IDENT
DISPLAY SHOW
ACTION / COMMENTS
Note 1: When Multiple-Shot
Sampling is opted for, then
every reference to Sample
means XX Shots.
SYSSAM03
....Continued
Note 2: SHOTS / SAMPLE
is fixed at 01 for Samplers in
PPI Mode
Now see SYSSAM04.
SYSSAM04
INITIAL SAMPLE
YES
[NO]

You can choose to take a
Sample either at the beginning
of a Sampling Period or after
the first Time Interval / Flow
Increment.
When the application is to
obtain Flow Proportional
Samples then the Samples
should always be taken after
a certain volume of water has
passed the Sampling Point
and therefore an Initial Sample
should not be taken. Where
the requirement is to take
Samples from a Sampling
Point at equal Time Intervals
commencing at a certain
time then an Initial Sample is
sometimes appropriate.
Now see SYSSAM05.
SYSSAM05
SAMPLING MODE
TIME
[FLOW]

Samples can either be taken
at fixed Time Intervals or,
when coupled to a suitable
flowmeter, at equal Flow
Increments (see SAMPLING
FREQUENCY, page 6.16).
Select either TIME or FLOW.
If TIME see SYSSAM08.
If FLOW see SYSSAM06.
OPERATION
Select YES or NO.
6.23