Transcript
2 Parameter detailed description P09.40 DI1 status P09.41 DI2 status P09.42 DI3 status P09.43 DI4 status P09.44 DI5 status P09.45 DI6 status P09.46 DI7 status RW US Coding Range Change mode DI1~DI5: 0: off 1: on DI6: 0: off (P09.23≠0) 1: on DI7: 0: off (P09.24≠0) 1: on PT ND ■ ■ PS Actual Display digital input terminals DI1 to DI7 status. When terminal is disconnected with common port, displays 0. When terminal is connected with common port, displays 1. NOTE: 1) 2) When P09.23≠0 (DI6 input mode selects input pulse), P09.45 displays 0. When P09.24≠0 (DI7 input mode selects motor thermistor input or high frequency pulse), P09.46 displays 0. P09.47 Relay1 status P09.48 Relay2 status RW US Coding Range Change mode PT ND ■ ■ PT ND ■ ■ PS 0: off 1: on Actual Display Relay1 and Relay2 status. 0: the relay contact is disconnected. 1: the relay contact is connected. P09.49 DO1 status P09.50 DO2 status RW US Coding Range Change mode PS 0: output 0V 1: output 24V Actual Display digital output terminals DO1, DO2 status. 0:output 0V 1: output 24V NOTE: When P09.31=8 or P09.31=9 (DO2 function is output frequency or PWM output), P09.50 displays 0. 104 HD700 Advanced User Manual