six core signal cable 1 Amp rated
+
1
2
3
4
5 ON
6
+
J5
ON
D1
J6
(18)
1
2
3
4
5
6
D2
ON
+
IN
IN
IN
IN
D2
1
2
3
4
5
6
D4
IN
IN
+
D3
IN
D4
IN
G
R
NC
MASTER
(10) +
(9) -
(8) -
(7) +
+
For door monitoring use the contacts
on a monitored magnetic lock.
Connect magnets in parallel with
a maximum combined current of
500mA @ 24vdc.
Secondary door lock for duoble
door use - 250mA @ 24vdc max.
Primary door lock for single
door use - 250mA @ 24vdc max.
Magnetic door lock:
SALVE
REF:PE/08
Remote override indication: (17,18)
Terminal 18 = 24vdc and Terminal 17 =
0v. Polarity is reversed when
override button is operated. This can
be used to drive a green LED (system
healthy) or a red LED (Override
operated)
Remote override reset: (15,16)
Momentary contacts (NC when operated)
Remove J6 when fitted.
PUSH TO EXIT BUTTONS
FIELD WIRING (To each interlocked door)
1
2
3
4
5 ON
6
+
D1
D3
PRESS TO
RESET
+
(16)
(17)
CONTROL PANEL
REF:PE/08
1 2 3 4 5 6
1 2 3 4 5 6
J1
1 2 3 4 5 6
T5
MASTER INTERLOCK MODULE
ON
(15)
00707
24vdc
0v
24VDC
0v
J
ON
24VDC
T5
24VDC DOOR INTERLOCK SYSTEM
th
7 GENERATION - AIRSCAPE
00707
03
3840R
J2
196-6298
J3
03
RS
J4
Fire alarm control: (13,14)
NC Contacts that open
when alarm is activated.
Remove J5 when fitted.
TK1 - 24V
ATK104
JAPAN
(14)
NAIS
(13)
_________________________________________________________________________________________________________________________________________________
DOOR INTERLOCK SYSTEM – INSTALLATION MANUAL