8.
Technical data
8.1
High Pressure System (HighPur)
HighPur 60
60 kg/h
Output
Operating pressure
120 kg/h
200 kg/h
8.5 MPa
Dimensions
600 x 400 x 400 mm
Weight
approx. 40 kg
Operating voltage
400 VAC, 3-phase, 50 Hz, ±10%
Power consumption
720 W
Overvoltage category
II
Pollution degree
2
Usage
Only in rooms
Altitude above mean sea level
2,000 m
Ambient temperature
7 -35°C
Ambient humidity
8.2
HighPur 120 HighPur 200
Max. 80 %, avoid condensation
HumCenter
Position
Dimensions
Weight
Operating voltage
Max. input current
Contact load capacity (floating
outputs, OUT1/2)
Overvoltage category
Pollution degree
Usage
Altitude above mean sea level
Ambient temperature/
humidity
Created: 07.02.2008
Changed: 11.08.2011
Printed: 11.08.2011
- 69 -
Wall-mounted
228 x 202 x 65 mm
0,7 Kg
100-240V AC, 50-60Hz ± 10 %
Max. 30W (Typ. 5W)
2A, 230VAC, 50-60 Hz
II
2
Only in rooms
2,000 m
7-35°C / Max. 80 %, avoid condensation