SiBE041213E Troubleshooting 4.14 Input Overcurrent Detection Error Code E8 Method of Error Detection An input overcurrent is detected by checking the input current value with the compressor running. Error Decision Conditions The current exceeds about 9.25 ~ 20 A (depending on the model) for 2.5 seconds with the compressor running. (The upper limit of the current decreases when the outdoor temperature exceeds a certain level.) Supposed Causes Power supply voltage is not as specified. Outdoor temperature is out of operation range. Short circuit Power supply voltage is not as specified. Defective outdoor unit PCB Defective compressor Defective power module Troubleshooting Caution Check No.15 Refer to P.95 Be sure to turn off the power switch before connecting or disconnecting connectors, or parts may be damaged. ∗ An input overcurrent may result from wrong internal wiring. If the system is interrupted by an input overcurrent after the wires have been disconnected and reconnected for part replacement, check the wiring again. Check No. 17 Check the installation condition. Check No.17 Refer to P.98 Check No.18 Refer to P.98 Is the power supply voltage fluctuation within ±10% from the rated value? NO Correct the power supply. YES Start operation and measure the input current. Input current flowing above its stop level? NO Replace the outdoor unit PCB. YES Turn off the power and disconnect the harnesses U, V, and W. Check No.15 Check with the inverter analyzer. Any LED off? NO ∗ Inverter analyzer: RSUK0917C YES Correct the power supply or replace the outdoor unit PCB. Turn off the power, and reconnect the harnesses. Turn on the power again and start operation. Check No. 18 Check the discharge pressure. (R18798) Service Diagnosis 76