Download FLY900 AT Command User Guide
Transcript
FLY900 AT Command User Guide Response +S32K:<mode> OK Command AT+S32K=? Response +S32K:(0-1) OK Reference mode: 0:power saving mode is unavailable. 1:power saving mode is available. Note: <mode> would not saved in NV, default value is 0. 11.3 AT+SIND Description Set some status of a system which sends indication automatically ·Indication status of the SIM card. ·Indication status of the call. ·Indication status of the AT command. Command AT+SIND=<IndLevel> Response OK/ERROR Command AT+SIND? Response +SIND:<IndLevel> Command AT+SIND=? Response +SIND:(0-2047)OK 98