Technical Data Operating currents 9.4.2 kVA i f n 9 P Hz Brakes BE5, BE11, BE20, BE30, BE32 The current values IH (holding current) listed in the tables are r.m.s. values. Use only appropriate instruments for measuring r.m.s. values. The inrush current (accelerator current) IB only flows for a short time (ca. 160 ms) when the brake is released. A direct DC voltage supply is not possible. BE5 BE11 BE20 BE30, BE32 40 (354) 80 (708) 150 (1328) 200/400 (1770/3540) Braking power [W (hp)] 39 (0.052) 61 (0.081) 79 (0.106) 103 (0.138) Inrush current ratio IB/IH 5.7 6.6 7 10 BE5 BE11 BE20 BE30, BE32 Max. braking torque [Nm (lb-in)] Nominal voltage VN AC V DC V IH IG IH IG IH IG IH IG [AC A] [DC A] [AC A] [DC A] [AC A] [DC A] [AC A] [DC A] 60 (57-63) 24 1.00 1.30 1.50 1.95 1.80 2.34 – – 120 (111-123) – 0.46 – 0.74 – 0.91 – 1.19 – 147 (139-159) – 0.36 – 0.59 – 0.73 – 0.94 – 184 (174-193) – 0.29 – 0.47 – 0.65 – 0.75 – 208 (194-217) – 0.26 – 0.42 – 0.52 – 0.67 – 230 (218-243) – 0.23 – 0.37 – 0.46 – 0.60 – 254 (244-273) – 0.21 – 0.33 – 0.41 – 0.54 – 290 (274-306) – 0.18 – 0.30 – 0.36 – 0.47 – 330 (307-343) – 0.16 – 0.26 – 0.32 – 0.42 – 360 (344-379) – 0.15 – 0.24 – 0.29 – 0.38 – 400 (380-431) – 0.13 – 0.21 – 0.26 – 0.34 – 460 (432-484) – 0.12 – 0.19 – 0.23 – 0.30 – 500 (485-542) – 0.10 – 0.17 – 0.21 – 0.27 – Key IB IH IG VN Acceleration current – brief inrush current Holding current r.m.s. value in the supply cable to the SEW brake rectifier Direct current with direct DC voltage supply Nominal voltage (nominal voltage range) Operating Instructions – Explosion-Proof AC Motors EDR.71 – 225 137