Download Mira Elite ST - Plumb Center Online
Transcript
Pumped Electric Shower Installation and User Guide These instructions are to be left with the user Contents Introduction................................................................................................. 3 Important Safety Information...................................................................... 4 Pack Contents Checklist............................................................................ 6 1. Mira Elite ST...................................................................................... 6 2. Documentation.................................................................................. 6 3. Mira Logic Electric Shower Fittings................................................... 7 Specifications............................................................................................. 8 1. Plumbing........................................................................................... 8 2. Electrical............................................................................................ 8 3. Standards and Approvals.................................................................. 8 Installation Requirements........................................................................... 9 1. Plumbing........................................................................................... 9 2.1 Electrical........................................................................................ 13 2.2 Electrical (checklist in detail)......................................................... 14 Installation................................................................................................ 15 Mira Elite ST........................................................................................ 15 Mira Logic Electric Shower Fittings..................................................... 17 Commissioning......................................................................................... 19 User Instructions...................................................................................... 21 Using Your Shower.............................................................................. 22 Fault Diagnosis......................................................................................... 24 Maintenance............................................................................................. 27 Handset - Cleaning.............................................................................. 27 Filter - Cleaning/Renewing.................................................................. 27 Dimensions............................................................................................... 28 Wiring Diagram......................................................................................... 29 Spare Parts.............................................................................................. 30 Mira Elite ST Spare Parts List............................................................. 30 Mira Logic Electric Shower Fittings Spare Parts List........................... 32 Optional Accessories................................................................................ 33 Notes........................................................................................................ 34 Customer Service........................................................................Back Page Introduction Thank you for purchasing a quality Mira product. To exploit the full potential of your new product, please take time to read this guide thoroughly. Having done so, keep it handy for future reference. The Mira Elite ST is a tank-fed (cistern-fed) pumped electric shower for use where the mains water supply pressure is too low, unreliable or non existent, to operate a conventional electric shower. The Mira Elite ST features an internal pump unit which has been designed to provide all year round performance, even at the highest flow rates which are necessary during the summer months. The Elite ST has separate controls for power selection and temperature/flow adjustment. The Elite ST must have its own separate cold water supply from the cistern to ensure correct operation. The Mira Elite ST comes complete with a set of Mira Logic Electric Shower Fittings. Products Covered By This Guide: Mira Elite ST - A 9.8 kW @ 240 Volts AC (9.0 kW @ 230 Volts AC) heater. Available in white/chrome finish. Mira Logic Electric Shower Fittings An adjustable spray handset with four different spray actions (start, soothe, force and eco), supplied complete with flexible hose, clamp bracket assembly, slide bar, supports, soap dish/hose retaining ring. Available in white/chrome finish. If you experience any difficulty with the installation or operation of your new shower control, then please refer to "Fault Diagnosis", before contacting Kohler Mira Limited. Our telephone and fax numbers can be found on the back cover of this guide. Important Safety Information 1. Warning! 1.1 Products manufactured by us are safe and without risk provided they are installed, used and maintained in good working order in accordance with our instructions and recommendations. 1.2 This Appliance must be earthed. MAKE SURE SUPPLEMENTARY BONDING COMPLIES WITH THE "REQUIREMENTS FOR ELECTRICAL INSTALLATIONS". In accordance with the current edition of BS 7671 ‘The IEE Wiring Regulations' in force at the time of installation. This appliance is intended to be permanently connected to the fixed electrical wiring of the mains system with its own dedicated supply. 1.3 DO NOT twist the individual cable cores of the live and neutral conductors, as this will prevent them from entering the terminal block. 1.4The shower unit must NOT be fitted where it may be exposed to freezing conditions. Make sure that any pipework that could become frozen is properly insulated. 1.5 DO NOT operate this appliance if it appears to be frozen. Allow the appliance to thaw and then contact your installer before using again. 1.6There are no user serviceable components beneath the cover of this appliance. Only a competent tradesperson should remove the cover. If the cover is removed, the following warnings must be observed: 1.6.1Turn off the electrical and water supplies before removing the cover. 1.6.2Mains connections are exposed when the cover is removed. 1.6.3Refer to the wiring diagram before making any electrical connections (see section "Wiring Diagram"). 1.6.4Make sure all electrical connections are tight, to prevent them overheating. 1.7 If any of the following conditions occur, isolate the electricity and water supplies. Contact your installer or refer to “To contact us”, on the back page of this guide: 1.7.1 If water is leaking from inside the product. 1.7.2 If the case is damaged. 1.7.3 If the appliance begins to make an odd noise, smell or smoke. 1.7.4 If the appliance shows signs of a distinct change in performance, indicating a need for maintenance. 1.7.5 If the cover is not correctly fitted. 1.8 DO NOT fit any form of outlet flow control as the outlet acts as a vent for the tank body. Only Mira recommended outlet fittings should be used. 2. Caution! 2.1Read all of these instructions and retain this guide for later use. 2.2 Pass on this guide in the event of change of ownership of the installation site. 2.3 Follow all warnings, cautions and instructions contained in this guide, and on or inside the appliance. 2.4The electrical installation must comply with the “Requirements for Electrical Installations” (see section "Installation Requirements") commonly referred to as BS 7671 the IEE Wiring Regulations, or any particular regulations and practices, specified by the local electricity supply company in force at the time of installation. The installation should be carried out by an electrician or contractor who is registered, or is a member of, an association such as: 2.4.1 National Inspection Council for Electrical Installation and Contracting (NICEIC), throughout the UK. 2.4.2The Electrical Contractors Association (ECA), England and Wales. 2.4.3The Electrical Contractors Association of Scotland (ECAS). 2.5The plumbing installation must comply with the requirements of UK Water Regulations/Bye-laws (Scotland), Building Regulations or any particular regulations and practices, specified by the local water company. The installation should be carried out by a plumber or contractor who is registered, or is a member of, an association such as: 2.5.1 Institute of Plumbing (IOP), throughout the UK. 2.5.2 National Association of Plumbing, Heating and Mechanical Services Contractors (NAPH & MSC), England and Wales. 2.5.3 Scottish and Northern Ireland Plumbing Employers’ Federation (SNIPEF), Scotland and Northern Ireland. 2.6 Anyone who may have difficulty understanding or operating the controls of any shower should be attended whilst showering. Particular consideration should be given to the young, the elderly, the infirm, or anyone inexperienced in the correct operation of the controls. 2.7When this appliance has reached the end of its serviceable life, it should be disposed of in a safe manner, in accordance with current local authority recycling, or waste disposal policy. Pack Contents Checklist Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included. 1. Mira Elite ST 1 x Case Insert 3 x Rubber Feet 1 x Olive 1 x Compression Nut 3 x Fixing Screws 3 x Wall Plugs 1 x Mira Elite ST 2. Mira Logic Electric Shower Fittings 2 x Wall Plugs 2 x Fixing Screws 2 x Slide Bar End Caps 2 x Slide Bar End Supports 1 x Applicator 1 x Handset 1 x Slide Bar 2 x Hose Seals 1 x Clamp Bracket Assembly 1 x 1.25 m Flexible Hose 1 x Soap Dish/Hose Retaining Ring 1 x Soap Dish Collar 3. Documentation 1 x Installation and User Guide 1 x Installer Checklist 1 x Guarantee Card 1 x Template (Use inner fitment) Specifications 1. Plumbing 1.1 The 15 mm inlet compression connector incorporates an inlet filter. The inlet swivels to allow top, bottom or rear entry. 1.2The outlet terminates with a 1/2" BSP male thread for connection to a Mira flexible shower hose. 2. Electrical This is a high power unit, it is essential to contact your electricity supply company to make sure that the electricity supply is adequate for the purpose. 2.1The terminal block will not accept cable larger than 16 mm2. 2.2 The motor is fitted with a self resetting thermal trip protection device, designed to operate if the ambient temperatures become too high. The maximum recommended ambient temperature for the Elite ST is 30°C. 2.3The following power ratings for the heater tanks are available with their respective voltages: Mira Elite ST 9.8 kW @ 240 V / 45 Amps (9.0 kW @ 230 V / 40 Amps). 2.4The motor will absorb approximately 100 Watts maximum power under normal working conditions. 3. Standards and Approvals 3.1The Mira Elite ST has been designed to comply with the requirements of the British Electrotechnical Approvals Board (BEAB) and the requirements of UK Water Regulations/Bye-laws (Scotland). 3.2This Mira Elite ST complies with all relevant directives for CE marking. Installation Requirements 1. Plumbing Read the section 'Important Safety Information' first. 1.1The Elite ST is designed to operate with water supply pressures from 0.8 kPa (0.008 bar / 80 millimetres head) to 100 kPa (1 bar / 10 metres head) (i.e. the vertical distance from the base of the cold cistern to the top of the Elite ST). However, the minimum head required will increase with pipe length and the guide given in paragraph 1.17 should be used to make sure that adequate head is available for any given installation. The Elite ST MUST have its own separate supply from the cistern. 25 Gallon/113 Ltr Cistern Correct Cistern Take Off 25 mm Positioned away from the ball valve, with a 25 mm distance up from the base of the cistern. This connection will prevent air and debris entering the shower supply. Incorrect Cistern Take Off Debris from the bottom of the cistern and air generated when the cistern refills will enter the shower supply. 1.2 The Elite ST is suitable for installation within the shower area and is fitted with a pressure relief valve. It must be positioned over a water catchment area with the controls at a convenient height. The shower fitting should be positioned so that it discharges down the centre line of the bath, or across the opening of a shower cubicle, and must be directed away from the shower unit. 1.3 Use a minimum of 15 mm diameter supply pipework. It should be noted, however, that on long pipe runs this should be increased to 22 mm (refer to para 1.17 for guidance). When using flexible plastic pipe it is essential that the pipe is kept flat and not looped up at any point as this may lead to air build up which may impair performance of the shower. 1.4 A non restrictive (free flowing) isolating valve should be fitted into the supply from the cold water cistern, for maintenance purposes. 1.5 The Elite ST must be fitted onto the finished wall surface i.e. on top of the tiles. Do not block the air ventilation gaps around the sides of the unit, either by tiling up to the sides of the unit or by using a sealant around the case. Important! This Elite ST is designed to be ventilated. Failure to do this may cause product failure. Note! The Mira Elite ST is fitted with a pump motor, and some mechanical noise can be expected in addition to the noise generated by the spray from the handset. The type of wall surface will affect the perceived sound levels. Stud partition and panel walls have a tendency to resonate, whilst solid walls provide the quietest operation. The tone of the pump motor may change when the temperature control knob is adjusted. This is quite normal. 1.6 Inlet: 15 mm inlet compression connector is designed to accept plumbing supplies from the top, bottom or rear. 1.7Rear entry plumbing is accommodated without the need to recess the 15 mm inlet compression connector, enabling the wall’s surface to be completed and sealed to prevent water ingress, before final fitting. 1.8 Swivel the inlet connector assembly to suit (not directly back into the wall). Avoid trapping the green earth bonding wire. 1.9 Use only the 15 mm inlet compression connector supplied with the Elite ST, do not use any other types of fitting. 1.10Outlet: 1/2" BSP male, to accept Mira flexible hose. 1.11Refrain from applying excessive force when making connections. Note! Excessive force on the pump housing can impair pumping performance. Make sure that the supply pipe is trimmed and bent such that the 15 mm inlet connector sits (or can be lightly pressed) easily on the back of the clamp bracket prior to connection with the pump housing. 1.12To avoid damage to the case when soldered fittings are used, pre-solder the pipework and fittings before connecting them to the 15 mm inlet compression connector. 1.13Supply pipework MUST be flushed to clear debris before connecting the Elite ST. 10 1.14A hose retaining ring is supplied to prevent the handset from dropping below the spillover level of the bath or shower, which could lead to contamination from back-siphonage (refer to illustration). The supplied hose retaining ring should meet the great majority of user requirements for shower installations with flexible outlet fittings. However, there will be occasions when the hose retaining ring will not provide a suitable solution. In these instances an outlet double checkvalve, e.g. the Mira DCV-H, must be fitted. The inclusion of the Mira DCV-H will increase the required supply pressure typically by 10 kPa (0.1 bar). Double checkvalves, fitted in the inlet supply to the appliance, cause a pressure build-up, which could exceed the maximum static inlet pressure for the appliance. 1.15When installed in very hard water areas (above 200 ppm temporary hardness) your installer may advise the installation of a water treatment device, to reduce the effects of limescale formation. Your local water company will be able to advise the hardness of water in your area. 1.16Avoid layouts where the hose will be sharply kinked. This may reduce the life of the hose. Soap Dish/Hose Retaining Ring 25 mm Minimum Spill-over Level 1.17Long pipe runs and excessive use of 90° elbows will significantly reduce the available head to supply the Elite ST. The pipework table should be completed to ensure that adequate head is available for any given application. 11 Pipework The dimension (x) is calculated from the table below to give you a minimum effective head of 80 mm which is necessary to produce a satisfactory shower in all conditions. Plumbing Schematic Diagram A B X Example!The example below is based on the diagram above with 15 mm pipework, A = 1.5 m, B = 0.75 m. Head Loss (mm) Quantity Size 15 mm Pipe (A) 22 mm Pipe (A) 1.5 + (B) 0.75 + (B) = 2.25 = 15 mm Elbow Number of Elbows 22 mm Elbow Number of Elbows x 120 270 x 20 1 x 55 55 x 15 Minimum Effective Head 80 (x) mm 405 12 2.1 Electrical Read the section 'Important Safety Information' first. Checklist 2.1.1 Electrical supply fuse and consumer unit are adequate for the product. 2.1.2 Shower unit is earthed. 2.1.3 The minimum required supply cable size must conform to BS 7671. 2.1.4 Double pole isolating switch. 2.1.5 Do not twist live or neutral cable cores. 2.1.6 Electrical connections are tightly secured. Do not strain terminal block. 2.1.7 Plumbing supply completed before electrical supply is turned on. Plumbing and Electrical Schematic Diagram Cold Water Storage Cistern (Tank) Cold Water Mains Feed Warning Pipe Hot Water Cylinder Vent Pipe Independent Cold Water Supply to Shower Isolating Valve Consumer Unit Cistern Fed Cold Supply to Other Outlets Soap Dish/ Hose Retaining Ring Hot Water Cylinder Feed 13 Double Pole Isolating Switch 2.2Electrical (checklist in detail) 2.2.1 In a domestic installation, the rating of the electricity supplier's fuse and the consumer unit must be adequate for the additional demand. The Mira Elite ST is a high power unit, therefore it is essential to contact your electricity supplier to ensure that the supply is adequate for the product. Voltage drop due to local heavy demand will reduce the shower's performance. 2.2.2 The Mira Elite ST must be earthed by connecting the supply-cable earth conductor to the earth terminal. Supplementary bonding: Within the bathroom or shower room, all accessible conductive parts of electrical equipment and extraneous conductive parts (metal parts) that are likely to introduce earth potential, must be electrically bonded to earth using a minimum cable size of 4.0 mm2 if the cable is not mechanically protected, (2.5 mm2 if mechanically protected). 2.2.3 Supply cable - refer to: 'Electrical Checklist'. 2.2.4 As a guide only, and in accordance with BS 7671 we recommend close circuit protection: i.e. 9.8 kW @ 240 V = 45 Amp (9.0 kW @ 230 V = 40 Amp). It is strongly recommended that a 30 mA Residual Current Device (RCD) is included in the electrical circuit. This may be part of the consumer unit or a separate unit. A separate, permanently connected supply is taken from the consumer unit to the appliance through a double-pole switch, which has at least 3 mm contact separation. The switch can be a ceiling mounted pullcord type within the shower room or a wall mounted switch in an adjacent room. 2.2.5 DO NOT twist the individual cable cores of either the live or neutral conductors, as this will prevent them from entering the terminal block. 2.2.6 DO NOT exert strain on the terminal block. Ensure that the electrical connections are tightly screwed down. 2.2.7 DO NOT turn on the electrical supply until the plumbing has been completed. 14 Installation Mira Elite ST Read the section 'Important Safety Information' first. 1. ↑ ↓ 2. 200 mm 3. Medium Low Electrical supply is turned off at the mains. 4. High 200 mm minimum gap from ceiling. 5. Remove the cover and determine supply pipe position. 7. Remove the four cover screws. 6. For rear inlet, use soldered elbow. Do not trap green wire. 8. CAUTION! Do not drill into buried cables or pipes. 9. Flush a minimum of 10 litres through pipework. * Alternative fixings for some wall structures are not supplied. Drill and plug* the three holes using the template. Fit Rubber Feet and fix appliance to wall. 15 10. 11. Feed cable into Case. Fit Earth sleeve (not supplied) and strip insulation. Do not twist cable cores. Connect supply pipe. Do not overtighten! 12. L = BROWN 13. E = GREEN N = BLUE Firmly connect the conductors. Do not exert strain on the terminal block. 14. Make sure wires are clear of all mounting holes. 15. Medium Low Refit the Service Tunnel and Cover. Make sure they fit correctly. Do not overtighten screws. High Do not use alternative screws to secure the Cover. This can cause internal damage to the appliance. Do not seal around the back of appliance. 16 Mira Logic Electric Shower Fittings Read the section 'Important Safety Information' first. 1. Clamp Bracket 2. Button Applicator Soap Dish/Retaining Ring 25 mm Minimum Slide Bar Spill-over level Depress button FULLY and assemble Clamp Bracket. Release button and remove Applicator. Position as shown to prevent back siphonage. 3. 4. Lock Features Slide the Soap Dish/Hose Retaining Ring and the Soap Dish Support collar onto the Slide Bar below the Clamp Bracket. Fit both the top and bottom Supports. Make sure the slots are aligned to fit fully home. 17 5. 6. CAUTION! Do not drill into buried cables or pipes. Mark the position of the middle slot on both top and bottom Supports. 7. 8. First fix the bottom Slide Bar Support and fully tighten the screw*. Then fix the top Slide Bar support whilst pressing it down, to keep the whole assembly together. 9. Fit the End Caps to the Slide Bar supports. Fit the Hose to both the Handset and the Shower Outlet, remembering to pass it through the Soap Dish/Hose Retaining Ring. Do not overtighten the Hose connections. Hose Retaining Ring * Alternative fixings for some wall structures are not supplied. 18 Commissioning If you are unsure how electric showers work, please read through the 'User Instructions' Section before continuing. 1. 2. 3. Power Low Flow Medium Low High Temperatur e Electrical supply is turned off at the mains. 4. Power Low Flow Medium Low High Turn water supply fully on. Turn BOTTOM control to full cold. 5. Start Stop 6. Temperatur e Start Stop Check for water leaks. 7. Turn TOP control to LOW. 8. Switch on electrical supply. 9. LD CO 0-5 secs Push START button. 10. Water will be at full force and at a cool temperature. 11. Turn BOTTOM control slowly. Temperature remains cool and flow is reduced. 12. + _ 0-5 secs Turn BOTTOM control to full cold. Set the TOP control to MEDIUM. 19 The temperature will rise slightly. 13. 14. + _ 0-5 secs Set the TOP control to HIGH. 15. The temperature will rise further. 16. Power Adjust temperature as required. Flow rate will adjust automatically. 17. Press STOP and isolate power. 18. 0-5 secs The shower will purge water from its tank for a few seconds. Residual water may drain over a few minutes. 20 User Instructions = = = COLD Medium Low High Stop Start - + - + Operation of the Mira Elite ST 21 Using Your Shower Read the section 'Important Safety Information' first. 1. 2. Switch on electrical supply. 3. Press START button. 4. + _ Set to desired position. Check water temperature before entering shower. 5. + _ Allow 10-15 seconds for any temperature adjustments to reach the handset. 6. 7. Power Press STOP button. Shower will continue to run for a few seconds before stopping. A small amount of water may continue to drain over a few minutes. 22 Changing the Spray Setting The handset has four different spray settings (Eco, Start, Soothe and Force). 1. 2. Eco Turn the Spray Plate fully clockwise. A reduced flow of water will flow from the outer set of holes. 3. Start Turn the Spray Plate anticlockwise until it 'clicks'. Water will flow from the outer set of holes. 4. Soothe Turn the Spray Plate anticlockwise until it 'clicks'. Water will flow from the middle set of holes. Force Turn the Spray Plate anticlockwise until it 'clicks'. Water will flow from the inner set of holes. Adjusting the Clamp Bracket 1. Release Button 2. Clamp Bracket Assembly Depress the release button and slide the Clamp Bracket assembly to the required position. Move the handset to the required angle. 23 Fault Diagnosis The trouble shooting information below gives details on probable causes and remedies should difficulties be encountered whilst the shower is in operation. Warning! There are no user serviceable components beneath the cover of the appliance. ONLY A COMPETENT TRADESPERSON SHOULD REMOVE THE FRONT COVER! Symptom Power Light Low Flow Light Heater Setting Low / Medium / High Elite ST fails to operate. OFF OFF Any Electrical supply isolated S w i t c h o n e l e c t r i c a l at double pole switch. supply via pullcord or wall mounted switch. OFF OFF Any Fuse blown or MCB/RCD tripped indicating possible Renew the fuse or reset electrical fault. the MCB/RCD. If fault persists, contact your installer. No water or very low flow rate. ON ON Any H o s e o r h a n d s e t Remove and clean. sprayplate blocked. ON ON Any Incoming water supply Turn isolating valve to isolating valve turned fully on position. down or off. Shower cycles from hot to cold. ON OFF Medium / High Temperature knob or Turn the TOP knob to heater setting too high. MEDIUM setting and re‑adjust temperature knob until suitable temperature is achieved. ON ON Medium / High H a n d s e t s p r a y p l a t e Remove and clean. blocked. ON OFF Unable to select a cool enough temperature. High Probable Cause Due to a rise in the stored water temperature, the power rating may be too high. 24 Possible Remedy Turn the TOP knob to MEDIUM setting and re‑adjust temperature knob until suitable temperature is achieved. Symptom No water and motor tone increases. Power Light Low Flow Light Heater Setting Low / Medium / High Probable Cause Possible Remedy ON ON ON ON Any Cistern has run out of Turn off the Elite ST water. immediately and resolve cistern storage difficulty. ON ON Any Internal pump unit faulty Wait for internal pump / o r t h e r m a l t r i p h a s shower to cool down. If operated. still faulty contact your installer. Medium / High H a n d s e t s p r a y p l a t e Remove Handset and blocked. clean. ALL OF THE FOLLOWING REMEDIES MUST ONLY BE PERFORMED BY A COMPETENT TRADESPERSON! Handset dripping. OFF OFF Any Flow Valve faulty. Replace. Low or no flow. ON ON Any Filter or water supply Flush supply pipe. pipework restricted by Clean filter. a blockage or partial blockage. ON ON Any Insufficient water supply G r a v i t y f e d s y s t e m , p r e s s u r e / f l o w f o r minimum pressure 0.8 operation. kPa (0.008 Bar / 80 mm). ON OFF Any H o s e o r h a n d s e t Remove and clean. sprayplate blocked. ON ON OFF OFF Any Any Flow Valve faulty. Replace. Heater tank excessively Replace. In hard water scaled. areas consider the use of a water softener. (Continued . . .) 25 Symptom Power Light Low Flow Light Heater Setting Low / Medium / High Probable Cause Possible Remedy ON OFF Any Service tunnel or cover not fitted correctly causing Start/Stop button not to operate. Check case inserts are cut and fitted correctly. Check services (electrical / plumbing) are not interfering with the location of service tunnel or cover. ON OFF Any Pump faulty. Replace. ON ON Medium / High Hose, handset or Filter Remove and clean. blocked. ON OFF Medium / High Flow Valve faulty. Replace. ON OFF Medium / High Heater Tank failure. Replace. ON OFF Medium / High Microswitch failure. Replace. No change in temperature between Low / Medium/ High settings. ON OFF Water will not turn off. ON OFF Medium / High Flow Valve, Solenoid or R e p l a c e Start/Stop switch faulty. required. Appliance fails to produce hot water when set on Medium / High heater setting. ON OFF Medium / High Possible Microswitch or Use a suitable continuity Thermal Switch failure. device to check the continuity of the Microswitch or Heater Tank and replace parts as required. ON OFF Medium / High Possible Heater Tank Replace. failure. Operation of Temperature Control has little or no effect on water temperature. Any Possible Flow Valve, Use a suitable continuity Microswitch or Heater d e v i c e t o c h e c k t h e Tank failure. continuity of the Microswitch or Heater Tank and replace parts as required. 26 parts as Maintenance Handset - Cleaning Clean with mild washing up detergent or soap solution. Wipe dry with soft cloth. R EA CL Poor shower performance can be avoided by descaling the spray head, which must be done regularly. Use thumb or soft cloth to wipe rubber nozzles. Filter - Cleaning/Renewing Read the section 'Important Safety Information' first. 1. 2. 3. Power Low Flow Medium Low High Temperatur e Electrical supply is turned off at the mains. 4. Turn water supply fully off. Start Stop Remove the four screws and the Cover. Press down on the filter cover and turn anti-clockwise to release. Remove the filter cover and filter. Clean the filter and wipe the inside of the filter housing to remove any debris. Replace the filter ensuring it is located over the pins in the filter body. Refit in reverse order, making sure that the O-ring is correctly seated. 27 Dimensions 95 mm 266 mm Power Low Flow Medium Low High 340 mm Temperatur e Start Stop 344 mm 659 mm 28 Wiring Diagram PRESSURE / POWER SELECTOR SWITCH HIGH RED LOAD LOW LOW FLOW NEON BROWN RED BROWN THERMAL CUTOUT DUAL DISC BLACK THERMAL TRIP BLUE ORANGE BLUE MOTOR BROWN N L C 0.1u BLACK SOLENOID VALVE L N 29 E GREEN STOP/START GREEN BLUE BLUE POWER ON NEON BROWN INLET CONNECTOR BROWN BLACK TANK CONNECTION Spare Parts Mira Elite ST Spare Parts List 215 12Thermal Trip Pack 416 38Clamp Bracket 416 41Thermal Switch 416 43 Splash Guard 416 48Latching Switch 416 51 Solenoid Coil Assembly 428 56Cover Seal (not shown) 428 59 Service Tunnel 428 61Transfer/Inlet Tubes 428 62Motor/Pump Assembly 428 64Motor Dust Shield 872 01Microswitch N/O - 2 pin 872 28Microswitch C/O - 3 pin 1563 516Outlet Connector 1563 504Heater Tank 9.8 kW 1563 507 Flow Valve Assembly 1563 509 Switch Assembly 1563 604Cover Assembly 1563 605 Component Pack - components identified 'A' 1563 606Terminal Block Assembly 1563 607Wire Harness Assembly 1563 608 Screw Pack - components identified 'B' 1563 679 Filter Assembly Spare 1563 687 Filter Tube and Seal Pack - components identified 'C' 1563 691 Filter Important note! Push-fit connectors must be assembled back to back onto the micro-switch terminals. A minimum air gap of 4 mm must be maintained between the connectors after assembly. 4 mm minimum 30 Mira Elite ST Spare Parts Diagram B B A A 416 41 A 416 43 1563 607 1563 606 A 1563 504 1563 509 872 01 B 872 28 B A A B 428 59 B B 416 38 215 12 428 62 1563 507 B NING V WAR 23 0 T NO DOMO VE RE IELD SH C C C 416 48 416 51 428 64 C A 1563.679 1563.691 1563 604 31 1563 516 B Mira Logic Electric Shower Fittings Spare Parts List 450.01Hose 1.25 m - chrome 450.03 Adjuster Ring 450.06Clamp Bracket Assembly - white 450.08 Service Pack 'O' seals - components identified 'A' 450.17 Slide Bar Wall Fixing Pack - components identified 'B' 450.26 Slide Bar Support Assembly - white - components identified 'D' 450.28 Slide Bar - chrome 450.36LC Spray Plate Pack - white 632.73Hose Washer 1563.257 Adjustable Handset Assembly 1563.552 Soap Dish/Hose Retaining Ring Mira Logic Electric Shower Fittings Spare Parts Diagram D B 1563.257 A 450.28 450.36 632.73 450.06 1563.552 450.01 D B 32 450.03 Optional Accessories DCV-H: An outlet double check valve, designed to prevent the backflow or backsiphonage of potentially contaminated water, through shower controls which are fitted with a flexible hose as part of the outlet shower fitting. Available as an optional accessory from your Kohler Mira stockists. 33 Notes 34 Notes 35 Customer Service UKAS 1056830-W2-B 36 © Kohler Mira Limited, July 2006