3. System Configuration and Wiring
3. System Configuration and Wiring
Wiring to the connector, X4
Wiring to the connector, X5
: Twisted pair)
Negative direction torque
limit input (0 to ±10V)
Select with Pr3.17.
Provide a power supply for the external scale on your part or use the following power
output (250mA or less).
Application
Torque monitor output
Velocity monitor output
42
A, B, Z phase Endoder
signal input
IM
SP
43
I/F of external scale signals
1kΩ
20kΩ 20kΩ 14kΩ
1kΩ
GND
17
(
Power supply output
Remarks
FG
50
41 COM-
ZSP
The functions of the following pin can be changed using parameters.
Input: 8, 9, 26, 27, 28, 29, 30, 31, 32, 33
Output: 10-11, 12, 34-35, 36-37, 38-39, 40
Torque in-limit output
Zero speed detection output 12
11 BRKOFF+
10 BRKOFF40 TLC
At-speed output
VDC
12 to 24V
External brake release output
39 AT-SPEED+
38 AT-SPEED-
ALM-
36
ALM+
Servo-Alarm output
37
35 S-RDY+
34 S-RDY-
NOT
8
31 A-CLR
9 POT
Alarm clear input
Positive direction
over-travel inhibition input
Negative direction
over-travel inhibition input
Control mode
switching input
Speed zero clamp
input
Gain switching input
Servo-ON input
Servo-Ready output
28 DIV1
26 ZEROSPD
32 C-MODE
CL
29 SRV-ON
27 GAIN
INH
30
33
7 COM+
4.7kΩ
X4
–
–
+
10kΩ
16
CCWTL/TRQR
P-ATL/TRQR 16
17
GND
10kΩ
+
20kΩ 20kΩ 14kΩ
GND
N-ATL 18
Wiring example when control mode Pr0.01=5 or Pr3.17=1
Torque command input or
velocity limit input (0 to ±10V)
15
14
SPR/TRQR/SPL
47kΩ
–
+
20kΩ
Divider
20kΩ
47kΩ
47kΩ
47kΩ
CZ
GND
25
19 Z-phase output (open collector)
Z-phase
output
OZ-
OZ+
24
B-phase
output
23
49
OB+
OB-
48
22
OA-
OA+
Connect on to External Scale
X1 to X7 are used for the secondary circuit. To connect these terminals to the primary
power supply (particularly, the 24 VDC power supply for control, and the 24 VDC
power supply for brake), insulation is required.
Do not connect these terminals to the same power supply.
− B24 −
Frame ground
Symbol Connector
Pin No.
Contents
EX5V
1
Supply the power of external
scale or A, B, Z phase encoder.
EX0V
2
Connected to ground of control
circuit.
EXPS
3
/EXPS
4
EXA
5
/EXA
6
EXB
7
/EXB
8
EXZ
9
/EXZ
10
FG
Shell
Serial signal
The transmission / reception
method.
Parallel signal
reception
Correspondence speed :
4Mpps (after quadruple)
Connected with ground terminal
in the servo driver.
Connector (plug): MUF-PK10K-X (by J.S.T. Mfg. Co., Ltd.)
• Caution
1) The manufacturers applicable external scales for this product are as follows.
• Mitutoyo Corp.
• Magnescale Co., Ltd.
For the details of the external scale product, contact each company.
2) Recommended external scale ratio is 1/40 ≤ External scale ratio ≤ 160
If you set up the external scale ratio to smaller value than 50/position loop gain
(Pr1.00 and Pr.1.05), you may not be able to control per 1 pulse unit. Setup of larger scale ratio may result in larger noise.
Remarks
X1 to X7 are used for the secondary circuit. To connect these terminals to the primary
power supply (particularly, the 24 VDC power supply for control, and the 24 VDC
power supply for brake), insulation is required.
Do not connect these terminals to the same power supply.
− B25 −
English
21
A-phase
output
Wiring Example of Torque Control Mode