Download Installation manual
Transcript
Jaw chuck B-Top3. Trouble shooting english 9.2 Trouble shooting table Fault Clamping force is too low Chips penetrate into the chuck. Possible cause Fault correction Corrected by The chuck was not lubricated properly. Lubricate the clamping device with HAINBUCH fat according to maintenance schedule. Specialist Work piece is underdimensioned Move the master jaw by 1 step. Specialist When lathing with Use the guard bushing jaws, the guard bushing was not used. Jaws may not The clamping device is Move the clamping be changed. not in release position. device into release positon. Specialist Specialist Eccentric Concentricity error of Check the concentricity at Specialist dimensional the segmented mandrel the taper of the deviation on segmented mandrel, the work correct if necessary [see piece section »Checking and adjusting the face run and the concentricity«]. Dimensional Contaminated guide deviation on the work piece Disassemble the master Specialist jaws and clean the guide [see section »Cleaning«]. Formal defect Elastic deformation of on the work feedstock that is subject piece to formal defects. After machining the workpiece returns to its original form. Use feedstock with fewer formal defects. If technically justifiably reduce the clamping pressure. Order Hotline +49 [0]7144. 907-333 Specialist 51