NEXUS Installation V1.07 - 01/11/04 NEXUS Modular Access Control Connections to reader inputs, contact inputs and relay outputs are carried out using plug in terminal blocks for greater control and ease of installation and maintenance. Nexus Power Power for the controller is provided via a separate 12Vdc power supply; two separate power inputs are provided on the motherboard. These being ‘controller’ and ‘auxiliary’ power supplies. The controller supply provides power for the controller logic circuitry whilst the auxiliary supply provides power for readers and relays both input are fused and connection of both supplies to one suitable rated power supply is acceptable. Power supplies Nexus does not carry on board transformer and battery charging facilities. This is provided by external psu’s, which must be suitably rated for both the power requirements of the controller as well as the readers connected to the controller. The section ‘Applying Power’ (page 41), discusses power requirements in greater detail, as well as offering guidance on the estimation of system power requirements. Copyright © 2002 Morley Electronics Page 12 of 51 Document Number CTD1000