Download Door Interlock Installation Instructions
Transcript
DOOR INTERLOCK SYSTEM INSTALLATION MANUAL DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL _________________________________________________________________________________________________________________________________________________ CONTENTS SECTION PAGE 1. CONTROL AND DISTRIBUTION PANEL 2 2. FIELD WIRING 3 3. MAGNETIC LOCK AND PROXIMITY SWITCH 4 4. SLAVE INTERLOCK MODULE 5 5. REMOTE OVERRIDE MODULE 6 6. FIRE ALARM CONTROL 7 7. REMOTE RESET AND INDICATION 8 8. PUSH TO EXIT BUTTONS 9 9. INSTALLATION CHECKLIST BEFORE SWITCHING ON 10 10. SYSTEM DRAWINGS 11/12 _________________________________________________________________________________________________ technickon ltd, Unit 7, Boxmend Industrial Estate, Bircholt Road, Parkwood, Maidstone, Kent, ME15 9YG tel: (01622) 673300 fax: (01622) 673311 email: [email protected] web: www. technickon.co.uk -1- DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL _________________________________________________________________________________________________________________________________________________ 1. CONTROL AND DISTRIBUTION PANEL A. Locate the power and distribution panel within the ceiling void or wall mount to allow distribution of cables to each interlocked door. B. The power and distribution panel should be supplied from a switched fused spur, located no more than 1m away from the panel. The power supply requires a 240v 50Hz supply. _________________________________________________________________________________________________ technickon ltd, Unit 7, Boxmend Industrial Estate, Bircholt Road, Parkwood, Maidstone, Kent, ME15 9YG tel: (01622) 673300 fax: (01622) 673311 email: [email protected] web: www. technickon.co.uk -2- DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL _________________________________________________________________________________________________________________________________________________ 24vdc 0v 2. FIELD WIRING A. Each interlocked door in the system has a Master interlock module. Each master module requires six cores to be run from the control panel to each master module. The cable should be rated at 24vdc and matched to the fuse size installed on the PCB. IN + 1 2 3 4 5 6 ON D4 + 1 2 3 4 5 6 ON J4 ON D3 J3 1 2 3 4 5 6 J2 J IN ON ON 24VDC 0v 03 24VDC DOOR INTERLOCK SYSTEM 03 Terminal 1 Terminal 2 Terminal 3 Terminal 4 Terminal 5 Terminal 6 24VDC + 1 2 3 4 5 6 NAIS TK1 - 24V ATK104 JAPAN T5 CONTROL PANEL 00707 T4 1 2 3 4 5 6 53W/5 0313 A MALAYSIA J1 FIELD WIRING (To each interlocked door) ON – – – – – – PRESS TO RESET D2 + six core signal cable 1 Amp rated IN D4 IN 196-6298 Terminal 1 Terminal 2 Terminal 3 Terminal 4 Terminal 5 Terminal 6 (Door 1) IN D3 IN + RS Master Interlock Module (Door 1) D2 IN J5 J6 D1 1 2 3 4 5 6 Control Panel MASTER INTERLOCK MODULE 3840R B. Each six way terminal mounted on the distribution board within the power supply panel is for each interlocked door set. Terminations should be connected as follows:- D1 IN 53W/5 0313 A MALAYSIA 7 8 9 10 Repeat the above wiring for each door in the system. If the master module does not have a slave module or remote override connected to it switch J1 to the ON position. MASTER _________________________________________________________________________________________________ technickon ltd, Unit 7, Boxmend Industrial Estate, Bircholt Road, Parkwood, Maidstone, Kent, ME15 9YG tel: (01622) 673300 fax: (01622) 673311 email: [email protected] web: www. technickon.co.uk -3- DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL _________________________________________________________________________________________________________________________________________________ 3. MAGNETIC LOCK AND PROXIMITY SWITCH D1 ON ON 03 ON J2 J 1 2 3 4 5 6 IN IN D3 + D4 IN 1 2 3 4 5 6 ON IN IN D4 + 1 2 3 4 5 6 ON J4 03 24VDC six core signal cable 1 Amp rated D3 IN 196-6298 PRESS TO RESET D2 + IN + J3 24VDC 0v J6 D1 1 2 3 4 5 6 24VDC DOOR INTERLOCK SYSTEM J5 RS MASTER INTERLOCK MODULE C. When mounting two locks onto a double door the electrical connections should be connected in parallel. + 1 2 3 4 5 6 NAIS TK1 - 24V ATK104 JAPAN T5 CONTROL PANEL 00707 T4 1 2 3 4 5 6 53W/5 FIELD WIRING (To each interlocked door) 0313 A MALAYSIA J1 ON D. Install the proximity switch into the door frame header and connect the NO contacts into terminals 9 and 10. Install the magnet into the door head and check that they align. D2 IN 3840R B. Install the magnetic lock in accordance with the manufactures installation instructions. Connect terminals 7 and 8 into the magnetic lock and ensure that the lock is set to 24vdc. The majority of locks are set to 12vdc when sent out from manufacture. 24vdc 0v A. Run a cable from the master module to the magnetic lock and proximity switch position. 53W/5 E. When using two proximity switches on a double door the electrical connections should be connected in series. Magnetic door lock: 0313 A MALAYSIA Primary door lock for single door use - 250mA @ 24vdc max. 7 8 9 10 (7) + MASTER F. Remove the wires from terminals 9 and 10 and check that continuity is broken when either door is opened and restored when the door is closed, on double doors check that this happens with both door leafs. (8) - (9) (10) + Secondary door lock for duoble door use - 250mA @ 24vdc max. Connect magnets in parallel with a maximum combined current of 500mA @ 24vdc. Door proximity switch: NO contacts when door is open. Connect in series when using two switches on a double door set. NOTE: Use only fail safe locks that fail unlocked in the event of a power failure. _________________________________________________________________________________________________ technickon ltd, Unit 7, Boxmend Industrial Estate, Bircholt Road, Parkwood, Maidstone, Kent, ME15 9YG tel: (01622) 673300 fax: (01622) 673311 email: [email protected] web: www. technickon.co.uk -4- DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL _________________________________________________________________________________________________________________________________________________ 4. SLAVE INTERLOCK MODULE MASTER INTERLOCK MODULE Slave modules enable indicator lights and an override button to be fitted to both sides of the door. This is not always necessary on all systems to have both a master module and a slave module. NA IS TK 1 - 24V AT K1 04 JA PAN T5 A. Run a six core cable form the master module to the slave module. 0 07 07 T4 1 2 3 4 5 6 53W/5 J1 ON 03 13 A MA LAY SIA 53W/5 B. Terminals should be connected as follows:- 031 3 A MAL AYSI A 7 8 9 10 Master Interlock Module Slave Interlock Module (Door 1) Terminal 11 Terminal 12 Terminal 13 Terminal 14 Terminal 15 Terminal 16 (Door 1) – – – – – – MASTER Terminal 1 Terminal 2 Terminal 3 Terminal 4 Terminal 5 Terminal 6 NAIS T5 TK 1 - 24 V AT K 104 J APA N C. When a slave module is connected into a master module ensure that J1 is switched off to extend the override loop. D. 1 2 3 4 5 6 0 0 707 T4 53W/5 0 313 A M ALA YSIA SLAVE SLAVE INTERLOCK MODULE _________________________________________________________________________________________________ technickon ltd, Unit 7, Boxmend Industrial Estate, Bircholt Road, Parkwood, Maidstone, Kent, ME15 9YG tel: (01622) 673300 fax: (01622) 673311 email: [email protected] web: www. technickon.co.uk -5- DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL _________________________________________________________________________________________________________________________________________________ 5. REMOTE OVERRIDE MODULE Remote override modules enable an override button to be connected into the system without indicator lights etc. Remote stop buttons can be connected into the main distribution board using a spare door terminal or into a master module that does not have a slave module connected. MASTER INTERLOCK MODULE 24vdc 0v A. Run a cable with four cores from the distribution panel or a master module to the remote override button position. NAIS T5 T K1 - 2 4V A TK 10 4 J AP AN 0 07 07 T4 1 2 3 4 5 6 53W/5 0 313 A M ALAYS IA D1 IN ON J1 D3 IN D4 IN + ON ON D2 IN IN D3 + 1 2 3 4 5 ON 6 1 2 3 4 5 ON 6 1 2 3 4 5 ON 6 J4 + J2 IN IN D4 + J3 24VDC 0v J 196-6298 PRESS TO RESET D1 1 2 3 4 5 6 Break glass units should be connected in series (NC contacts) into terminals 15 and 16 on the master. J6 RS MASTER J5 3840R 24VDC DOOR INTERLOCK SYSTEM 7 8 9 10 24VDC Remote override Terminal 1 Terminal 2 Terminal 3 Terminal 4 03 031 3 A MAL AYSIA Master Module Terminal 13 (3) – Terminal 14 (4) – Terminal 15 (5) – Terminal 16 (6) – D2 IN 53W/5 03 B. Terminals should be connected as follows when connecting into a master module: + 1 2 3 4 5 6 CONTROL PANEL C. Terminal numbers in brackets are the terminals to use when connecting into a spare terminal in the distribution panel. When a remote override module is connected into a master module ensure that J1 is switched off to extend the override loop. When connecting into a spare door terminal in the power supply panel switch the jumper on the bottom right of the terminal to OFF. 1 2 3 4 1 2 3 4 REMOTE OVERRIDE REMOTE OVERRIDE FIELD WIRING (To each interlocked door) _________________________________________________________________________________________________ technickon ltd, Unit 7, Boxmend Industrial Estate, Bircholt Road, Parkwood, Maidstone, Kent, ME15 9YG tel: (01622) 673300 fax: (01622) 673311 email: [email protected] web: www. technickon.co.uk -6- DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL _________________________________________________________________________________________________________________________________________________ 6. FIRE ALARM CONTROL Terminals 13 and 14 on the distribution board can be used to disable the entire system in the event of a fire alarm condition. Use NO contacts rated at 24vdc that are held closed when the system is healthy. The terminals should open in the event of fire alarm activation. (13) D1 D2 ON ON J6 03 24VDC J2 J D3 IN D4 IN 196-6298 ON 1 2 3 4 5 6 IN IN D3 + ON IN IN D4 + 1 2 3 4 5 6 ON J4 03 RS PRESS TO RESET D2 + 1 2 3 4 5 6 IN + J3 24VDC 0v J5 D1 1 2 3 4 5 6 24VDC DOOR INTERLOCK SYSTEM th 7 GENERATION - AIRSCAPE IN 3840R Normal operation will resume when the contacts are closed and the fire alarm system reset. Fire alarm control: (13,14) NC Contacts that open when alarm is activated. Remove J5 when fitted. 24vdc 0v Ensure J5 (J9 on the large board) is switched off when fitting the fire alarm control. When the fire alarm is operated and the control contacts are opened all power is isolated to the system which will ensure all doors fail safe. NC (14) + 1 2 3 4 5 6 CONTROL PANEL FIELD WIRING (To each interlocked door) _________________________________________________________________________________________________ technickon ltd, Unit 7, Boxmend Industrial Estate, Bircholt Road, Parkwood, Maidstone, Kent, ME15 9YG tel: (01622) 673300 fax: (01622) 673311 email: [email protected] web: www. technickon.co.uk -7- DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL _________________________________________________________________________________________________________________________________________________ 7. REMOTE RESET AND INDICATION The override loop can be set up to latch in the override state. This may be required for a supervisor to be alerted in the event of the button being operated. This can help reduce misuse of the override facility. A key switch with a momentary action should be used for this function, so that the supervisor will hold the reset key and therefore always be alerted in the event of the override buttons being operated. (15) Remote override reset: (15,16) Momentary contacts (NC when operated) Remove J6 when fitted. 24vdc 0v (16) (17) (18) R G Switch J6 (J10 on the large PCB) to OFF when connecting a remote reset switch. ON 03 RS D3 + 1 2 3 4 5 6 ON J3 ON J2 1 2 3 4 5 6 J IN D4 IN IN IN 196-6298 3840R D2 + 1 2 3 4 5 6 IN D3 IN + PRESS TO RESET D1 D2 IN D4 + 1 2 3 4 5 6 ON J4 ON J6 03 24VDC 0v J5 24VDC 24VDC DOOR INTERLOCK SYSTEM 7th GENERATION - AIRSCAPE D1 IN Remote override indication: (17,18) Terminal 18 = 24vdc and Terminal 17 = 0v. Polarity is reversed when override button is operated. This can be used to drive a green LED (system healthy) or a red LED (Override operated) + 1 2 3 4 5 6 CONTROL PANEL FIELD WIRING (To each interlocked door) _________________________________________________________________________________________________ technickon ltd, Unit 7, Boxmend Industrial Estate, Bircholt Road, Parkwood, Maidstone, Kent, ME15 9YG tel: (01622) 673300 fax: (01622) 673311 email: [email protected] web: www. technickon.co.uk -8- DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL _________________________________________________________________________________________________________________________________________________ 8. PUSH TO EXIT BUTTONS PUSH TO EXIT buttons can be fitted if the system needs to operate as a normally locked system. MASTER INTERLOCK MODULE The magnetic locks will release when either button is pressed. NAIS T5 TK1 - 24V ATK104 JAPAN 00707 T4 1 2 3 4 5 6 53W/5 03 13 A MA LAYSIA J1 ON Use monitored door locks with relay output when using PUSH TO EXIT buttons. six core signal cable 1 Amp rated 53W/5 0313 A MALA YSIA 7 8 9 10 MASTER NAIS REF:PE/08 00707 TK1 - 24V ATK104 JAPAN 00707 TK1 - 24V ATK104 JAPAN NAIS PUSH TO EXIT BUTTONS REF:PE/08 + + MASTER SALVE Magnetic door lock: Primary door lock for single door use - 250mA @ 24vdc max. (7) + (8) - (9) (10) + Secondary door lock for duoble door use - 250mA @ 24vdc max. Connect magnets in parallel with a maximum combined current of 500mA @ 24vdc. For door monitoring use the contacts on a monitored magnetic lock. _________________________________________________________________________________________________ technickon ltd, Unit 7, Boxmend Industrial Estate, Bircholt Road, Parkwood, Maidstone, Kent, ME15 9YG tel: (01622) 673300 fax: (01622) 673311 email: [email protected] web: www. technickon.co.uk -9- DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL _________________________________________________________________________________________________________________________________________________ 9. INSTALLATION CHECKLIST BEFORE SWITCHING ON. ü Ensure all magnetic locks have been set to 24vdc. Locks are supplied to operate on 12vdc systems and must be changed to 24vdc during installation. ü Ensure all field wiring has been installed as per the installation instructions. ü Ensure that the correct fuse has been fitted to the fused spur. This door interlock system has a 120db alarm configured that operates when the override facility is operated. It is recommended to follow the following steps to prevent accidental activation of the alarm. 1. On the distribution PCB located in the control panel each door has a jumper located to the bottom right of the terminal. Switch these to ON to isolate the override loop for each door. 2. On the small distribution board (4 doors) switch ON J5 and J6 (On the large distribution boards the jumpers are numbered J9 and J10). J5 (J9) isolates the fire alarm, this should be switched on if no fire alarm control is fitted and J6 (J10) is used to reset the override loop this should only be switched off if the remote reset is used. 3. Switch on the supply to the control panel and the LED next to the white relay should be green, indicating that the system is healthy. 4. Check that all override buttons are twisted out (Reset) and switch each jumper next to each door terminal off to extend the override loop to each door. If when the jumper is switched off the alarm sounds or the LED turns red switch back on and check the field wiring. Carry out this procedure for each door until all jumpers have been switched off. 5. If the fire alarm control has been fitted, switch jumper J5 (J9) off and ensure that the green light is still illuminated. 6. When the system is working correctly, check that the correct doors are interlocked and press each stop button in turn and reset to check operation. When the override button is pressed the alarm should sound and a red light illuminated in the center of the stop button. _________________________________________________________________________________________________ technickon ltd, Unit 7, Boxmend Industrial Estate, Bircholt Road, Parkwood, Maidstone, Kent, ME15 9YG tel: (01622) 673300 fax: (01622) 673311 email: [email protected] web: www. technickon.co.uk - 10 - MASTER 0313 A MALAYSIA 00707 TK1 - 24V ATK104 JAPAN NAIS 53W/5 T4 T4 SLAVE INTERLOCK MODULE SLAVE 1 2 3 4 5 6 00707 7 8 9 10 0313 A MALAYSIA 53W/5 0313 A MALAYSIA 53W/5 DOOR INTERLOCK SYSTEM J1 1 2 3 4 5 6 six core signal cable 1 Amp rated TK1 - 24V ATK104 JAPAN NAIS DOOR INTERLOCK SYSTEM MASTER INTERLOCK MODULE T5 T5 24VDC DOOR INTERLOCK SYSTEM th 7 GENERATION - AIRSCAPE (10) + (9) - (8) - (7) + 24vdc 0v ON J6 ON + 1 2 3 4 5 6 D2 IN ON IN D2 IN 1 2 3 4 5 6 D4 IN + D3 IN IN D4 IN G R NC Remote override indication: (17,18) Terminal 18 = 24vdc and Terminal 17 = 0v. Polarity is reversed when override button is operated. This can be used to drive a green LED (system healthy) or a red LED (Override operated) Remote override reset: (15,16) Momentary contacts (NC when operated) Remove J6 when fitted. Fire alarm control: (13,14) NC Contacts that open when alarm is activated. Remove J5 when fitted. Connect in series when using two switches on a double door set. NO contacts when door is open. Door proximity switch: Connect magnets in parallel with a maximum combined current of 500mA @ 24vdc. Secondary door lock for duoble door use - 250mA @ 24vdc max. Primary door lock for single door use - 250mA @ 24vdc max. Magnetic door lock: FIELD WIRING (To each interlocked door) 1 2 3 4 5 6 + D1 IN D3 PRESS TO RESET + (18) (17) (16) (15) (14) CONTROL PANEL 1 2 3 4 5 6 + J5 ON D1 24VDC 0v J ON 24VDC ON 03 3840R J2 196-6298 J3 03 RS J4 (13) _________________________________________________________________________________________________________________________________________________ DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL 1 2 3 4 5 6 _________________________________________________________________________________________________ technickon ltd, Unit 7, Boxmend Industrial Estate, Bircholt Road, Parkwood, Maidstone, Kent, ME15 9YG tel: (01622) 673300 fax: (01622) 673311 email: [email protected] web: www. technickon.co.uk - 11 - MASTER T4 T4 SLAVE INTERLOCK MODULE SLAVE 0313 A MALAYSIA 00707 TK1 - 24V ATK104 JAPAN NAIS 53W/5 00707 7 8 9 10 0313 A MALAYSIA 53W/5 0313 A MALAYSIA 53W/5 TK1 - 24V ATK104 JAPAN NAIS six core signal cable 1 Amp rated + 1 2 3 4 5 ON 6 + J5 ON D1 J6 (18) 1 2 3 4 5 6 D2 ON + IN IN IN IN D2 1 2 3 4 5 6 D4 IN IN + D3 IN D4 IN G R NC MASTER (10) + (9) - (8) - (7) + + For door monitoring use the contacts on a monitored magnetic lock. Connect magnets in parallel with a maximum combined current of 500mA @ 24vdc. Secondary door lock for duoble door use - 250mA @ 24vdc max. Primary door lock for single door use - 250mA @ 24vdc max. Magnetic door lock: SALVE REF:PE/08 Remote override indication: (17,18) Terminal 18 = 24vdc and Terminal 17 = 0v. Polarity is reversed when override button is operated. This can be used to drive a green LED (system healthy) or a red LED (Override operated) Remote override reset: (15,16) Momentary contacts (NC when operated) Remove J6 when fitted. PUSH TO EXIT BUTTONS FIELD WIRING (To each interlocked door) 1 2 3 4 5 ON 6 + D1 D3 PRESS TO RESET + (16) (17) CONTROL PANEL REF:PE/08 1 2 3 4 5 6 1 2 3 4 5 6 J1 1 2 3 4 5 6 T5 MASTER INTERLOCK MODULE ON (15) 00707 24vdc 0v 24VDC 0v J ON 24VDC T5 24VDC DOOR INTERLOCK SYSTEM th 7 GENERATION - AIRSCAPE 00707 03 3840R J2 196-6298 J3 03 RS J4 Fire alarm control: (13,14) NC Contacts that open when alarm is activated. Remove J5 when fitted. TK1 - 24V ATK104 JAPAN (14) NAIS (13) _________________________________________________________________________________________________________________________________________________ DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL _________________________________________________________________________________________________ technickon ltd, Unit 7, Boxmend Industrial Estate, Bircholt Road, Parkwood, Maidstone, Kent, ME15 9YG tel: (01622) 673300 fax: (01622) 673311 email: [email protected] web: www. technickon.co.uk - 12 - NAIS TK1 - 24V ATK104 JAPAN