 41Thermal Switch
416 43
Splash Guard
416 48Latching Switch
416 51
Solenoid Coil Assembly
428 56Cover Seal (not shown)
428 59
Service Tunnel
428 61Transfer/Inlet Tubes
428 62Motor/Pump Assembly
428 64Motor Dust Shield
872 01Microswitch N/O - 2 pin
872 28Microswitch C/O - 3 pin
1563 516Outlet Connector
1563 504Heater Tank 9.8 kW
1563 507 Flow Valve Assembly
1563 509 Switch Assembly
1563 604Cover Assembly
1563 605 Component Pack - components identified 'A'
1563 606Terminal Block Assembly
1563 607Wire Harness Assembly
1563 608 Screw Pack - components identified 'B'
1563 679 Filter Assembly Spare
1563 687 Filter Tube and Seal Pack - components identified 'C'
1563 691 Filter
Important note!
Push-fit connectors must be assembled
back to back onto the micro-switch
terminals.
A minimum air gap of 4 mm must be
maintained between the connectors after
assembly.
4 mm minimum
30
Mira Elite ST Spare Parts Diagram
B
B
A
A
416 41
A
416 43
1563 607
1563 606
A
1563 504
1563 509
872 01
B
872 28
B
A
A
B
428 59
B
B
416 38
215 12
428 62
1563 507
B
NING
V
WAR
23 0 T
NO
DOMO VE
RE IELD
SH
C C
C
416 48
416 51
428 64
C
A
1563.679
1563.691
1563 604
31
1563 516
B
Mira Logic Electric Shower Fittings Spare Parts List
450.01Hose 1.25 m - chrome
450.03
Adjuster Ring
450.06Clamp Bracket Assembly - white
450.08
Service Pack 'O' seals - components identified 'A'
450.17
Slide Bar Wall Fixing Pack - components identified 'B'
450.26
Slide Bar Support Assembly - white - components identified 'D'
450.28
Slide Bar - chrome
450.36LC Spray Plate Pack - white
632.73Hose Washer
1563.257 Adjustable Handset Assembly
1563.552 Soap Dish/Hose Retaining Ring
Mira Logic Electric Shower Fittings Spare Parts Diagram
D
B
1563.257
A
450.28
450.36
632.73
450.06
1563.552
450.01
D
B
32
450.03
Optional Accessories
DCV-H: An outlet double check valve, designed to prevent the backflow or backsiphonage of potentially contaminated water, through shower controls which are
fitted with a flexible hose as part of the outlet shower fitting. Available as an optional
accessory from your Kohler Mira stockists.
33
Notes
34
Notes
35
Customer Service
UKAS
1056830-W2-B
36
© Kohler Mira Limited, July 2006